Key numbers from this manual

As printed in the manual, with metric and US units side by side. The typical range comes from all refrigerator manuals on this site that print the same figure.

Fridge adjustment range35°to 40 °F (4 °C)all undercounter refrigeratorsTypical for refrigerators: 36 to 46 °F (2 to 8 °C)p. 6
Wait before useat least 24 hoursafter laying the unit on its side or back, before start-upp. 5
Clearance behind2”rear wall clearance for air circulation and temperature regulation2" (5.1 cm)between the unit and its rear wallTypical for refrigerators: 1.5 to 3 in (3.8 to 7.6 cm)p. 5
Defrostautomaticfactory default defrost cyclep. 6
Room temperature range65° and 80 °F (27 °C)ambient temperature during installationTypical for refrigerators: 50 to 100 °F (10 to 38 °C)p. 5

Maxx Cold MXCR27U-FBHC questions

Answers taken from this manual. Each one links to the page it comes from.

Why is water collecting inside or underneath the refrigerator?
  • Drain tube is loose or disconnected. Reconnect the tube between the evaporator housing and condensate pan.
  • Tube is outside the pan. Check that the tube remains inside the condensate evaporator drain pan.
  • Drainage is obstructed or the unit is uneven. Level the refrigerator and clear every drain line.

Manual: page 9

How do I clean the door gasket to prevent mold and mildew?
  1. Clean the gasket with warm, soapy water.
  2. Avoid full-strength cleaning products, which can make the gasket brittle.
  3. Do not scrape the gasket with sharp tools or knives.

Manual: page 9

How much space should I leave behind the refrigerator?

At least 2” from the rear wall is needed for air circulation and temperature regulation.

Manual: page 5

What room conditions are specified for installation?

Less than 65% humidity and an ambient temperature between 65° and 80 °F are specified.

Other brands: LG +10 - +32 · Samsung between 10 °C and 43 °C (50 °F, 109 °F) · Marvel 55 °F to 100 °F (13 °C to 38 °C) Compare all

Manual: page 5

How often does the refrigerator defrost automatically?

Every 6 hours, the unit stops for evaporator defrosting and restarts at terminal temperature or after 20 minutes.

Manual: page 6

Why does the evaporator freeze up?
  • Blocked airflow. Clear obstructions inside the cabinet and around the evaporator air inlets and outlets.
  • Incorrect automatic defrost setup. Program the cycle so the evaporator defrosts and the fans circulate cooling air.

Manual: page 5, page 6

What do the refrigerator’s alarm messages mean, and when do they clear?

Probe faults, temperature limits, and digital-input conditions produce these alarm messages.

  • Probe faults. For P1 or P2, check connections; the alarm clears after normal probe operation resumes.
  • Temperature limits. HA and LA clear once the temperature returns to normal.
  • Digital-input condition. EA and CA with iF=bL clear after the digital input is disabled.

Manual: page 7

Maxx Cold MXCR27U-FBHC compared with other brands

Refrigerators from other brands with the most of the same figures in their manuals. Values as printed in each manual.

Maxx Cold MXCR27U-FBHCLG URNTC2306NSummit RefrigeratorHisense HQD20
Fridge adjustment range35°to 40 °F (4 °C)33 °F to 46 °F (1 °C to 8 °C)36 °F to 43 °F (2 °C, 6 °C)45 °F to 34 °F or from 7 °C to 1 °C
Wait before useat least 24 hours24 hoursabout 2 hours4 hours
Clearance behind2”2” (50 mm) (2 in)5” (127mm)2" (5 cm)
Room temperature range65° and 80 °F (27 °C)55 °F (13 °C) and 110 °F (43 °C)72º and 78ºF (23º to 26ºC)55 °F (13 °C) to 110 °F (43 °C)