As printed in the manual, with metric and US units side by side. The typical range comes from all fridge freezer manuals on this site that print the same figure.
| Fridge factory setting | 39℉Refrigerator compartment, first power-onTypical for fridge freezers: 37 to 39 °F (3 to 4 °C) | p. 15 |
|---|---|---|
| Fridge adjustment range | 1 °C/34 °F to 7 °C/44 °FRefrigerator compartmentTypical for fridge freezers: 34 to 46 °F (1 to 8 °C) | p. 15 |
| Freezer factory setting | 0℉Freezer compartment, first power-onTypical for fridge freezers: 0 °F (-18 °C) | p. 15 |
| Freezer adjustment range | -22 °C/-7 °F to -14 °C/7 °FFreezer compartmentTypical for fridge freezers: -8 to 6 °F (-22 to -14 °C) | p. 15 |
| Water supply pressure | 40 to 100 psi (276 to 690 kPa)Water supply inlet | p. 8 |
| Door-open alarm after | 2 minutesafter power-on if the door is not closedTypical for fridge freezers: 1.4 to 3 minutes | p. 16 |
| Defrost | No Frost | p. 34 |
| Sabbath mode | Yes | p. 16 |
Models in this manual
2 models with ENERGY STAR certified data. Models with the same figures share a row.
| Models | Type | Capacity | Energy use | Ice | Height × width |
|---|---|---|---|---|---|
| MRF29D9 | Bottom Freezer | 28.9 ft³818 L | 743 kWh/yr10% below US standard2% more than the median of 202 similar certified models (727 kWh/yr) | Ice maker, door dispenser | 69.9 × 35.8 in178 × 91 cm |
| MRF29D9B | Bottom Freezer | 29.3 ft³830 L | 782 kWh/yr5% below US standard7% more than the median of 200 similar certified models (733 kWh/yr) | Ice maker, door dispenser | 69.8 × 35.8 in177 × 91 cm |
Midea MRF29D9BST questions
Answers taken from this manual. Each one links to the page it comes from.
How do I install the water filter?
- Pull out the small drawer in the center.
- Put the filter into its compartment and turn it 90° clockwise to lock it.
Manual: page 11
How do I replace the water filter?
- Press the filter knob and turn it 90° counterclockwise to release the filter.
- Remove the water tray beneath the filter and empty any overflow.
- Fit the new filter using the installation steps.
Manual: page 11
What are the refrigerator and freezer default temperatures and adjustment ranges?
Temperature changes take effect after the display panel is locked.
| Compartment | Default | Setting range |
|---|---|---|
| Refrigerator | 39℉ | 1 °C/34 °F to 7 °C/44 °F |
| Freezer | 0℉ | -22 °C/-7 °F to -14 °C/7 °F |
Other brands: LG 33 °F to 43 °F (1 °C to 7 °C) · Samsung 34 °F (1 °C ) and 44 °F (7 °C) · Whirlpool 33 °F to 45 °F (0 °C to 7 °C) Compare all
Manual: page 15
How do I get rid of refrigerator odors?
- Strong-smelling food. Wrap it tightly and keep an open box of baking soda inside; replace it every three months.
- Spoiled food. Check whether any food has spoiled.
- Dirty interior. Clean the interior.
Manual: page 32
Why does the refrigerator not operate?
- Unplugged refrigerator. Push the plug fully into the outlet.
- Sabbath mode. Hold REF ICE MAKER and LOCK for 3s to exit it.
- Blown fuse or tripped breaker. Replace the fuse or reset the breaker.
Manual: page 32
Why does the refrigerator run for long periods or cycle frequently?
- Hot weather or frequent door openings. This is normal.
- Large food loads. Longer operation is normal after adding substantial amounts of food.
- Hot food added. Added heat raises the interior temperature, so the compressor runs longer to restore the set temperature.
Manual: page 32
What does TRAY FULL mean on the dispenser?
AutoFill is disabled. Clean the water tray before using AutoFill again; manual ice and water dispensing still works.
Manual: page 21
Error codes in this manual
| Code | Meaning | What to do | |
|---|---|---|---|
| C9 | Ice making chamber temperature sensor failure | Contact maintenance personnel to ensure normal refrigerator use. | p. 17 |
| CA | Communication failure between main and ice making control boards | Contact maintenance personnel to ensure normal refrigerator use. | p. 17 |
| CC | Ice making chamber defrost sensor failure | Contact maintenance personnel to ensure normal refrigerator use. | p. 17 |
| E0 | Freezer ice maker initialization failure | Contact maintenance personnel to ensure normal refrigerator use. | p. 17 |
| E1 | Refrigerating chamber temperature sensor failure | Contact maintenance personnel to ensure normal refrigerator use. | p. 17 |
| E2 | Freezer chamber temperature sensor failure | Contact maintenance personnel to ensure normal refrigerator use. | p. 17 |
| E5 | Freezer chamber defrost sensor failure | Contact maintenance personnel to ensure normal refrigerator use. | p. 17 |
| E6 | Communication failure between display and main control boards | Contact maintenance personnel to ensure normal refrigerator use. | p. 17 |
| E7 | Ambient temperature sensor failure | Contact maintenance personnel to ensure normal refrigerator use. | p. 17 |
| EE | Sensor beneath the freezer ice maker failure | Contact maintenance personnel to ensure normal refrigerator use. | p. 17 |
| EH | Humidity sensor failure | Contact maintenance personnel to ensure normal refrigerator use. | p. 17 |
| EP | Freezer ice maker cannot turn over ice | Contact maintenance personnel to ensure normal refrigerator use. | p. 17 |
| F4 | Sensor beneath the refrigerating ice maker failure | Contact maintenance personnel to ensure normal refrigerator use. | p. 17 |
| F5 | Refrigerating ice maker cannot turn over ice | Contact maintenance personnel to ensure normal refrigerator use. | p. 17 |
| F6 | Refrigerating ice maker initialization failure | Contact maintenance personnel to ensure normal refrigerator use. | p. 17 |
| P4 | Spill sensor failure | Contact maintenance personnel to ensure normal AutoFill use. | p. 22 |
| P6 | Dispenser RX ice making board communication error | Contact maintenance personnel to ensure normal AutoFill use. | p. 22 |
| P7 | Dispenser TX ice making board communication error | Contact maintenance personnel to ensure normal AutoFill use. | p. 22 |
| P8 | Dispenser RX ultrasonic board communication error | Contact maintenance personnel to ensure normal AutoFill use. | p. 22 |
| P9 | Dispenser TX ultrasonic board communication error | Contact maintenance personnel to ensure normal AutoFill use. | p. 22 |
| PA | Dispenser upper limit switch failure | Contact maintenance personnel to ensure normal AutoFill use. | p. 22 |
| Pb | Dispenser lower limit switch failure | Contact maintenance personnel to ensure normal AutoFill use. | p. 22 |
| PC | Dispenser cup pressing switch failure | Contact maintenance personnel to ensure normal AutoFill use. | p. 22 |
Midea MRF29D9BST compared with other brands
Fridge Freezers from other brands with the most of the same figures in their manuals. Values as printed in each manual.
| Midea MRF29D9BST | LG LFC20760 | Whirlpool W10750538A | Haier QHE16HYPFS | |
|---|---|---|---|---|
| Fridge factory setting | 39℉ | 4 | 37 °F (3 °C) | 37 °F (3 °C) |
| Fridge adjustment range | 1 °C/34 °F to 7 °C/44 °F | 32 °F to 47 °F or 0 °C to 8 °C | 33 °F to 45 °F (0 °C to 7 °C) | 34 °F to 42 °F (1 °C to 6 °C) |
| Freezer factory setting | 0℉ | 4 | 0 °F (-18 °C) | 0 °F (-18 °C) |
| Freezer adjustment range | -22 °C/-7 °F to -14 °C/7 °F | -6 °F to 8 °F or -21 °C to -13 °C | -5 °F to 5 °F (-21 °C to -15 °C) | -6 °F to 6 °F (-21 °C to -14 °C) |
| Water supply pressure | 40 to 100 psi (276 to 690 kPa) | between 20 and 120 p.s.i | 30 to 120 psi (207 to 827 kPa) | 40 to 120 psi (276 to 827 kPa) |
| Door-open alarm after | 2 minutes | 1 minute | 5 minutes | more than 3 minutes |
Similar bottom freezer models from other brands
Same layout, capacity within 1.5 ft³ (42 L) of this one. Figures: ENERGY STAR.
| Model | Capacity | Energy use | Ice | Counter depth |
|---|---|---|---|---|
| Thor Kitchen TRF3628FFD | 28.9 ft³818 L | 743 kWh/yr | Ice maker, door dispenser | No |
| Zline RSM-W-36-BS | 28.9 ft³818 L | 743 kWh/yr | Ice maker, door dispenser | No |
| LG LRFCS29D6 | 28.8 ft³816 L | 643 kWh/yr | Ice maker | No |
| GE GNE29GMK | 28.8 ft³816 L | 653 kWh/yr | Ice maker | No |
| Frigidaire GRFN2853A | 28.7 ft³813 L | 652 kWh/yr | Ice maker | No |
| GE Profile PGD29BYT | 28.7 ft³813 L | 681 kWh/yr | Ice maker | No |
Similar Midea fridge freezers
| Midea MRF29D2ASTBottom Freezer, 29.3 ft³ | User Manual | 52 pages |
|---|---|---|
| Midea MRF27I4BSTBottom Freezer, 26.5 ft³ | User Manual | 72 pages |
| Midea MRF29D3ABBBottom Freezer, 29.3 ft³ | User Manual | 85 pages |
| Midea MRF29D6ASTBottom Freezer, 29.3 ft³ | User Manual | 88 pages |
| Midea MRF27I6BSTBottom Freezer, 26.5 ft³ | User Manual | 92 pages |
| Midea MRF29D6ASTBottom Freezer, 29.3 ft³ | User Manual | 76 pages |
| Midea MRF23I5ASTModel family MRF2 | User Manual | 72 pages |
| Midea MRF23I7ASTModel family MRF2 | User Manual | 72 pages |