Key numbers from this manual

As printed in the manual, with metric and US units side by side. The typical range comes from all refrigerator manuals on this site that print the same figure.

Fridge factory setting38 °F/3 °Crefrigerator compartmentTypical for refrigerators: 37 to 39 °F (3 to 4 °C)p. 18
Fridge adjustment range36 °F/2 °C to 43 °F/6 °Crefrigerator compartment16 to 99 °F/-9 to 37 °Crefrigerator temperature display rangeTypical for refrigerators: 36 to 46 °F (2 to 8 °C)p. 18 p. 23
Freezer factory setting0 °F/-18 °Cfreezer compartmentTypical for refrigerators: 0 °F (-18 °C)p. 18
Freezer adjustment range-11 °F/-24 °C to 11 °F/-12 °Cfreezer compartmentTypical for refrigerators: -9 to 5 °F (-23 to -15 °C)p. 18
Water supply pressure20 to 80 psi (138 to 552 kPa)Required water pressure for the icemaker.p. 23
Wait before useapproximately 2 hoursbefore connecting after transportationp. 8
Door-open alarm aftermore than 60 secondsdrawer left openTypical for refrigerators: 1 to 5 minutesp. 20
Clearance above4” (102mm) needs more space than mostfree-standing installation¼” (6.35mm)built-in installationTypical for refrigerators: 1 to 3.9 in (2.5 to 9.9 cm)p. 8
Clearance at the sides5” (127mm) needs more space than mostfree-standing installation, each side¼” (6.35mm)built-in installation, each sideTypical for refrigerators: 0.7 to 3.1 in (1.8 to 7.9 cm)p. 8
Clearance behind5” (127mm) needs more space than mostfree-standing installation2” (51mm)built-in installationTypical for refrigerators: 1.5 to 3 in (3.8 to 7.6 cm)p. 8
Defrostautomaticnormal operating conditionsp. 19
Room temperature rangeabove 44 °F (7 °C) and below 90 °F (32 °C)installation areaTypical for refrigerators: 50 to 100 °F (10 to 38 °C)p. 4
Power outagea few hoursmost power failuresp. 21
Sabbath modeYesp. 18
Control lockYesactivates automatically after 2 minutes or longer without touching a keyp. 18

Summit ASDR1524 questions

Answers taken from this manual. Each one links to the page it comes from.

What temperature settings are available for the refrigerator and freezer?

Factory settings and adjustable ranges are shown below.

CompartmentFactory settingAdjustable range
Freezer0 °F/-18 °C-11 °F/-24 °C to 11 °F/-12 °C
Refrigerator38 °F/3 °C36 °F/2 °C to 43 °F/6 °C

Other brands: LG from 0 °C to 6 °C (32 °F, 43 °F) · Samsung 7 °C and 1 °C (45 °F, 34 °F) · Midea 8℃, 6℃, 4℃, 2℃ Compare all

Manual: page 18

Why won't the refrigerator run?
  • It is not connected to power. Connect the appliance.
  • The appliance is turned off. Switch on the appliance.
  • The circuit breaker tripped or fuse blew. Switch on the breaker or replace the fuse.

Manual: page 22

How do I start the ice maker and prepare its first ice?

Turn on the water supply and place the ice maker’s bail arm in ON.

  1. Let the ice maker produce ice for 1-2 days.
  2. Discard the first 2-3 batches to clear impurities from the water system.

Manual: page 19

How long should the refrigerator stand before I connect power?

Leave the refrigerator upright for approximately 2 hours before connecting it to the power source.

Other brands: LG 24 hours · Midea 24 hours · Samsung 2 hours Compare all

Manual: page 8

How do I silence the open-drawer alarm?

Press the POWER key once to stop the audible alarm; the alarm sounds after a drawer remains open 60 seconds.

Manual: page 20

What should I do during a power outage?

Keep the drawers closed as much as possible; most outages lasting a few hours should not affect the appliance temperature. Protect the contents if the outage lasts longer.

Manual: page 21

Summit ASDR1524 compared with other brands

Refrigerators from other brands with the most of the same figures in their manuals. Values as printed in each manual.

Summit ASDR1524Whirlpool RefrigeratorFrigidaire RefrigeratorHaier A2FE635CBJ
Fridge factory setting38 °F/3 °C37 °F (3 °C)37 °F (3 °C)5 °C (41 °F)
Fridge adjustment range36 °F/2 °C to 43 °F/6 °C33 °F to 45 °F (0 °C to 7 °C)+34 °F / +1 °C to +44 °F / +7 °C2 °C to 8 °C (36 °F, 46 °F)
Freezer factory setting0 °F/-18 °C0 °F (-18 °C)0 °F (-18 °C)‐18 °C (64 °F)
Freezer adjustment range-11 °F/-24 °C to 11 °F/-12 °C-5 °F to 5 °F (-21 °C to -15 °C)-6 °F / -21 °C to +6 °F / -15 °C‐24 °C to ‐16 °C (75 °F, 61 °F)
Water supply pressure20 to 80 psi (138 to 552 kPa)30 to 120 psi (207 to 827 kPa)30 to 100 psi (207 to 690 kPa)·
Wait before useabout 2 hours··at least 6 hours
Door-open alarm aftermore than 60 seconds5 minutes5 minutes or more3 minutes

Similar Summit refrigerators

Summit RDF24SSModel family RDFOperating Instructions16 pages
Summit FF1511SSUser Manual64 pages
Summit FF1074User Manual18 pages
Summit ECD806Instruction Manual25 pages
Summit FD106WInstruction Manual25 pages
Summit ECD806Instruction Manual24 pages
Summit FD106WInstruction Manual24 pages
Summit SCR-600BLInstruction Manual12 pages
All Summit refrigerators →