Key numbers from this manual

As printed in the manual, with metric and US units side by side. The typical range comes from all portable / rv refrigerator manuals on this site that print the same figure.

Fridge adjustment range-20 °C(-4 °F) to +20 °C(68 °F)Temperature setting for the refrigerator20 °C(68 °F) to -20 °C(-4 °F)Adjustable temperature settingTypical for portable & rv fridges: 36 to 54 °F (2 to 12 °C)p. 6

Setpower Portable / RV Refrigerator questions

Answers taken from this manual. Each one links to the page it comes from.

How do I change the portable refrigerator’s temperature?

Press + or - to set the temperature from -20 °C(-4 °F) to 20 °C(68 °F).

Other brands: Dometic 0 °C (32 °F) to 12 °C (53.6 °F) · Other -7.6 °F to 50 °F(-22 °C to +10 °C) · Avanti position "1” to “5” Compare all

Manual: page 6

How do I switch between Celsius and Fahrenheit?
  1. In standby, hold + and - together for 3 seconds.
  2. Briefly press ON/OFF to cycle to the F/C function.
  3. Press + or - to switch between Celsius and Fahrenheit.

Manual: page 6

What do Setpower error codes E1 through E6 mean?

They identify low-voltage, fan, compressor, temperature, or thermal-head faults.

CodeMeaning
E1Low-battery protection activates; input voltage below setting.
E2Fan fault, short circuit, or frequent starts and stops.
E3Compressor motor cannot start, or system pressure difference is too large.
E4Compressor speed too low because the refrigeration system is overloaded.
E5Compressor module temperature is above 100 °C or below - 10 °C.
E6Thermal head open circuit or short circuit.

Manual: page 10

How do I power the cooler from a 12V or 24V source?
  1. Use the DC input with a 12V or 24V direct-current power source.
  2. Check that the polarity is correct.
  3. If using a cigarette plug, verify that the power supply is sufficient.
  4. Use one power supply, not a power strip, two-way splitter, or DC extension cord.

Manual: page 6, page 9

Error codes in this manual

CodeMeaningWhat to do
E1Low battery protection activates because input voltage is below the configured threshold.p. 10
E2Fan malfunction, short circuit, or repeated starting and stopping.p. 10
E3Compressor motor cannot start because of blockage or excessive system pressure difference.p. 10
E4Compressor speed is too low because the refrigeration system is overloaded.p. 10
E5Compressor control module temperature is outside its safe operating range.p. 10
E6Thermal head has an open or short circuit fault.p. 10
All Setpower error codes →

Similar Setpower portable & rv fridges

Setpower RV45DUser Manual16 pages
All Setpower portable & rv fridges →