Key numbers from this manual
As printed in the manual, with metric and US units side by side. The typical range comes from all ice maker manuals on this site that print the same figure.
| Room temperature range | , 20 F to 120 F (, 29 C to 49 C)Outdoor ambient temperature range for the condenser unitTypical for ice makers: 50 to 100 °F (10 to 38 °C) | p. 18 |
|---|
Follett D1810R-** questions
Answers taken from this manual. Each one links to the page it comes from.
What are the condenser unit’s maximum line-set length and line drop?
The condenser installation limits are:
| Limit | Maximum |
|---|---|
| Line-set length | 75' (22.8 m) |
| Line drop | 15' (4.6 m) |
Manual: page 18
When does a raised condenser unit need S-traps and P-traps?
- For elevations above 13' (4 m), install an S-trap at the midpoint of the rise.
- Install a P-trap at the foot of each vertical riser.
- Add another P-trap for each additional 13' (4 m).
Manual: page 18
Similar Follett ice makers
| Follett D1810R-**Model family D1810R | Service Manual | 54 pages |
|---|---|---|
| Follett D414AS | Installation & Operation Manual | 48 pages |
| Follett D414AS | Service Manual | 48 pages |
| Follett D710A-** | Service Manual | 40 pages |
| Follett D710A-** | Service Manual | 40 pages |
| Follett D710A-** | Service Manual | 40 pages |
| Follett D714A | User Manual | 20 pages |
| Follett D710A-** | User Manual | 16 pages |