GE vs NEFF refrigerators

What GE and NEFF manuals say: typical temperatures, clearances, water filter intervals and ice maker times, plus certified energy use. Based on 121 manuals.

82 GE manuals39 NEFF manuals

Key numbers, typical for each brand

Middle half of the values printed in each brand's refrigerator and fridge freezer manuals.

GENEFF
Fridge factory setting37 °F (3 °C)23 manuals39 °F (4 °C)6 manuals
Recommended fridge temperature37 °F (3 °C)23 manuals39 °F (4 °C)33 manuals
Fridge adjustment range34 to 44 °F (1 to 7 °C)10 manuals36 to 46 °F (2 to 8 °C)30 manuals
Freezer factory setting0 °F (-18 °C)17 manualsnot given
Recommended freezer temperature0 °F (-18 °C)17 manuals0 to 64 °F (-18 to 18 °C)16 manuals
Freezer adjustment range-6 to 6 °F (-21 to -14 °C)9 manuals61 to 75 °F (16 to 24 °C)7 manuals
Water filter replacement6 months24 manualsnot given
Time to cool down24 hours54 manuals12 hours25 manuals
Door-open alarm after2 minutes10 manuals1 to 2 minutes8 manuals
First ice after installation24 hours33 manualsnot given
Clearance above1 in (2.5 cm)36 manualsnot given
Clearance at the sides0.1 to 0.2 in (0.3 to 0.5 cm)35 manuals1.2 to 5.9 in (3 to 15 cm)13 manuals
Clearance behind1 to 1.1 in (2.5 to 2.8 cm)39 manualsnot given
Room temperature range60 to 100 °F (16 to 38 °C)17 manuals50 to 100 °F (10 to 38 °C)5 manuals

What owners ask

Answers from each brand's manuals, by topic.

Other comparisons