Key numbers from this manual

As printed in the manual, with metric and US units side by side. The typical range comes from all ice maker manuals on this site that print the same figure.

Water supply pressure10 to 70 psi (69 to 483 kPa)water supplyp. 7
Door-open alarm aftermore than 30 minutesp. 12
Clearance aboveno additional air spacebuilt-in installationTypical for ice makers: 0.3 to 6 in (0.8 to 15.2 cm)p. 7
Clearance at the sidesno additional air spacebuilt-in installationTypical for ice makers: 1 to 6 in (2.5 to 15.2 cm)p. 7
Clearance behind2.00" (5.08 cm) needs less space than mostservice clearance behindat least 3" (7.6 cm)behind dispenser for electrical connection and drainTypical for ice makers: 3 to 6 in (7.6 to 15.2 cm)p. 6 p. 7
Space to open the doors2.25" (57 mm)hinge side from wall for 90° door openingzero clearanceadjacent to cabinetsp. 8
Sabbath modeYesunit control operationp. 12

Follett UCD100A30-CF questions

Answers taken from this manual. Each one links to the page it comes from.

How do I replace the water filter?

Rotate the water filter approximately 1/4 turn counterclockwise to remove it, then install a new water filter.

Manual: page 14

Why is condensation forming on the outside of the ice maker?

Excessive humidity causes external condensation; moisture will dissipate as humidity decreases.

Manual: page 15

Why is there water in the ice bin?

A restricted drain can cause water in the ice bin. Clear foreign debris from the drain.

Manual: page 15

How do I start the ice machine cleaning cycle?
  1. Press and hold the clean button for 5 to 10 seconds.
  2. Confirm 01 appears in the display.

Manual: page 13

When should I clean the ice machine?

Approximately every six months under normal use, when CL appears. Clean more often if water conditions require it, or if ice quality or output declines.

Manual: page 13

What clearances does this ice maker need for installation?

Built-in installation has specific grille, rear, and cabinet-door requirements.

  • Top, sides, and rear need no additional air space, but the front grille must remain unobstructed.
  • Allow at least 3" (7.6 cm) behind the dispenser for the electrical connection and drain.
  • The drawing lists 2.00" (5.08 cm) behind as service clearance.
  • Do not install the unit behind a closed cabinet door.

Other brands: Scotsman 0 clearance · GE 3 in · Other 5 inches (12.7 cm) Compare all

Manual: page 6, page 7

How much hinge-side space is needed for the door to open 90°?
  • Allow 2.25" (57 mm) from the wall on the hinge side.
  • Adjacent cabinets can have zero clearance.

Manual: page 8

How do I fix an ice maker door that is not sealing?

Adjust the hinges until the gasket contacts the cabinet completely without gaps.

  1. Remove the top hinge cover carefully.
  2. Loosen the upper and lower hinge screws without removing them.
  3. Square the door with the cabinet.
  4. Check that the gasket touches the cabinet around the entire door, with no gaps.
  5. Tighten the lower hinge screws, then the upper screws.
  6. Replace the hinge cover.

Manual: page 10

How do I reinstall the door gasket after reversing the door?

Reposition the gasket before putting the reversed door back on its hinges.

  1. Remove the gasket from the door.
  2. Turn the gasket 180°.
  3. Press it firmly into the channel, beginning at the corners.
  4. Rotate the door 180° for the reversed position.
  5. Place the door onto the bottom hinge.
  6. Align the hinge with the unit’s outside edge and tighten its three screws.

Manual: page 10

What do the error codes on my ice maker mean?

The display shows these codes and conditions; only the door error has an audible signal.

CodeMeaning or response
E1, E5Thermistor 1 open or shorted
E2 to E4, E6 to E8Thermistors not used
E9, E10Door 1 open, Door 2 not used
E11, E12Water level high or low
E13 to E15Auger, undercurrent, or overcurrent
P1Drain pump error

Manual: page 35, page 36

Why is the alert light flashing?

View errors in service mode, then correct the condition identified by the logged error.

Manual: page 34

Error codes in this manual

CodeMeaningWhat to do
E1Thermistor 1 is open.Measure resistance and compare with the service manual chart; replace if open circuit.p. 35
E2Thermistor 2 is open; unused.p. 35
E3Thermistor 3 is open; unused.p. 35
E4Thermistor 4 is open; unused.p. 35
E5Thermistor 1 is shorted.Measure resistance and compare with the service manual chart; replace if shorted.p. 35
E6Thermistor 2 is shorted; unused.p. 35
E7Thermistor 3 is shorted; unused.p. 35
E8Thermistor 4 is shorted; unused.p. 35
E9Door 1 has been open too long.Check the plunger switch; reset after closing the door if needed.p. 35
E10Door 2 is open; unused.p. 35
E11Water level is high in the tray or chassis.Tilt the unit back to drain it, inspect for leaks, and correct the cause; then power reset.p. 35
E12Water level is low.Check the water valve, hose, and reservoir float switch; press Clean to reset.p. 35
E13Auger has an error.Clean the unit; check the reservoir float switch, condenser fan, and control board.p. 36
E14Auger current is too low.Service notice is generated in the app.p. 36
E15Auger current is too high.Service notice is generated in the app.p. 36
P1Drain pump has an error.Check and clean hoses and connections; replace the drain pump if defective.p. 36
All Follett error codes →

Follett UCD100A30-CF compared with other brands

Ice Makers from other brands with the most of the same figures in their manuals. Values as printed in each manual.

Follett UCD100A30-CFOther HZB-45ANewAir NCI066SSN0Koolmore CIM198
Water supply pressure10 to 70 psi (69 to 483 kPa)15 to 116 psi (100 to 800 kPa)6 to 87 psi (40 to 600 kPa)15 to 116 psi (100 to 800 kPa)
Door-open alarm aftermore than 30 minutes···
Clearance behind2.00" (5.08 cm)5CM2 inches (5.1 cm)5CM
Space to open the doors2.25" (57 mm)25 CM10 inches (25.4 cm)25 CM

Similar Follett ice makers

Follett UFD414A80Installation & Operation Manual48 pages
Follett 15CI114A-NW-**-**-**Installation & Operation Manual71 pages
Follett 25CI414A-LIInstallation & Operation Manual64 pages
Follett 12CI414AInstallation & Operation Manual60 pages
Follett D1810R-**Service Manual54 pages
Follett C1414AService Manual54 pages
Follett HCF1810RService Manual54 pages
Follett HCF1810RService Manual52 pages
All Follett ice makers →