Key numbers from this manual

As printed in the manual, with metric and US units side by side. The typical range comes from all refrigerator manuals on this site that print the same figure.

Fridge factory setting39 Fahrenheit degreerefrigerating chamber, first power-on settingTypical for refrigerators: 37 to 39 °F (3 to 4 °C)p. 45
Freezer factory setting0 Fahrenheit degreesfreezing chamber, first power-on settingTypical for refrigerators: 0 °F (-18 °C)p. 45
Water filter replacement150 days more often than mostThe filter icon lights to prompt replacementTypical for refrigerators: 6 monthsp. 47
Door-open alarm after120sA refrigerator or freezer door remains openTypical for refrigerators: 1 to 5 minutesp. 46

Midea HC-957WEN questions

Answers taken from this manual. Each one links to the page it comes from.

How do I remove the built-in water filter?
  1. Shut off the water supply.
  2. Squeeze the filter mounting box, then detach its lid.
  3. Rotate the filter counterclockwise to unplug it.
  4. Fasten the mounting cover upward.

Manual: page 39

How do I change the refrigerator or freezer temperature?
  • Press REF. TEMP, then press REF.TEMP to cycle through refrigerator settings.
  • Press FRZ. TEMP, then press FRZ. TEMP to cycle through freezer settings.

Manual: page 46

What temperatures are set when the refrigerator first powers on?

39 Fahrenheit degree for the refrigerating chamber and 0 Fahrenheit degrees for the freezing chamber.

Manual: page 45

Where should I place the refrigerator for ventilation?

Choose a location with easy ventilation so heat can dissipate, performance can improve, and energy use can decrease.

Manual: page 13

How do I level a refrigerator that rocks?

Adjust the footing until the refrigerator is level and placed steadily.

Manual: page 14

How do I remove the refrigerator door seal?
  1. Open the refrigerator door.
  2. Pull the door seal out of the door liner groove.

Manual: page 25

Where are the refrigerator’s defrost components located?

The service pages identify these positions around the freezing-chamber evaporator.

ComponentLocation
Defrost sensorTop of the evaporator
Defrost heaterBottom of the evaporator
Defrosting fuseAttached to the evaporator

Manual: page 30

Error codes in this manual

CodeMeaningWhat to do
CAMainboard and ice maker communication failure.Check whether main control terminal CN9 and ice maker terminal CN6 are securely connected.p. 49
E0Ice maker fault.Check and reseat terminals, inspect for foreign matter, and verify the ice maker terminal.p. 47
E1Refrigerating chamber temperature sensor fault.Check and reseat terminals, inspect contacts, then replace the main control board if necessary.p. 47
E2Freezing chamber temperature sensor fault.Check terminals and sensor resistance, then replace the main control board if necessary.p. 47
E3Variable chamber temperature sensor fault.Check terminals and sensor resistance, then replace the control board or wiring harness.p. 48
E4Refrigerating chamber defrost sensor fault.Check terminals and sensor resistance, then replace the control board or wiring harness.p. 48
E5Freezing chamber defrost sensor fault.Check terminals and sensor contacts, then replace the main control board.p. 48
E6Communication failure.Check and reseat terminals, inspect contacts, then replace the control boards or main wire.p. 48
E7Ambient temperature sensor fault.Check terminals and wiring, then replace the control board or hinge temperature sensor.p. 48
E8Variable chamber defrost sensor fault.Check terminals and sensor resistance, then replace the control board or wiring harness.p. 49
E9Freezing chamber high temperature alarm.Check the door seal, prolonged power loss, compressor operation, and E2 maintenance procedures.p. 49
EEIce maker sensor circuit fault.Check and reseat the ice maker sensor terminal and inspect it for foreign matter.p. 49
EFWater tank is incorrectly installed.Check the relevant connectors and whether the tank base is installed correctly.p. 49
EHAmbient humidity sensor circuit fault.Check terminals and wiring, then replace the control board or humidity sensor.p. 49
All Midea error codes →

Midea HC-957WEN compared with other brands

Refrigerators from other brands with the most of the same figures in their manuals. Values as printed in each manual.

Midea HC-957WENWhirlpool W10439277CFrigidaire RefrigeratorKitchenAid REFRIGERADOR.......27
Fridge factory setting39 Fahrenheit degree37 °F (3 °C)37 °F (3 °C)37 °F (3 °C)
Freezer factory setting0 Fahrenheit degrees0 °F (-18 °C)0 °F (-18 °C)0 °F (-18 °C)
Water filter replacement150 daysat least every 6 monthsevery 6 monthsat least every 6 months
Door-open alarm after120s5 minutes5 minutes or more5 minutes

Similar Midea refrigerators

Midea 16131000A51956Model family 16131Instruction Manual73 pages
Midea HQ-567WENInstruction Manual15 pages
Midea 16131000A43643User Manual119 pages
Midea MRM33S9ASLUser Manual68 pages
Midea MDRC207FZF01APUser Manual20 pages
Midea MERP27FGE30EUUser Manual20 pages
Midea WHD-113FUser Manual19 pages
Midea 16131000A46805User Manual18 pages
All Midea refrigerators →