Have a question about the Other ETERNAL43? The AI assistant looks through this manual and shows the pages with the answer.
Key numbers from this manual
As printed in the manual, with metric and US units side by side. The typical range comes from all portable / rv refrigerator manuals on this site that print the same figure.
| Fridge adjustment range | -4℉ to 68℉ (-20℃ to 20℃)temperature control-20 °C to 20 °C(-4 °F to 68 °F)ETERNAL43Typical for portable & rv fridges: 36 to 54 °F (2 to 12 °C) | p. 5 p. 9 |
|---|---|---|
| Wait before use | more than 6 hoursafter receiving and unpacking, with the door opening at the top | p. 5 |
| Clearance behind | greater than 100mmGap between the compressor cooling holes and other objectsTypical for portable & rv fridges: 0.2 to 4.3 in (0.5 to 10.9 cm) | p. 5 |
| Control lock | Yes | p. 4 |
Other ETERNAL43 questions
Answers taken from this manual. Each one links to the page it comes from.
What temperature range can I set on the ETERNAL43?
-20 °C to 20 °C (-4 °F to 68 °F).
Other brands: Dometic 0 °C (32 °F) to 12 °C (53.6 °F) · Avanti position "1” to “5” · Whynter -8 °F to 50 °F (-22 °C, 10 °C) Compare all
Manual: page 9
Why is the refrigerator not running?
- Power supply is off. Turn on the power supply.
- Voltage is too low. Check the supply voltage.
- Connection is loose or poor. Check the connections.
- Fuse is blown. Check the fuse.
- Refrigerator is turned off. Check that it is turned on.
Manual: page 8
How much ventilation space does the compressor cooling area need?
Greater than 100mm between the compressor cooling holes and other objects.
Other brands: Dometic 10 mm to 25 mm (0.4 in, 1 in) · Haier 2" (50mm) (5.1 cm) · Avanti 5 inches (12.7 cm) Compare all
Manual: page 5
How long should the refrigerator stand before I power it on?
More than 6 hours, with the door opening at the top.
Other brands: Summit 24 HOURS · Whynter about 4 hours · Vitrifrigo at least 3 hours Compare all
Manual: page 5
What should I do when an error code appears?
Unplug the refrigerator after correcting the abnormality, then reconnect it to restart cooling.
- Correct the abnormal condition indicated by the displayed error code.
- Unplug the power supply.
- Plug the power supply in again.
- Wait 1 minute for compressor cooling mode to restart.
Manual: page 9
What do error codes E1, E2, and E5 mean?
E1 indicates low input voltage, E2 indicates fan overcurrent, and E5 indicates high module temperature.
| Code | Meaning | Manual solution |
|---|---|---|
| E1 | Input voltage too low | Check voltage; adjust battery |
| E2 | DC fan overcurrent | Check the cooling fan |
| E5 | Module temperature too high | Move to a ventilated place |
Manual: page 9
How long should I wait before powering on the refrigerator?
Wait more than 6 hours after unpacking before powering on, with the door opening at the top.
Manual: page 5
What do the H, M and L battery protection levels do?
The factory setting is M, while H is recommended in a car.
| Level | 12V OFF / ON | 24V OFF / ON |
|---|---|---|
| H | 11.1V OFF, 12.4V ON | 24.3V OFF, 25.7V ON |
| M | 10.4V OFF, 11.7V ON | 22.8V OFF,24.2V ON |
| L | 9.6V OFF, 10.9V ON | 21.3V OFF,22.7V ON |
Manual: page 6
Error codes in this manual
| Code | Meaning | What to do | |
|---|---|---|---|
| E0 | Temperature sensor is damaged. | Check or replace the temperature sensor. | p. 9 |
| E1 | Input voltage is too low. | Check the input voltage and adjust the battery. | p. 9 |
| E2 | DC fan overcurrent protection is activated. | Check the cooling fan. | p. 9 |
| E3 | Abnormal compressor startup protection is activated. | Restart the refrigerator after 30 minutes. | p. 9 |
| E4 | Abnormal compressor speed protection is activated. | Adjust the compressor working mode. | p. 9 |
| E5 | Module temperature is too high. | Move the refrigerator to a ventilated place to lower module temperature. | p. 9 |
Other ETERNAL43 compared with other brands
Portable & RV Fridges from other brands with the most of the same figures in their manuals. Values as printed in each manual.
| Other ETERNAL43 | Whynter FMC-350XP | InVision Portable / RV Refrigerator | Aspenora AS-BPR35S | |
|---|---|---|---|---|
| Fridge adjustment range | -4℉ to 68℉ (-20℃ to 20℃) | -8 °F to 50 °F (-22 °C, 10 °C) | 1 °C to 7 °C (34 °F to 45 °F) | -4 °F (-20 °C) to 50 °F(10 °C) |
| Wait before use | more than 6 hours | about 4 hours | 2 hours | 24 hours |
| Clearance behind | greater than 100mm | at least 6 inches (15.2 cm) | 25.4mm (1.0”) | 4” |
Similar Other portable & rv fridges
| Other SRAE0722 | Service Manual | 44 pages |
|---|---|---|
| Other YT-A-15X | Instruction Manual | 16 pages |
| Other F40C4TMP | User Manual | 12 pages |