Key numbers from this manual

As printed in the manual, with metric and US units side by side. The typical range comes from all fridge freezer manuals on this site that print the same figure.

Fridge factory setting5℃ (41 ℉ )At first use or after a power failure, refrigeratorTypical for fridge freezers: 37 to 39 °F (3 to 4 °C)p. 18
Fridge adjustment range2℃ (36 ℉ ) to 8℃ (46 ℉ )Adjustable refrigerator temperature rangeTypical for fridge freezers: 34 to 46 °F (1 to 8 °C)p. 18
Freezer factory setting-18℃ (0 ℉ )At first use or after a power failure, freezerTypical for fridge freezers: 0 °F (-18 °C)p. 18
Freezer adjustment range-15℃ (5 ℉ ) to -25℃ (-13 ℉ )Adjustable freezer temperature rangeTypical for fridge freezers: -8 to 6 °F (-22 to -14 °C)p. 18
Door-open alarm after60 seconds sooner than mostDoor left openTypical for fridge freezers: 1.4 to 3 minutesp. 21
Clearance above30cm (12 inches) (30.5 cm) needs more space than mostspace above the refrigeratorTypical for fridge freezers: 1 to 3.9 in (2.5 to 9.9 cm)p. 6
Clearance behind1cm (1/2 inch) (5.1 cm) needs less space than mostspace at the rear of the applianceTypical for fridge freezers: 1 to 2 in (2.5 to 5.1 cm)p. 6
DefrostNo FrostFreezer systemp. 19
Vacation modeYesThe appliance has a Holiday functionp. 18

Smeg CB2485U questions

Answers taken from this manual. Each one links to the page it comes from.

What temperatures does the appliance use initially?

On first use or after a power failure, the appliance starts at these compartment temperatures.

CompartmentInitial temperature
Refrigerator5℃ (41 ℉ )
Fresh zone0℃ (32 ℉ )
Freezer-18℃ (0 ℉ )

Manual: page 18

What temperature ranges can I set for the refrigerator and freezer?

The refrigerator and freezer controls cycle through these temperature limits.

CompartmentAdjustable range
Refrigerator2℃ (36 ℉ ) to 8℃ (46 ℉ )
Freezer-15℃ (5 ℉ ) to -25℃ (-13 ℉ )

Manual: page 18

How do I prevent odors when leaving the appliance unused?
  1. Unplug the appliance.
  2. Clean the appliance before storage.
  3. Leave the doors slightly ajar to prevent mildew and unpleasant odors.

Manual: page 20

The refrigerator is not running. What should I check?
  • No power reaches the appliance. Check that the appliance has power.
  • A fuse has blown. Check the household fuses and the fuse in the plug.
  • The appliance was turned off. Check that it has not been turned off.
  • The outlet is faulty. Test it by plugging in another electrical appliance.

Manual: page 21

What cavity dimensions does the built-in refrigerator require?

Use these minimum cavity dimensions for the built-in installation.

DimensionUnit sizeCavity size
Width21 1/4 in (540 mm)Minimum 22 1/8 in (560 mm)
Height6941/64 in (1769 mm)6923/65 in to 6927/32 in (1771 mm to 1774 mm)
Depth2121/32 in (550 mm)Minimum 223/64 in (minimum 560 mm)

Manual: page 8

How do I provide ventilation for the built-in installation?

Create airflow below, above, and behind the cabinet run.

  1. Use the supplied grill or an air vent with at least 31 in2 (200 cm2) cross-sectional area.
  2. Make a 17.64 in (448 mm) wide by 2.6 in (55 mm) high opening below the refrigerator.
  3. Place the ventilation grill inside the cabinet-base opening.
  4. Fasten the grill with 4 screws, placing 1 screw in each corner.
  5. Create an air passageway in the cabinet run's top section.
  6. Leave rear cabinet space so cool air can reach the condenser.

Manual: page 7

How do I reshape a compressed door seal after reversing the door?

Close the door, then reshape the compressed seal with a hair dryer.

  1. Hold the hair dryer about 10 cm / 4 inches from the appliance.
  2. Warm the seal until it expands and fills the gap around the door.
  3. Allow the seal and door to cool before touching them.
  4. Check that the seal stays in position.

Manual: page 11

What power supply does the refrigerator require?

AC 120V/60Hz, with a properly grounded 3-prong plug and 15A fuse.

Manual: page 6

How can I disconnect power from the appliance?

Pull the plug from the outlet or switch off the breaker.

Manual: page 6

Error codes in this manual

CodeMeaningWhat to do
2EFreezer fan or motor fault.Call a professional service technician to check the appliance.p. 18
ECCommunication fault between main and display panels.Call a professional service technician to check the appliance.p. 18
F1Fridge evaporator sensor fault.Call a professional service technician to check the appliance.p. 18
F2Fresh zone sensor fault.Call a professional service technician to check the appliance.p. 18
F3Fridge compartment sensor fault.Call a professional service technician to check the appliance.p. 18
F4Freezer compartment sensor fault.Call a professional service technician to check the appliance.p. 18
F5Defrosting sensor fault.Call a professional service technician to check the appliance.p. 18
All Smeg error codes →

Smeg CB2485U compared with other brands

Fridge Freezers from other brands with the most of the same figures in their manuals. Values as printed in each manual.

Smeg CB2485UMidea MRF27I4BSTWhirlpool W10750538AHaier QHE16HYPFS
Fridge factory setting5℃ (41 ℉ )37 °F (03 °C)37 °F (3 °C)37 °F (3 °C)
Fridge adjustment range2℃ (36 ℉ ) to 8℃ (46 ℉ )01 to 07 °C/34 to 44 °F33 °F to 45 °F (0 °C to 7 °C)34 °F to 42 °F (1 °C to 6 °C)
Freezer factory setting-18℃ (0 ℉ )-04 °F (-20 °C)0 °F (-18 °C)0 °F (-18 °C)
Freezer adjustment range-15℃ (5 ℉ ) to -25℃ (-13 ℉ )-22 to -14 °C/-07 to 07 °F-5 °F to 5 °F (-21 °C to -15 °C)-6 °F to 6 °F (-21 °C to -14 °C)
Door-open alarm after60 secondsmore than 2 minutes5 minutesmore than 3 minutes
Clearance above30cm (12 inches) (30.5 cm)>1"(25mm) (2.5 cm)¹⁄₂" (1.25 cm)1” (25 mm) (1 in)
Clearance behind1cm (1/2 inch) (5.1 cm)>2"(50mm) (5.1 cm)1" (2.54 cm)2” (5 cm) (2 in)