Key numbers from this manual
As printed in the manual, with metric and US units side by side. The typical range comes from all compact refrigerator manuals on this site that print the same figure.
| Clearance above | no additional air spacebuilt-in installationdoes not require additional air spacebuilt-in installationTypical for compact & mini fridges: 2 to 5 in (5.1 to 12.7 cm) | p. 8 |
|---|---|---|
| Clearance at the sides | no additional air spacebuilt-in installationdoes not require additional air spacebuilt-in installationTypical for compact & mini fridges: 2 to 5 in (5.1 to 12.7 cm) | p. 8 |
| Clearance behind | does not require additional air spacebuilt-in installationTypical for compact & mini fridges: 3 to 5 in (7.6 to 12.7 cm) | p. 8 |
| Space to open the doors | 1/4" (6.4 mm)between two units for unobstructed simultaneous door opening | p. 9 |
| Defrost | automatic | p. 33 |
| Room temperature range | 50 °F (10 °C) and 100 °F (38 °C)operating ambient temperatureTypical for compact & mini fridges: 55 to 100 °F (13 to 38 °C) | p. 6 |
Models in this manual
1 model with ENERGY STAR certified data. Models with the same figures share a row.
| Models | Type | Capacity | Energy use | Ice | Height × width |
|---|---|---|---|---|---|
| UHBV524-IS01A | Compact Refrigerator | 5.2 ft³147 L | 275 kWh/yr10% below US standard3% more than the median of 604 similar certified models (268 kWh/yr) | NoneCounter depth | 33.7 × 23.6 in86 × 60 cm |
U-Line UHBV524-IS01A questions
Answers taken from this manual. Each one links to the page it comes from.
How do I verify and fine-tune the refrigerator’s actual temperature?
Use a water-filled bottle and thermometer to measure the cabinet temperature before making a small adjustment.
- Partly fill a plastic, nonbreakable bottle with water.
- Put an accurate thermometer inside the bottle.
- Securely tighten the bottle cap.
- Place the bottle in the area you want to test for 24 hours.
- Do not open the refrigerator during the test.
- After 24 hours, measure the water and adjust temperature control slightly if needed.
Manual: page 34
Why is frost or condensation forming on my unit?
- Poor door sealing. Make sure the door closes and seals properly to prevent frost on internal surfaces.
- Excessive humidity. Moisture on external surfaces will dissipate as humidity levels decrease.
Manual: page 33
Is water dripping into the drain pan normal?
Yes, water may drip or run into the drain pan during the automatic defrost cycle.
Manual: page 33
Why is my compact refrigerator not cooling?
A dirty condenser, restricted airflow, or an inactive condenser fan can overheat the compressor; check airflow, cleanliness, and fan operation.
Manual: page 45
How much space is needed between two units for both doors to open?
Use the spacing that matches the installation and door hardware.
- Hinge-by-hinge integrated models: 13/16" (22 mm), with more space possibly needed for handles.
- Stainless steel models with the standard handle: 4-9/16" (116 mm) for both doors to open to 90° together.
- Maintain 1/4" (6.4 mm) between units for unobstructed simultaneous door swing.
Manual: page 9
What do U-Line error codes E0 through E9 mean?
Error codes in this manual
| Code | Meaning | What to do | |
|---|---|---|---|
| E0 | Upper door is open. | p. 48 | |
| E1 | Zone thermistor is open. | p. 48 | |
| E2 | Evaporator thermistor is open. | p. 48 | |
| E3 | Thermistor 3 is open. | p. 49 | |
| E4 | Thermistor 4 is open. | p. 49 | |
| E5 | Zone thermistor is shorted. | p. 49 | |
| E6 | Evaporator thermistor is shorted. | p. 49 | |
| E7 | Thermistor 3 is shorted. | p. 49 | |
| E8 | Thermistor 4 is shorted. | p. 49 | |
| E9 | Lower door is open. | p. 49 | |
| P1 | Pump circuit is open. | p. 49 |
U-Line UHBV524-IS01A compared with other brands
Compact & Mini Fridges from other brands with the most of the same figures in their manuals. Values as printed in each manual.
| U-Line UHBV524-IS01A | LG LRONC0605V | Other BC-85B | Hisense LMS044M6RVE | |
|---|---|---|---|---|
| Space to open the doors | 1/4" (6.4 mm) | 39 5/8" (1008 mm) | 160° | 180° |
| Room temperature range | 50 °F (10 °C) and 100 °F (38 °C) | 55 °F (13 °C) to 110 °F (43 °C) | below 50° or above 90° | 12.8 to 43.3 C (55-110 F ) |
Similar compact refrigerator models from other brands
Same layout, capacity within 1.5 ft³ (42 L) of this one. Figures: ENERGY STAR.
| Model | Capacity | Energy use | Ice | Counter depth |
|---|---|---|---|---|
| Marvel MPWC424-SG31A | 5.2 ft³147 L | 249 kWh/yr | None | Yes |
| Avanti AR52T3SB | 5.2 ft³147 L | 256 kWh/yr | None | No |
| Thermador T24UR915LS | 5.2 ft³147 L | 274 kWh/yr | None | No |
| XO XOU24RDO | 5.2 ft³147 L | 275 kWh/yr | None | No |
| Thor Kitchen TBR24US | 5.2 ft³147 L | 275 kWh/yr | None | No |
| Zline RBSO-ST-24 | 5.2 ft³147 L | 257 kWh/yr | None | No |
Similar U-Line compact & mini fridges
| U-Line U-29RB-00ACompact Refrigerator, 3.3 ft³ | User Manual | 37 pages |
|---|---|---|
| U-Line ADA24RBCompact Refrigerator, 5.3 ft³ | User Manual | 59 pages |
| U-Line U-2224RGLINT-00BCompact Refrigerator, 4.7 ft³ | User Manual | 61 pages |
| U-Line DR124 | User Manual | 47 pages |
| U-Line RE124 | User Manual | 45 pages |
| U-Line RE115 | User Manual | 43 pages |
| U-Line URBV418-IS01A | User Manual | 58 pages |
| U-Line URBV418-IG01A | User Manual | 58 pages |