Key numbers from this manual

As printed in the manual, with metric and US units side by side. The typical range comes from all refrigerator manuals on this site that print the same figure.

Wait before use24 hoursafter installationp. 11
Door-open alarm after10 min later than mostOuter door ajar or openTypical for refrigerators: 1 to 5 minutesp. 31
Clearance at the sides10 cm (3.9 in) needs more space than mostminimum space around the refrigeratorTypical for refrigerators: 0.7 to 3.1 in (1.8 to 7.9 cm)p. 10
Defrostautomaticp. 24
Room temperature range16 ℃ to 32 ℃installation environmentTypical for refrigerators: 50 to 100 °F (10 to 38 °C)p. 9

Haier HYC-260 questions

Answers taken from this manual. Each one links to the page it comes from.

What temperature range does the refrigerator sensor specify?

2℃ to 8℃ for the sensor in the glycerin bottle.

Manual: page 42, page 43, page 44

Why does the refrigerator not work?
  • Power supply problem. Check that the power supply meets the requirement.
  • Loose plug connection. Inspect the connection between the power plug and socket.
  • Damaged power cord. Check the cord for obvious damage.
  • Low voltage. Check whether the voltage is too low.

Manual: page 35

How does this refrigerator defrost?

Automatic defrost operates through two cycles.

  • Cycle defrost. When the compressor stops, a heater melts evaporator frost without noticeably changing chamber temperature.
  • Forced defrost cycle. HYC-260, HYC-360, HYC-290, HYC-390, and HYC-390F use it when humidity or product moisture creates excess frost; normal operation resumes after thawing.

Manual: page 24

Why is the alarm light flashing and buzzer sounding after restart?
  • Warm products were recently loaded. Wait for cooling to stabilize at 2℃to 6 ℃.
  • Power was recently interrupted. The unit may still be cooling down.
  • The door is not closed properly. Close the door fully.
  • Ambient temperature is too high. Check the surrounding temperature against the designed range.

Manual: page 35

How do I silence an active alarm?

Press Silence to cancel the alarm; the remote alarm continues. If the condition remains, the buzzer returns after 20 minutes.

Manual: page 32

How do I level the refrigerator?
  1. Place the refrigerator on a solid, flat floor.
  2. With a wrench, turn the leveling legs clockwise until they contact the floor.
  3. Check that the refrigerator stays still during operation.

Manual: page 9, page 10

How long should the refrigerator stand before I power it on?

24 hours, after installation, before powering up.

Manual: page 11

Haier HYC-260 compared with other brands

Refrigerators from other brands with the most of the same figures in their manuals. Values as printed in each manual.

Haier HYC-260Summit RefrigeratorHisense HQD20EdgeStar CWR1212SZ
Wait before use24 hoursabout 2 hours4 hoursat least 24 hours
Door-open alarm after10 minmore than 60 seconds2 minutesfive (5) minutes
Clearance at the sides10 cm (3.9 in)5” (127mm)1/2" Each Side (5.1 cm)1/4”
Room temperature range16 ℃ to 32 ℃72º and 78ºF (23º to 26ºC)55 °F (13 °C) to 110 °F (43 °C)between 50 °F and 95 °F (10 °C, 35 °C)

Similar Haier refrigerators

Haier HSW59F18EIMMUser Manual844 pages
Haier HB21FC45Owner's Manual113 pages
Haier HTQ18JABWWOwner's Manual85 pages
Haier HBP18GACRVSOwner's Manual85 pages
Haier HRQ04WNAWWUser Manual61 pages
Haier HSP02WNBUser Manual59 pages
Haier HSP06WNAWWUser Manual56 pages
Haier HBP18GACRVSService Manual37 pages
All Haier refrigerators →