Have a question about the Follett UCD100A30-CF? The AI assistant looks through this manual and shows the pages with the answer.
Key numbers from this manual
As printed in the manual, with metric and US units side by side. The typical range comes from all ice maker manuals on this site that print the same figure.
| Water supply pressure | 10 to 70 psi (69 to 483 kPa)water supply | p. 7 |
|---|---|---|
| Door-open alarm after | more than 30 minutes | p. 12 |
| Clearance above | no additional air spacebuilt-in installationTypical for ice makers: 0.3 to 6 in (0.8 to 15.2 cm) | p. 7 |
| Clearance at the sides | no additional air spacebuilt-in installationTypical for ice makers: 1 to 6 in (2.5 to 15.2 cm) | p. 7 |
| Clearance behind | 2.00" (5.08 cm) needs less space than mostservice clearance behindat least 3" (7.6 cm)behind dispenser for electrical connection and drainTypical for ice makers: 3 to 6 in (7.6 to 15.2 cm) | p. 6 p. 7 |
| Space to open the doors | 2.25" (57 mm)hinge side from wall for 90° door openingzero clearanceadjacent to cabinets | p. 8 |
| Sabbath mode | Yesunit control operation | p. 12 |
Follett UCD100A30-CF questions
Answers taken from this manual. Each one links to the page it comes from.
How do I replace the water filter?
Rotate the water filter approximately 1/4 turn counterclockwise to remove it, then install a new water filter.
Manual: page 14
Why is condensation forming on the outside of the ice maker?
Excessive humidity causes external condensation; moisture will dissipate as humidity decreases.
Manual: page 15
Why is there water in the ice bin?
A restricted drain can cause water in the ice bin. Clear foreign debris from the drain.
Manual: page 15
How do I start the ice machine cleaning cycle?
- Press and hold the clean button for 5 to 10 seconds.
- Confirm 01 appears in the display.
Manual: page 13
When should I clean the ice machine?
Approximately every six months under normal use, when CL appears. Clean more often if water conditions require it, or if ice quality or output declines.
Manual: page 13
What clearances does this ice maker need for installation?
Built-in installation has specific grille, rear, and cabinet-door requirements.
- Top, sides, and rear need no additional air space, but the front grille must remain unobstructed.
- Allow at least 3" (7.6 cm) behind the dispenser for the electrical connection and drain.
- The drawing lists 2.00" (5.08 cm) behind as service clearance.
- Do not install the unit behind a closed cabinet door.
Other brands: Scotsman 0 clearance · GE 3 in · Other 5 inches (12.7 cm) Compare all
How much hinge-side space is needed for the door to open 90°?
- Allow 2.25" (57 mm) from the wall on the hinge side.
- Adjacent cabinets can have zero clearance.
Manual: page 8
How do I fix an ice maker door that is not sealing?
Adjust the hinges until the gasket contacts the cabinet completely without gaps.
- Remove the top hinge cover carefully.
- Loosen the upper and lower hinge screws without removing them.
- Square the door with the cabinet.
- Check that the gasket touches the cabinet around the entire door, with no gaps.
- Tighten the lower hinge screws, then the upper screws.
- Replace the hinge cover.
Manual: page 10
How do I reinstall the door gasket after reversing the door?
Reposition the gasket before putting the reversed door back on its hinges.
- Remove the gasket from the door.
- Turn the gasket 180°.
- Press it firmly into the channel, beginning at the corners.
- Rotate the door 180° for the reversed position.
- Place the door onto the bottom hinge.
- Align the hinge with the unit’s outside edge and tighten its three screws.
Manual: page 10
What do the error codes on my ice maker mean?
The display shows these codes and conditions; only the door error has an audible signal.
| Code | Meaning or response |
|---|---|
| E1, E5 | Thermistor 1 open or shorted |
| E2 to E4, E6 to E8 | Thermistors not used |
| E9, E10 | Door 1 open, Door 2 not used |
| E11, E12 | Water level high or low |
| E13 to E15 | Auger, undercurrent, or overcurrent |
| P1 | Drain pump error |
Why is the alert light flashing?
View errors in service mode, then correct the condition identified by the logged error.
Manual: page 34
Error codes in this manual
| Code | Meaning | What to do | |
|---|---|---|---|
| E1 | Thermistor 1 is open. | Measure resistance and compare with the service manual chart; replace if open circuit. | p. 35 |
| E2 | Thermistor 2 is open; unused. | p. 35 | |
| E3 | Thermistor 3 is open; unused. | p. 35 | |
| E4 | Thermistor 4 is open; unused. | p. 35 | |
| E5 | Thermistor 1 is shorted. | Measure resistance and compare with the service manual chart; replace if shorted. | p. 35 |
| E6 | Thermistor 2 is shorted; unused. | p. 35 | |
| E7 | Thermistor 3 is shorted; unused. | p. 35 | |
| E8 | Thermistor 4 is shorted; unused. | p. 35 | |
| E9 | Door 1 has been open too long. | Check the plunger switch; reset after closing the door if needed. | p. 35 |
| E10 | Door 2 is open; unused. | p. 35 | |
| E11 | Water level is high in the tray or chassis. | Tilt the unit back to drain it, inspect for leaks, and correct the cause; then power reset. | p. 35 |
| E12 | Water level is low. | Check the water valve, hose, and reservoir float switch; press Clean to reset. | p. 35 |
| E13 | Auger has an error. | Clean the unit; check the reservoir float switch, condenser fan, and control board. | p. 36 |
| E14 | Auger current is too low. | Service notice is generated in the app. | p. 36 |
| E15 | Auger current is too high. | Service notice is generated in the app. | p. 36 |
| P1 | Drain pump has an error. | Check and clean hoses and connections; replace the drain pump if defective. | p. 36 |
Follett UCD100A30-CF compared with other brands
Ice Makers from other brands with the most of the same figures in their manuals. Values as printed in each manual.
| Follett UCD100A30-CF | Other HZB-45A | NewAir NCI066SSN0 | Koolmore CIM198 | |
|---|---|---|---|---|
| Water supply pressure | 10 to 70 psi (69 to 483 kPa) | 15 to 116 psi (100 to 800 kPa) | 6 to 87 psi (40 to 600 kPa) | 15 to 116 psi (100 to 800 kPa) |
| Door-open alarm after | more than 30 minutes | · | · | · |
| Clearance behind | 2.00" (5.08 cm) | 5CM | 2 inches (5.1 cm) | 5CM |
| Space to open the doors | 2.25" (57 mm) | 25 CM | 10 inches (25.4 cm) | 25 CM |
Similar Follett ice makers
| Follett UFD414A80 | Installation & Operation Manual | 48 pages |
|---|---|---|
| Follett 15CI114A-NW-**-**-** | Installation & Operation Manual | 71 pages |
| Follett 25CI414A-LI | Installation & Operation Manual | 64 pages |
| Follett 12CI414A | Installation & Operation Manual | 60 pages |
| Follett D1810R-** | Service Manual | 54 pages |
| Follett C1414A | Service Manual | 54 pages |
| Follett HCF1810R | Service Manual | 54 pages |
| Follett HCF1810R | Service Manual | 52 pages |