Key numbers from this manual

As printed in the manual, with metric and US units side by side. The typical range comes from all refrigerator manuals on this site that print the same figure.

Water filter replacementevery 3-6 monthsdepending on the unit’s exposure level to odorevery three monthswhen the unit is placed in a kitchenTypical for refrigerators: 6 monthsp. 18
Replacement filterZ0F-C004carbon filter replacementp. 18
Clearance behind1” needs less space than mostFor electrical plug clearance at the backTypical for refrigerators: 1.5 to 3 in (3.8 to 7.6 cm)p. 17
Space to open the doors2-1/4”Installation next to a wall, to accommodate the Zephyr handlep. 17
Defrostauto-defrostUnder certain conditions, manual defrosting may be requiredautomatic defrost systemcoolerp. 31 p. 27
Power outagea few hoursduring a power failurep. 29
Sabbath modeYescoolerp. 26
Control lockYescoolerp. 27

Models in this manual

2 models with ENERGY STAR certified data. Models with the same figures share a row.

ModelsTypeCapacityEnergy useIceHeight × width
PRW24F02CGCooler14.5 ft³411 L241 kWh/yr11% below US standard3% more than the median of 18 similar certified models (235 kWh/yr)None69.6 × 23.8 in177 × 60 cm
PRW24F01CGCooler14.9 ft³422 L245 kWh/yr10% below US standard4% more than the median of 15 similar certified models (235 kWh/yr)None69.6 × 23.8 in177 × 60 cm

Zephyr JUN24.0201 questions

Answers taken from this manual. Each one links to the page it comes from.

What space must I leave around the cooler during installation?

Allow the following minimum clearances and cabinet dimensions for installation.

RequirementMinimum spaceApplies to
Back clearance1”Electrical plug
Door clearance2-1/4”Next to a wall
Cabinet width24”Cooler
Cabinet height69-3/4”Cooler

Manual: page 17

How much space does the door need beside a wall?

At least 2-1/4” of clearance is needed beside a wall for the Zephyr handle.

Manual: page 17

How do I clear frost that prevents the cooler door from closing?
  1. Turn the unit off until frost melts, possibly up to 24 hours.
  2. Dry the unit with a soft absorbent towel.
  3. Never use a sharp object to remove frost.

Manual: page 27

Why won't the cooler operate after a power interruption?
  • Power is unavailable. Check that the cooler is plugged in and the outlet has power.
  • The appliance is turned off. Turn on the appliance.
  • A fuse or breaker failed. Replace the fuse or reset the breaker.
  • Sabbath mode may be enabled. Verify that Sabbath mode is disabled.

Manual: page 30

How long can a power failure last before I protect the contents?

A few hours usually will not affect the temperature if you minimize door openings. For a longer outage, protect the contents.

Manual: page 29

Zephyr JUN24.0201 compared with other brands

Refrigerators from other brands with the most of the same figures in their manuals. Values as printed in each manual.

Zephyr JUN24.0201Whirlpool RefrigeratorKitchenAid RefrigeratorMaytag Refrigerator
Water filter replacementevery 3-6 monthsat least every 6 monthsat least every 6 monthsevery 6 months
Replacement filterZ0F-C004W10295370A (P4RFWB)UKF8001AXX-750 or UKF8001AXX-200T2RFWG2, part #4396841
Clearance behind1”2" (5.08 cm)1" (2.54 cm)1" (2.54 cm)
Space to open the doors2-1/4”165°2³⁄₄" (7.0 cm) minimum2" (5.08 cm)

Similar cooler models from other brands

Same layout, capacity within 1.5 ft³ (42 L) of this one. Figures: ENERGY STAR.

ModelCapacityEnergy useIceCounter depth
XO XOU2470WGS14.4 ft³408 L238 kWh/yrNoneNo
Signature Kitchen Suite SKSCW24113.6 ft³385 L175 kWh/yrNoneNo
Monogram ZIW241NBW13.4 ft³379 L118 kWh/yrNoneNo
Fisher & Paykel RS2484V*2K113.3 ft³377 L118 kWh/yrNoneNo