Key numbers from this manual

As printed in the manual, with metric and US units side by side. The typical range comes from all fridge freezer manuals on this site that print the same figure.

Fridge factory setting41 °F (5 °C) warmer than mostFirst time switching on, fridge compartmentTypical for fridge freezers: 37 to 39 °F (3 to 4 °C)p. 12
Fridge adjustment range35 °F (2℃) to 46 °F ( 8℃) (2 °C, 8 °C)Fridge temperature adjustmentTypical for fridge freezers: 34 to 46 °F (1 to 8 °C)p. 12
Freezer adjustment range5 °F(-15)℃ to-15 °F(-25℃) (-15 °C, -26 °C)Freezer temperature adjustmentTypical for fridge freezers: -8 to 6 °F (-22 to -14 °C)p. 12
Door-open alarm after60 seconds sooner than mostdoor left openTypical for fridge freezers: 1.4 to 3 minutesp. 17
Clearance aboveat least 100mm needs more space than mosttall housing unit installationTypical for fridge freezers: 1 to 3.9 in (2.5 to 9.9 cm)p. 19
Defrostno frost systemproductNo Frostfreezer systemp. 16
Vacation modeYesHoliday functionp. 12

Models in this manual

1 model with ENERGY STAR certified data. Models with the same figures share a row.

ModelsTypeCapacityEnergy useIceHeight × width
VEFBF2411RISLBottom Freezer11.5 ft³326 L480 kWh/yr11% below US standard22% more than the median of 148 similar certified models (395 kWh/yr)Ice maker73.2 × 23.4 in186 × 59 cm

Verona VEFBF2411RISL questions

Answers taken from this manual. Each one links to the page it comes from.

Why is my refrigerator not running?
  • No power. Check the supply, house fuses, plug fuse, and socket with a different appliance.
  • The fridge is switched off. Check that the fridge has not been turned off.

Manual: page 17

Why is my refrigerator not cooling properly?
  • Overloading. Check that the appliance is not overloaded.
  • Temperature setting. Check that the thermostat has an appropriate temperature setting.
  • Poor door closure. Check that the doors close properly.
  • Dust or rear-wall contact. Clean the rear cooling system and keep it from touching the wall.
  • Insufficient ventilation. Check for enough ventilation at the side and rear walls.

Manual: page 17

How do I turn the ice maker on or off, or start manual de-icing?
  1. Press Ice Maker Switch briefly to change the ice maker’s operating state.
  2. For manual de-icing, hold Ice Maker Switch for 10 seconds while powered on.

Manual: page 14

What do the ice maker lights and flashing signals mean?

These patterns describe the ice maker’s operating and fault states.

StateLight behavior
OnFades in, then fades out, breathing
OffLight is not on
Ice fullAlways on
Drawer removalSlow flash, 0.5 seconds once (1HZ)
Ice jamFast flash, 1 time, 200ms

Manual: page 14

How much ventilation clearance is needed above the fridge in a tall housing unit?

At least 100mm of ventilation clearance is needed above the fridge.

Other brands: Midea 3" (7.6 cm) · Whirlpool 1½" (3.81 cm) · GE 1" (25 mm) Compare all

Manual: page 19

How do I restore a door seal after reversing the door?

Use a hair dryer to expand the seal and close the gap, keeping it approximately 10cm away.

  1. Close the door before warming the seal.
  2. Warm the seal with a hair dryer until it fills the gap.
  3. Keep the hair dryer approximately 10cm from the appliance.
  4. Let the seal and door cool before touching them.
  5. Check that the seal remains in position.

Manual: page 22

How long does the warranty cover the door gasket?

Gaskets are covered for ninety (90) days from the product’s installation date.

Manual: page 24

Do I need to manually defrost the freezer?

No, the freezer uses a No Frost system, so routine manual defrosting is not needed during normal use.

Manual: page 16

Why is excessive ice forming in my freezer?
  • Poor door sealing. Check the door’s resistance, then inspect the seal for kinks, debris, or damage.
  • Misfitted décor door. Have the installer check the décor door if it is not fitted correctly.
  • Unresolved seal damage. Contact Customer Care to arrange seal replacement.

Manual: page 18

What do the refrigerator fault codes F2, F3, F4, F5, 2E, and CE mean?

These display codes indicate sensor, fan, or communication faults; a professional service engineer should check the appliance.

CodeMeaning
F2Chiller zone sensor
F3Fridge compartment sensor
F4Freezer compartment sensor
F5Defrosting sensor
2EFreezer fan or motor fault
CEMain and display panel communication fault

Manual: page 13

Why is the freezer temperature display flashing and sounding an alarm?

Press any button to cancel the voice alarm. The freezer-temperature digit flashes after temperature rises to >77 °F (-1 °C), until it falls below <77 °F (1 °C).

Manual: page 13

Error codes in this manual

CodeMeaningWhat to do
2EFreezer fan or motor faultCall a professional service engineer to check the appliance.p. 13
CECommunication fault between main and display panelsCall a professional service engineer to check the appliance.p. 13
F2Chiller zone sensor faultCall a professional service engineer to check the appliance.p. 13
F3Fridge compartment sensor faultCall a professional service engineer to check the appliance.p. 13
F4Freezer compartment sensor faultCall a professional service engineer to check the appliance.p. 13
F5Defrosting sensor faultCall a professional service engineer to check the appliance.p. 13
All Verona error codes →

Verona VEFBF2411RISL compared with other brands

Fridge Freezers from other brands with the most of the same figures in their manuals. Values as printed in each manual.

Verona VEFBF2411RISLMidea MRF27I4BSTWhirlpool W10750538AHaier HRQ16N3BGS
Fridge factory setting41 °F (5 °C)37 °F (03 °C)37 °F (3 °C)37 °F (3 °C)
Fridge adjustment range35 °F (2℃) to 46 °F ( 8℃) (2 °C, 8 °C)01 to 07 °C/34 to 44 °F33 °F to 45 °F (0 °C to 7 °C)34 °F to 42 °F (1 °C to 6 °C)
Freezer adjustment range5 °F(-15)℃ to-15 °F(-25℃) (-15 °C, -26 °C)-22 to -14 °C/-07 to 07 °F-5 °F to 5 °F (-21 °C to -15 °C)-6 °F to 4 °F (-21 °C to -16 °C)
Door-open alarm after60 secondsmore than 2 minutes5 minutesmore than 3 minutes
Clearance aboveat least 100mm>1"(25mm) (2.5 cm)¹⁄₂" (1.25 cm)1” (25 mm) (1 in)

Similar bottom freezer models from other brands

Same layout, capacity within 1.5 ft³ (42 L) of this one. Figures: ENERGY STAR.

ModelCapacityEnergy useIceCounter depth
Midea MRB12B111.5 ft³326 L395 kWh/yrNoneNo
Frigidaire FRBG1224AV11.5 ft³326 L397 kWh/yrNoneYes
Insignia NS-RBM11**211.5 ft³326 L395 kWh/yrNoneNo
Sharp SJB1255GS11.5 ft³326 L397 kWh/yrNoneNo
Vesta VRF-NUNAVUT-24SS11.5 ft³326 L397 kWh/yrNoneNo
Aviva ARBM115SB11.5 ft³326 L395 kWh/yrNoneNo

Similar Verona fridge freezers

Verona VEFBF3017RISLBottom Freezer, 18 ft³User Manual29 pages
Verona VEFBF2814RSLBottom Freezer, 14.6 ft³User Manual28 pages
Verona VEFFD3620RISLBottom Freezer, 20.3 ft³Service Manual42 pages
Verona VEBFD3620WIFSBottom Freezer, 20.2 ft³Owner's Manual25 pages
Verona VEFFD3316RISLBottom Freezer, 16.5 ft³User Manual28 pages
Verona VEFFD3018RISLBottom Freezer, 17.5 ft³User Manual28 pages
Verona VEFTF3021RSLModel family VEFUser Manual31 pages
Verona VEFTF3018RBKModel family VEFUser Manual28 pages
All Verona fridge freezers →