Key numbers from this manual

As printed in the manual, with metric and US units side by side. The typical range comes from all ice maker manuals on this site that print the same figure.

Water supply pressure15 to 80 psi (103 to 552 kPa)Continuous water supplyp. 9
Wait before useapproximately 2 hoursBefore connecting the unit to powerp. 8
Clearance at the sides¼" (6.35 mm) needs less space than mostAt each side for air circulationTypical for ice makers: 1 to 6 in (2.5 to 15.2 cm)p. 9
Clearance behind2" (50.8 mm) needs less space than mostAt the rear for air circulationTypical for ice makers: 3 to 6 in (7.6 to 15.2 cm)p. 9
Room temperature rangeabove 50ºF (10ºC) and below 100ºF (38ºC)Installation areaTypical for ice makers: 50 to 100 °F (10 to 38 °C)p. 9

Avanti IME49U3S-IS questions

Answers taken from this manual. Each one links to the page it comes from.

How do I prevent odors while storing the ice maker long term?
  1. Shut off the water supply at the main water source.
  2. Disconnect the water supply line from the water inlet.
  3. Shut off the electrical supply at the main power source.
  4. Remove remaining ice and water, then dry the storage bin.
  5. Pull off the drainage tube to empty the water.
  6. Leave the door slightly open for air circulation and mold prevention.
  7. Keep the water line and power cord disconnected until reuse.

Manual: page 22

How long should the ice maker stand upright before plugging it in?

Approximately 2 hours, before connecting the unit to the power source.

Manual: page 8

What water pressure does this ice maker need?

At least 15 psig, with static pressure no higher than 80 psig.

Other brands: Scotsman 20 to 80 psi (138 to 552 kPa) · Marvel 20 to 80 psi (138 to 552 kPa) · Whirlpool 30 to 120 psi (207 to 827 kPa) Compare all

Manual: page 9

How do I clean the condenser?

Clean the condenser at least once every six months.

  1. Unplug the ice maker or disconnect power.
  2. Gently remove the lower front louver.
  3. Vacuum dirt and lint from the condenser and compartment using a brush attachment.
  4. Reassemble the lower front louver.
  5. Plug in the ice maker or reconnect power.

Manual: page 20

Why does the ice maker not operate?
  • Power cord disconnected. Plug the ice maker into its power source.
  • Blown fuse. Replace it; if it blows again, contact service for a short-circuit check.
  • Power button set to OFF. Switch the ice maker power button to ON.
  • Storage bin full. Remove some ice and free the ice-full probe.

Manual: page 23

Why does the ice maker stop while making ice?
  • Power supply interrupted. Reconnect the power supply line.
  • Room temperature outside the stated range. Disconnect the unit until the temperature returns within range.
  • Storage bin full. Remove some ice and free the ice-full probe.

Manual: page 24

What should I do if the alarm buzzer sounds?
  1. Turn off the ice maker and water supply.
  2. Remove all ice from the storage bin and wipe up overflowed water.
  3. Check the water trough at the unit’s back and inspect the power source if it is empty.
  4. Check that none of the water lines are kinked.
  5. If corrected, turn the unit on again.
  6. Contact Customer Service if the problem remains.

Manual: page 14

What do the ice maker lights and alarm mean?

These indicators show operating conditions, while the buzzer signals a possible drainage malfunction.

Indicator or soundMeaningWhat happens
BIN FULL (red)Bin full or sensor blockedIce making stops
ICE (green)Ice-making processFlashing means timer-controlled production
HARVEST (yellow)Ice harvest processContinues until bin-full, shutdown, or mode change
Alarm buzzerPossible drainage malfunctionPump, level switch, or drain tube may malfunction

Manual: page 14, page 15

Avanti IME49U3S-IS compared with other brands

Ice Makers from other brands with the most of the same figures in their manuals. Values as printed in each manual.

Avanti IME49U3S-ISScotsman CU0415Other HZB-45AEdgeStar IB121SS
Water supply pressure15 to 80 psi (103 to 552 kPa)15 to 80 psi (100 to 552 kPa)15 to 116 psi (100 to 800 kPa)80 psi (552 kPa)
Wait before useabout 2 hours1 hour4 hoursabout four (4) hours
Clearance at the sides¼" (6.35 mm)1/8 inch or 3 mm5 cm (2 in)1/4 inch (10.2 cm)
Clearance behind2" (50.8 mm)4 inches (100 mm) minimum5CMat least two (2) inches
Room temperature rangeabove 50ºF (10ºC) and below 100ºF (38ºC)50oF or 10oC to 100oF or 38oCabove 50 Fahrenheit and below 90Fahrenheit50 °F -100 °F (10 °C, -73 °C)