Have a question about the EdgeStar CWB1760FD? The AI assistant looks through this manual and shows the pages with the answer.
Key numbers from this manual
As printed in the manual, with metric and US units side by side. The typical range comes from all wine & beverage cooler manuals on this site that print the same figure.
| Fridge adjustment range | 41 °F to 68 °F (5 °C, 20 °C)right wine zone36 °F to 43 °F (2 °C, 6 °C)left beverage zoneTypical for wine & beverage coolers: 39 to 65 °F (4 to 18 °C) | p. 12 |
|---|---|---|
| Wait before use | at least 24 hoursbefore plugging in after installation or positioning upright | p. 7 |
| Time to cool down | at least 24 hoursbefore storing wines, so the set temperature can be reachedTypical for wine & beverage coolers: 4 to 24 hours | p. 12 |
| Door-open alarm after | more than 60 seconds sooner than mostdoor left openTypical for wine & beverage coolers: 1.6 to 5 minutes | p. 13 |
| Clearance above | 1/4”for service access and ventilationTypical for wine & beverage coolers: 0.3 to 2 in (0.8 to 5.1 cm) | p. 8 |
| Clearance at the sides | 1/4”for service access and ventilationTypical for wine & beverage coolers: 0.3 to 5 in (0.8 to 12.7 cm) | p. 8 |
| Clearance behind | 1-2”for service access and ventilationTypical for wine & beverage coolers: 2 to 5 in (5.1 to 12.7 cm) | p. 8 |
| Defrost | auto-defrostUnder certain conditions, manual defrosting may be requiredautomatically defrostUnder most temperature settings and ambient conditions | p. 17 p. 14 |
| Room temperature range | above 50 °F and below 95 °F (10 °C, 35 °C)installation locationTypical for wine & beverage coolers: 55 to 90 °F (13 to 32 °C) | p. 8 |
| Sabbath mode | Yes | p. 13 |
EdgeStar CWB1760FD questions
Answers taken from this manual. Each one links to the page it comes from.
What temperature ranges can I set for each zone?
The two zones have separate temperature ranges.
| Zone | Settable range |
|---|---|
| Wine, right | 41 °F to 68 °F |
| Beverage, left | 36 °F to 43 °F |
Other brands: Other 5-18℃(40-65℉) · Dometic 5 °C to 22 °C (41 °F to 72 °F) · Summit 34-46 °F (1-8 °C) Compare all
Manual: page 12
How do I adjust the temperature?
- Use the control for the zone you want to change.
- Press Increase Button to raise the setting by 1 degree.
- Press Decrease Button to lower the setting by 1 degree.
- Allow at least 24 hours before storing wines.
Manual: page 12
Why is frost forming inside my wine and beverage cooler?
The unit has auto-defrost, but some conditions may require manual defrosting.
- Humid conditions. Run the cooler at a warmer temperature setting.
- Low ambient temperature. Run the cooler at a warmer temperature setting.
- Frequent door openings. Minimize how often you open the door.
- Frost buildup. Unplug the unit and let the frost melt.
Manual: page 17
How long should the cooler stand before I plug it in?
At least 24 hours, so the compressor’s oils can settle before connection to power.
Other brands: Other 24 hours · Dometic about 2 hours · Liebherr 1 hour Compare all
Manual: page 7
How do I reinstall the door gasket when installing the handle?
- Remove the door gasket from the handle side.
- Fit the handle using two screws and flat washers.
- Replace the door gasket.
- Do not over-tighten the screws, which can damage the handle or stainless steel door.
Manual: page 10
What should I do if frost prevents the door from closing?
Power the unit off until the frost melts, then dry it with a soft absorbent towel.
- Power the unit off.
- Wait for the frost to melt.
- Dry the unit with a soft absorbent towel.
- Never remove frost with a sharp object.
Manual: page 14
How do I defrost the unit before cleaning its interior?
- Disconnect power to the unit.
- Open the door and remove the contents and shelves.
- Wait until the unit defrosts.
- Wipe the interior with a clean cloth.
- Reinsert the shelves and wine.
- Reconnect power to the unit.
Manual: page 15
Why won’t the refrigerator turn on?
Check the power connection and outlet first.
- Not plugged in. Connect the unit to an outlet with sufficient amperage.
- Blown fuse or tripped breaker. Replace the fuse or reset the breaker, then check outlet amperage.
- Power failure. Confirm the unit is plugged in and the outlet has power.
Manual: page 16
EdgeStar CWB1760FD compared with other brands
Wine & Beverage Coolers from other brands with the most of the same figures in their manuals. Values as printed in each manual.
| EdgeStar CWB1760FD | Avallon ABR242SGLH | Summit CL15WC | Whynter BWR-281DZ | |
|---|---|---|---|---|
| Fridge adjustment range | 41 °F to 68 °F (5 °C, 20 °C) | 34 °F to 65 °F (1 °C, 18 °C) | 39 °F to 64 °F (or 4 °C to 18 °C) | Upper Zone : 41ºF-50ºF/5ºC-10ºC |
| Wait before use | at least 24 hours | at least 24 hours | 3 to 5 minutes | about 2 hours |
| Time to cool down | at least 24 hours | at least 24 hours | several hours | · |
| Door-open alarm after | more than 60 seconds | more than three (3) minutes | 5 minutes | more than 60 seconds |
| Clearance above | 1/4” | 1/4” | at least 4” | ¼” (6.35mm) |
| Clearance at the sides | 1/4” | 1/4” | at least 4” | 5 inches (127mm) (12.7 cm) |
| Clearance behind | 1-2” | 1- 2” | at least 4” | 5 inches (127mm) (12.7 cm) |
Similar EdgeStar wine & beverage coolers
| EdgeStar CWR1431TZ | Owner's Manual | 21 pages |
|---|---|---|
| EdgeStar CWR263DZ | Owner's Manual | 21 pages |
| EdgeStar CWR362FD | Owner's Manual | 20 pages |
| EdgeStar CWR1211SZ | Owner's Manual | 18 pages |
| EdgeStar CWR265SZ | Owner's Manual | 12 pages |
| EdgeStar CBR902SG | Owner's Manual | 21 pages |
| EdgeStar CBR1502SG | Owner's Manual | 21 pages |
| EdgeStar CBR1501SSOD | Owner's Manual | 21 pages |