As printed in the manual, with metric and US units side by side. The typical range comes from all refrigerator manuals on this site that print the same figure.
| Fridge adjustment range | five levels between “cool” and “very cold”Normal mode+7 °C to +2 °C (45 °F, 36 °F)Refrigerator cooling rangeTypical for refrigerators: 36 to 46 °F (2 to 8 °C) | p. 21 p. 8 |
|---|---|---|
| Freezer adjustment range | , 10 °C to, 18 °C (50 °F, 64 °F)Freezer compartmentTypical for refrigerators: -9 to 5 °F (-23 to -15 °C) | p. 8 |
| Defrost | automaticrefrigerator compartment | p. 27 |
Dometic RPD190 questions
Answers taken from this manual. Each one links to the page it comes from.
What temperature range can I select in Normal mode?
Normal mode offers five choices, from cool to very cold; one LED means least cooling, five means most, and a middle setting is generally suitable.
Manual: page 21
Why is water leaking inside or underneath the refrigerator?
- Drain blocked. Clean the drain.
- Food obstructs drainage. Keep food away from the rear wall.
- Drain hose split or misrouted. Check the hose behind the appliance.
Manual: page 33
How do I make ice cubes?
- Fill each ice cube tray with water to three quarters full.
- Place the filled trays in the freezer compartment.
- Do not eat ice cubes immediately after removal because they can cause cold burns.
Manual: page 22
Can I install this refrigerator as a freestanding appliance?
No. Install the refrigerator in a fitted cavity, with only its front accessible after installation.
Manual: page 8
How much clearance does installation require around the refrigerator?
No numeric clearance is specified. Leave enough space from walls and objects for air circulation, and keep ventilation vents uncovered.
Manual: page 7
Why is frost forming inside the refrigerator or freezer?
- High ambient temperatures. Lower the temperature control to “1” or “2” for excessive rear-wall frost.
- Humidity. Freezer frost reduces cooling capacity; defrost when the layer exceeds 3 mm.
- Normal condensation. A light frost layer or water droplets can occur after prolonged cooling.