Have a question about the Setpower Portable / RV Refrigerator? The AI assistant looks through this manual and shows the pages with the answer.
Key numbers from this manual
As printed in the manual, with metric and US units side by side. The typical range comes from all portable / rv refrigerator manuals on this site that print the same figure.
| Fridge adjustment range | -20 °C(-4 °F) to +20 °C(68 °F)Temperature setting for the refrigerator20 °C(68 °F) to -20 °C(-4 °F)Adjustable temperature settingTypical for portable & rv fridges: 36 to 54 °F (2 to 12 °C) | p. 6 |
|---|
Setpower Portable / RV Refrigerator questions
Answers taken from this manual. Each one links to the page it comes from.
How do I change the portable refrigerator’s temperature?
Press + or - to set the temperature from -20 °C(-4 °F) to 20 °C(68 °F).
Other brands: Dometic 0 °C (32 °F) to 12 °C (53.6 °F) · Other -7.6 °F to 50 °F(-22 °C to +10 °C) · Avanti position "1” to “5” Compare all
Manual: page 6
How do I switch between Celsius and Fahrenheit?
- In standby, hold + and - together for 3 seconds.
- Briefly press ON/OFF to cycle to the F/C function.
- Press + or - to switch between Celsius and Fahrenheit.
Manual: page 6
What do Setpower error codes E1 through E6 mean?
They identify low-voltage, fan, compressor, temperature, or thermal-head faults.
| Code | Meaning |
|---|---|
| E1 | Low-battery protection activates; input voltage below setting. |
| E2 | Fan fault, short circuit, or frequent starts and stops. |
| E3 | Compressor motor cannot start, or system pressure difference is too large. |
| E4 | Compressor speed too low because the refrigeration system is overloaded. |
| E5 | Compressor module temperature is above 100 °C or below - 10 °C. |
| E6 | Thermal head open circuit or short circuit. |
Manual: page 10
How do I power the cooler from a 12V or 24V source?
Error codes in this manual
| Code | Meaning | What to do | |
|---|---|---|---|
| E1 | Low battery protection activates because input voltage is below the configured threshold. | p. 10 | |
| E2 | Fan malfunction, short circuit, or repeated starting and stopping. | p. 10 | |
| E3 | Compressor motor cannot start because of blockage or excessive system pressure difference. | p. 10 | |
| E4 | Compressor speed is too low because the refrigeration system is overloaded. | p. 10 | |
| E5 | Compressor control module temperature is outside its safe operating range. | p. 10 | |
| E6 | Thermal head has an open or short circuit fault. | p. 10 |
Similar Setpower portable & rv fridges
| Setpower RV45D | User Manual | 16 pages |
|---|