Related manuals

These manuals share their text with this one.

Kucht KR240TFKR240TFShares large sectionsService Manual · 37 pages

Models in this manual

1 model with ENERGY STAR certified data. Models with the same figures share a row.

ModelsTypeCapacityEnergy useIceHeight × width
URBM22SIWPRYBottom Freezer8.4 ft³238 L464 kWh/yr12% below US standard20% more than the median of 41 similar certified models (388 kWh/yr)Ice maker69.7 × 21.3 in177 × 54 cm

ILVE URBM22SIWPRY questions

Answers taken from this manual. Each one links to the page it comes from.

Why will the refrigerator doors not close?
  • Food is blocking the door. Rearrange the food.
  • The door gasket is not seated correctly. Inspect, adjust, or replace it.
  • Worn door hinges. Replace the hinges.

Manual: page 39

Why do the refrigerator’s operating sounds change over time?

The sounds vary with cycles, food volume, and environmental conditions; they are normal when both compartments maintain proper temperatures.

Manual: page 38

Why is the evaporator fan noisy?
  • Irregular fan blade. Have the evaporator cover removed and inspect the fan; replace it if needed.
  • Obstruction near the fan. Inspect the fan area after removing the cover; adjust the fan or clear the obstruction.
  • Excessive fan speed. Check the fan RPM; replace the motor if its speed is too high.

Manual: page 38

How does the ice maker refill after making ice?

The water valve supplies the trays after cubes are ejected, with software controlling how long the valve is energized.

Manual: page 7

What do the ice-maker lights mean?

The light pattern identifies the ice-maker condition:

  • Switch on state: The lamp gradually brightens and dims, indicating the breathing state.
  • Switch off state: The lamp remains dark.
  • Ice full state: The lamp stays on continuously.
  • Drawer removal: The lamp flashes slowly, 0.5 seconds flash once (1HZ).
  • Ice jam: The lamp flashes fast, 1 time 200ms.

Manual: page 16

What do F6 and DR mean on the display?

These messages identify an ambient sensor fault or a door left open too long.

CodeMeaning
F6Ambient Temperature Sensor Error
DRDoor open over 2 minutes

Manual: page 17

Error codes in this manual

CodeMeaningWhat to do
1SIce machine malfunction.Call a professional service engineer to check the appliance.p. 15
2EFreezer fan or motor fault.Call a professional service engineer to check the appliance.p. 15
CECommunication failure between the main and display panels.Call a professional service engineer to check the appliance.p. 15
DRRefrigerator door has been open over two minutes.p. 17
F1This error is unavailable for this model.p. 17
F2Chiller or adapt-zone sensor error.Check the sensor cable, then restart; replace the control board or sensor if needed.p. 15
F3Fridge compartment sensor error.Check the sensor cable, then restart; replace the control board or sensor if needed.p. 15
F4Freezer compartment sensor error.Check the sensor cable, then restart; replace the control board or sensor if needed.p. 15
F5Defrost freezer sensor error.Check the sensor cable, then restart; replace the control board or sensor if needed.p. 15
F6Ambient temperature sensor error.Call a professional service engineer to check the appliance.p. 17
All ILVE error codes →

Similar bottom freezer models from other brands

Same layout, capacity within 1.5 ft³ (42 L) of this one. Figures: ENERGY STAR.

ModelCapacityEnergy useIceCounter depth
Forno FFRBI1704-218.4 ft³238 L464 kWh/yrIce makerNo
Blomberg BRFB1051FFBI28.4 ft³238 L320 kWh/yrNoneNo
Bosch B09IB91NS8.3 ft³235 L388 kWh/yrNoneYes
Gaggenau RB2827058.3 ft³235 L388 kWh/yrNoneYes
Bertazzoni REF24BMBPNB8.6 ft³244 L372 kWh/yrNoneNo
Miele KFN 7795 D8.7 ft³246 L382 kWh/yrIce makerYes

Similar ILVE fridge freezers

ILVE URBM22SIWPRYBottom Freezer, 8.4 ft³User Manual26 pages
ILVE URFC36SNWPRYUser Manual29 pages
All ILVE fridge freezers →