Have a question about the KitchenAid Fridge Freezer? The AI assistant looks through this manual and shows the pages with the answer.
Key numbers from this manual
As printed in the manual, with metric and US units side by side. The typical range comes from all fridge freezer manuals on this site that print the same figure.
| Water filter replacement | 6 to 9 months longer than mostModels without a water filter status light, depending upon usageTypical for fridge freezers: 6 months | p. 15 |
|---|---|---|
| Replacement filter | 4392857NL300 and L500 replacement cartridges | p. 27 |
| Water supply pressure | 30 to 120 psi (207 to 827 kPa)water supply | p. 28 |
| Time to cool down | 24 hoursnewly installed refrigerator, to cool completelyTypical for fridge freezers: 4 to 24 hours | p. 25 |
| First ice after installation | 24 hoursafter ice maker hookup, for ice production72 hoursafter ice maker installation, for full ice productionTypical for fridge freezers: 24 hours | p. 23 |
| Ice production | 70 to 120 cubes every 24 hoursafter the refrigerator has cooledapproximately 7 to 9 batches in a 24-hour periodNormal ice production | p. 23 p. 16 |
| Defrost | automaticrefrigerator automatic defrost cycle | p. 23 |
| Power outage | 24 hourspower outage of 24 hours or less, keep doors closed | p. 22 |
KitchenAid Fridge Freezer questions
Answers taken from this manual. Each one links to the page it comes from.
When should I replace the water filter?
Replace the cartridge when the indicator reaches Change (red) or water flow noticeably decreases.
- With a status light, replace it at Change (red) or after noticeable flow reduction.
- Without a status light, replace the cartridge every 6 to 9 months, depending upon usage.
- Replace it sooner if dispenser or ice-maker water flow decreases noticeably.
Other brands: LG every 6 months · Midea 150 days · Samsung about 6 months Compare all
Manual: page 15
Why is water or ice leaking from the dispenser?
- The container moves away too soon. Hold it under the chute 2 to 3 seconds after releasing the lever.
- An ice cube holds the trap door open. Remove the cube.
- Air remains in the filter lines. Flush again; normal use may clear it within 24 to 72 hours.
Manual: page 25
Why won’t my refrigerator run?
- Unplugged power cord. Connect it to a grounded 3 prong outlet.
- Blown fuse or tripped breaker. Replace the fuse or reset the circuit breaker.
- Control set to OFF. Check the refrigerator or freezer control setting.
- Automatic defrost cycle. Check again after 30 minutes.
- Dirty condenser coils. Clean the condenser coils.
Manual: page 23
Why is my refrigerator temperature too warm?
- Blocked air vents. Move objects away from vents in either compartment.
- Frequent door opening. Remove items together and close the door promptly.
- Large recent food load. Allow several hours to return to normal temperature.
- Incorrect controls. Check the control settings for surrounding conditions.
- Digital-control reset needed. Turn the unit OFF, then ON; call for service if cooling does not return.
Manual: page 25
How do I turn the ice maker on or off?
- Style 1: Lower the wire shutoff arm to ON; lift it to OFF and listen for the click.
- Style 2: Slide the control left to ON, or right to OFF.
Manual: page 16
How long until the first ice, and what should I do with it?
Allow 24 hours for the first batch, then discard the first three batches.
Other brands: LG about 48 hours · Midea about 8 hours · Samsung 24 hours Compare all
Manual: page 17
How thick can a flat custom wood panel be?
A flat custom wood panel can be a maximum of ¹⁄₄ in. (6.35 mm) thick.
Manual: page 10
What weight limits apply to custom raised door panels?
The maximum weights for raised panel inserts are:
| Panel | Maximum weight |
|---|---|
| Refrigerator door panel | 25 lbs. (9.98 kg) |
| Freezer door panels combined | 18 lbs. (6.80 kg) |
Manual: page 10
KitchenAid Fridge Freezer compared with other brands
Fridge Freezers from other brands with the most of the same figures in their manuals. Values as printed in each manual.
| KitchenAid Fridge Freezer | LG LHSXS2706 | Whirlpool W10750538A | Electrolux Fridge Freezer | |
|---|---|---|---|---|
| Water filter replacement | 6 to 9 months | every 6 months | 6 months | 6 to 9 months |
| Replacement filter | 4392857 | LT1000P, LT1000PC, LT1000PCS or ADQ747935** | P9RFWB2L, part #EDR2RXD1/EDR2RXD1B | RG-100 |
| Water supply pressure | 30 to 120 psi (207 to 827 kPa) | 20 to 120 psi (138 to 827 kPa) | 30 to 120 psi (207 to 827 kPa) | 30 to 100 psi (207 to 690 kPa) |
| Time to cool down | 24 hours | up to 24 hours | 24 hours | at least 8 to 12 hours |
| First ice after installation | 24 hours | about 12 to 24 hours | 24 hours | within 24 hours |
| Ice production | 70 to 120 cubes every 24 hours | 70 to 182 cubes in a 24-hour period | about 3 lbs (1.4 kg) of ice per day | 4 to 4.5 pounds |
| Power outage | 24 hours | · | · | · |
Similar KitchenAid fridge freezers
| KitchenAid W10668652A | User Manual | 132 pages |
|---|---|---|
| KitchenAid W10537977A | User Manual | 129 pages |
| KitchenAid W11218735A | Use & Care Guide | 86 pages |
| KitchenAid Fridge Freezer Owner's Manual | Owner's Manual | 72 pages |
| KitchenAid Fridge Freezer Owner's Manual | Owner's Manual | 72 pages |
| KitchenAid W11504344 | Owner's Manual | 72 pages |
| KitchenAid Fridge Freezer Use & Care Guide | Use & Care Guide | 64 pages |
| KitchenAid Fridge Freezer Use & Care Guide | Use & Care Guide | 64 pages |