Engel SB30F-N-U questions

Answers taken from this manual. Each one links to the page it comes from.

How much height difference is allowed for separate compressor installation?

Keep the machine part on the same plane; any height difference must stay within ± 100 mm.

Manual: page 9

What battery voltages make the compressor cut out and back in?

The battery monitor uses these compressor protection thresholds.

BatteryCut outCut in
12V9.6V11.5V
24V20.4V23.1V

Manual: page 13

What should I do if battery voltage is lower than 10V?

Charge the battery because its voltage is too low.

Manual: page 15

How large should the intake and exhaust openings be for built-in installation?

Provide separate intake and exhaust openings meeting these minimum dimensions.

OpeningMinimum size
Intake80mm(Min.) x 200mm(Min.)
Exhaust80mm(Min.) x 200mm(Min.)

Manual: page 10

How should I position the fan for built-in installation?

Fan handling depends on which side holds the mechanical part.

  • Mechanical part on the right: Change the fan's position and orientation.
  • Mechanical part on the left: Leave the fan's position and orientation unchanged.

Manual: page 10