Have a question about the Avanti AV170VFLJM0SS? The AI assistant looks through this manual and shows the pages with the answer.
Same manual for other models
These manuals share their text with this one.
| Avanti AV230VFLJM0SSAV230VFLJM0SS | Same manual | Instruction Manual · 56 pages |
|---|
Key numbers from this manual
As printed in the manual, with metric and US units side by side. The typical range comes from all freezer manuals on this site that print the same figure.
| Fridge factory setting | 41 °F (5 °C)Refrigerator mode | p. 7 |
|---|---|---|
| Fridge adjustment range | 36 °F to 46 °F (2 °C to 8 °C)Refrigeration ModeTypical for freezers: 35 to 46 °F (2 to 8 °C) | p. 8 |
| Freezer factory setting | 0 °F (-18 °C)Freezer modeTypical for freezers: 0 °F (-18 °C) | p. 7 |
| Freezer adjustment range | -11 °F to 3 °F (-24 °C to -16 °C)Freezing ModeTypical for freezers: -11 to 10 °F (-24 to -12 °C) | p. 8 |
| Wait before use | at least two hoursafter moving the freezer | p. 11 |
| Time to cool down | 2 to 3 hoursbefore adding foodat least 4 hoursin hot weather, before stocking fresh or frozen itemsTypical for freezers: 3 to 8 hours | p. 11 |
| Door-open alarm after | more than 120 seconds sooner than mostdoor left openTypical for freezers: 3 to 5 minutes | p. 9 |
| Clearance above | up to 12” needs more space than mostTypical for freezers: 3 to 5.5 in (7.6 to 14 cm) | p. 10 |
| Clearance at the sides | 5 inches (12.7 cm)Typical for freezers: 3 to 5 in (7.6 to 12.7 cm) | p. 10 |
| Clearance behind | 5 inches (12.7 cm)Typical for freezers: 2 to 5 in (5.1 to 12.7 cm) | p. 10 |
| Defrost | frost-free, automatic defrosting functionrefrigerator-freezer | p. 14 |
| Room temperature range | 0 °F to 110 °F (-18 °C to 43 °C)Freezer mode, garage ready41 °F to 110 °F (5 °C to 43 °C)Refrigerator modeTypical for freezers: 50 to 109 °F (10 to 43 °C) | p. 7 |
| Sabbath mode | Yes | p. 9 |
Models in this manual
2 models with ENERGY STAR certified data. Models with the same figures share a row.
| Models | Type | Capacity | Energy use | Ice | Height × width |
|---|---|---|---|---|---|
| AV170VFLJM | Upright Freezer | 17 ft³481 L | 438 kWh/yr10% below US standardabout the same as the median of 105 similar certified models (438 kWh/yr) | None | |
| AV210VFLJM | Upright Freezer | 21 ft³595 L | 493 kWh/yr10% below US standardabout the same as the median of 122 similar certified models (493 kWh/yr) | None |
Avanti AV170VFLJM0SS questions
Answers taken from this manual. Each one links to the page it comes from.
How do I use Quick Freezing mode?
- Press TURBO to activate Quick Freezing mode.
- The temperature automatically changes to -15 °F (-26 °C).
- Press +, -, or TURBO again to exit.
- Alternatively, hold FRZ/REF for 3 seconds to switch to Refrigeration Mode.
- Press FRZ/REF again to return to your previous setting.
Manual: page 9
What should I do about an unpleasant freezer odor?
- Strong-smelling foods. Wrap them tightly.
- Spoiled food. Remove it.
- Interior buildup. Clean the inside.
Manual: page 16
Does this freezer need manual defrosting?
No, it normally defrosts automatically. Minor frost may appear after seasonal or temperature changes.
Manual: page 14
How long should I wait before reconnecting after a power interruption or cleaning?
Wait at least five minutes before reconnecting after an interruption or unplugging for cleaning.
Manual: page 11
How do I prepare the freezer after moving it before adding food?
Wait at least two hours while upright before plugging it in.
- Keep the refrigerator upright for at least two hours before plugging it in.
- Run it for 2 to 3 hours before adding food.
- In hot weather, run it for at least 4 hours before stocking items.
Other brands: LG 24 hours · Midea 24 hours · Other at least 24 hours Compare all
Manual: page 11
How do I level the freezer?
- Place the freezer on a flat, firm floor.
- Rotate the leveling foot left or right until the unit is stable and level.
Manual: page 11
Why is the freezer door temporarily hard to reopen?
A temporary vacuum forms as warm air entering the freezer cools; normal opening should return after 10 to 15 seconds. Pull the handle gently while pressing the edge of the door seal to release pressure sooner.
Manual: page 12
What do the freezer’s E1, E2, E4, E5, and E6 codes mean?
A displayed fault code signals abnormal operation; arrange maintenance as soon as possible, even if cooling continues.
| Code | Indicated fault |
|---|---|
| E1 | Freeze Temperature Sensor Fault |
| E2 | Freezing and Defrosting Sensor Fault |
| E4 | Ambient Temperature Sensor Fault |
| E5 | Communication Fault |
| E6 | Refrigeration Temperature Sensor Fault |
Manual: page 15
Error codes in this manual
| Code | Meaning | What to do | |
|---|---|---|---|
| E1 | Freeze temperature sensor fault. | Arrange maintenance as soon as possible. | p. 15 |
| E2 | Freezing and defrosting sensor fault. | Arrange maintenance as soon as possible. | p. 15 |
| E4 | Ambient temperature sensor fault. | Arrange maintenance as soon as possible. | p. 15 |
| E5 | Communication fault. | Arrange maintenance as soon as possible. | p. 15 |
| E6 | Refrigeration temperature sensor fault. | Arrange maintenance as soon as possible. | p. 15 |
Avanti AV170VFLJM0SS compared with other brands
Freezers from other brands with the most of the same figures in their manuals. Values as printed in each manual.
| Avanti AV170VFLJM0SS | Koolmore KM-RUF-21S | Midea MRU21F5BST | NewAir NFS140SS00 | |
|---|---|---|---|---|
| Fridge factory setting | 41 °F (5 °C) | 41 °F (5 °C) | · | · |
| Fridge adjustment range | 36 °F to 46 °F (2 °C to 8 °C) | 35 to 46 °F (2 to 8 °C) | 2 to 8 °C (36 to 46 °F) | 35℉ to 46℉/2℃ to 8℃ |
| Freezer factory setting | 0 °F (-18 °C) | 0 °F (-18 °C) | -20 °C (-4 °F) | · |
| Freezer adjustment range | -11 °F to 3 °F (-24 °C to -16 °C) | 10 °F to -11 °F (-12 °C, -24 °C) | -12 to -24 °C (10 to -11 °F) | -11℉ to 10℉/-24℃ to -12℃ |
| Time to cool down | 2 to 3 hours | 2 to 3 hours | 2 to 3 hours | 2-3 hours or above 4 hours in summer |
| Door-open alarm after | more than 120 seconds | 300 seconds (5 minutes) | 120 seconds | 5 minutes |
| Clearance above | up to 12” | at least 12 in | · | greater than 12 inches (30.5 cm) |
Similar upright freezer models from other brands
Same layout, capacity within 1.5 ft³ (42 L) of this one. Figures: ENERGY STAR.
| Model | Capacity | Energy use | Ice | Counter depth |
|---|---|---|---|---|
| Midea MRU17F5A | 17 ft³481 L | 438 kWh/yr | None | No |
| Criterion CUF17C1W | 17 ft³481 L | 435 kWh/yr | None | No |
| Element EXUF17CEES | 17 ft³481 L | 435 kWh/yr | None | No |
| GE FUF17DL | 17.3 ft³490 L | 441 kWh/yr | None | No |
| Monogram ZIF301NPN | 16.7 ft³473 L | 579 kWh/yr | Ice maker, door dispenser | No |
| Dacor DRZ30980 | 17.6 ft³498 L | 550 kWh/yr | Ice maker, door dispenser | No |
Similar Avanti freezers
| Avanti AV1081VFK0WUpright Freezer, 11.1 ft³ | Instruction Manual | 20 pages |
|---|---|---|
| Avanti CFC43Q0WG | Operating Instructions | 40 pages |
| Avanti CF10F0W | Operating Instructions | 38 pages |
| Avanti CF101D0W | Operating Instructions | 36 pages |
| Avanti CF24Q0W | Operating Instructions | 24 pages |
| Avanti VM183W | Operating Instructions | 22 pages |