Key numbers from this manual

As printed in the manual, with metric and US units side by side. The typical range comes from all freezer manuals on this site that print the same figure.

Freezer adjustment range-12 °C (10.4 °F) to -24 °C (-11.2 °F)Typical for freezers: -11 to 10 °F (-24 to -12 °C)p. 5
Wait before use6 hoursAfter transportation on the freezer’s back or sidep. 6
Clearance above12.7 cm (5 inches)Between the appliance top and adjacent wallsTypical for freezers: 3 to 5.5 in (7.6 to 14 cm)p. 4
Clearance at the sides12.7 cm (5 inches)Between the appliance sides and adjacent wallsTypical for freezers: 3 to 5 in (7.6 to 12.7 cm)p. 4
Clearance behind12.7 cm (5 inches)Between the appliance back and adjacent wallsTypical for freezers: 2 to 5 in (5.1 to 12.7 cm)p. 4
Room temperature range0 °F to 110 °F (-17 °C to 43 °C)Tested operating temperature rangeTypical for freezers: 50 to 109 °F (10 to 43 °C)p. 4
Power outagea few hoursDuring a power failure, with minimal door openingp. 6

Models in this manual

1 model with ENERGY STAR certified data. Models with the same figures share a row.

ModelsTypeCapacityEnergy useIceHeight × width
DUFM101A2WDDUpright Freezer10.1 ft³286 L261 kWh/yr11% below US standard32% less than the median of 79 similar certified models (385 kWh/yr)None

Danby DUFM101A2WDD questions

Answers taken from this manual. Each one links to the page it comes from.

How do I clean the freezer door seal?

Start with a soapy cloth on the sealing area.

  1. Clean the area where the door seals against the cabinet.
  2. Rinse the area with a damp cloth.
  3. Let the area dry.

Manual: page 6

Why is the freezer door hard to open right after closing?

Pressure differences cause this immediately after closing; it is normal and resolves within a few minutes. If it remains especially difficult, wait 5 minutes before trying again.

Manual: page 4

How do I level the freezer?
  1. Turn the leveling leg counter-clockwise until the foot’s top touches the chassis bottom.
  2. Turn it slowly clockwise until the appliance is level.

Manual: page 5

Danby DUFM101A2WDD compared with other brands

Freezers from other brands with the most of the same figures in their manuals. Values as printed in each manual.

Danby DUFM101A2WDDForno FFFFD1738-28LSWood's WUF140SLSummit SCFF1842
Freezer adjustment range-12 °C (10.4 °F) to -24 °C (-11.2 °F)18 °F to 25 °F (-8 °C to -4 °C)-24 °C to -14 °C (-11.2 °F to 6.8 °F)-10 °C to -30 °C(from 14 °F to -22 °F)
Wait before use6 hours6 hours24 hours·
Clearance above12.7 cm (5 inches)5.1 to 10.16 cm (2-4 inches)10 cm (3.9 inches)4” (102mm)
Clearance at the sides12.7 cm (5 inches)5.1 to 10.16 cm (2-4 inches)10 cm (3.9 inches)5” (127mm)
Clearance behind12.7 cm (5 inches)5.1 to 10.16 cm (2-4 inches)7.6cm (3 inches) (7.6 cm)5” (127mm)
Room temperature range0 °F to 110 °F (-17 °C to 43 °C)0 °F to 110 °F (-17 °C to 43 °C)-17 to 43 °C / 0 to 110 °Fabove 61 °F (16 °C) and below 95 °F (35 °C)

Similar upright freezer models from other brands

Same layout, capacity within 1.5 ft³ (42 L) of this one. Figures: ENERGY STAR.

ModelCapacityEnergy useIceCounter depth
Hisense HFU101N1AVE10.2 ft³289 L342 kWh/yrNoneNo
Signature Kitchen Suite SKSCF18019.6 ft³272 L480 kWh/yrIce maker, door dispenserNo
Fisher & Paykel RS2474F310.7 ft³303 L379 kWh/yrIce maker, door dispenserNo
Dacor DRZ189809.5 ft³269 L465 kWh/yrIce maker, door dispenserNo
Avanti AV1081VFK0W11.1 ft³314 L354 kWh/yrNoneNo
Galanz GLF11US2A1611.1 ft³314 L354 kWh/yrNoneNo

Similar Danby freezers

Danby DUFM085A4BSLDDUpright Freezer, 8.5 ft³Owner's Manual24 pages
Danby DUF206E1SSLDBUpright Freezer, 21 ft³Owner's Manual28 pages
Danby DUF140E1WDDUpright Freezer, 13.8 ft³Owner's Manual28 pages
Danby DUF140A1WDBUpright Freezer, 14 ft³Owner's Manual44 pages
Danby DUFM068A1SCDBModel family DUFMOwner's Manual28 pages
Danby DUFM060B1WDBModel family DUFMOwner's Manual28 pages
Danby DUFM043A2WDDModel family DUFMOwner's Manual24 pages
Danby DUF071A3WDBModel family DUFOwner's Manual28 pages
All Danby freezers →