Follett error codes
29 Follett error and alarm codes from 3 manuals: what each code means and what the manual says to do.
29 codes3 manuals
Codes and what they mean
As described in each manual. The same code can mean different things on different models, so check the model column.
| Code | Meaning | What to do | Manual |
|---|---|---|---|
| BPr | Probe error detected. | 01441492R00 | |
| E1 | Thermistor 1 is open. | Measure resistance and compare with the service manual chart; replace if open circuit. | UCD100A30-CF |
| E2 | Thermistor 2 is open; unused. | UCD100A30-CF | |
| E3 | Thermistor 3 is open; unused. | UCD100A30-CF | |
| E4 | Thermistor 4 is open; unused. | UCD100A30-CF | |
| E5 | Thermistor 1 is shorted. | Measure resistance and compare with the service manual chart; replace if shorted. | UCD100A30-CF |
| E6 | Thermistor 2 is shorted; unused. | UCD100A30-CF | |
| E7 | Thermistor 3 is shorted; unused. | UCD100A30-CF | |
| E8 | Thermistor 4 is shorted; unused. | UCD100A30-CF | |
| E9 | Door 1 has been open too long. | Check the plunger switch; reset after closing the door if needed. | UCD100A30-CF |
| E10 | Door 2 is open; unused. | UCD100A30-CF | |
| E11 | Water level is high in the tray or chassis. | Tilt the unit back to drain it, inspect for leaks, and correct the cause; then power reset. | UCD100A30-CF |
| E12 | Water level is low. | Check the water valve, hose, and reservoir float switch; press Clean to reset. | UCD100A30-CF |
| E13 | Auger has an error. | Clean the unit; check the reservoir float switch, condenser fan, and control board. | UCD100A30-CF |
| E14 | Auger current is too low. | Service notice is generated in the app. | UCD100A30-CF |
| E15 | Auger current is too high. | Service notice is generated in the app. | UCD100A30-CF |
| Er01 | Evaporator temperature remains at least 36 °F after 30 minutes of ice making. | IU-0345-AN | |
| Er03 | Evaporator temperature remains at least 32 °F after 10 minutes of ice making. | IU-0345-AN | |
| Er05 | Ice full sensor is disconnected or shorted. | IU-0345-AN | |
| Er06 | Evaporator temperature sensor is disconnected or shorted. | IU-0345-AN | |
| Er07 | Air temperature sensor is disconnected or shorted. | IU-0345-AN | |
| Er08 | Condenser temperature sensor is disconnected or shorted. | IU-0345-AN | |
| Er13 | Condenser temperature reaches at least 149 °F for over 10 seconds. | IU-0345-AN | |
| Er14 | Er13 occurs three times within one hour. | Check condenser blockage, ventilation, fan operation, and room temperature. | IU-0345-AN |
| Er15 | Water level is undetected because no water supplied for two minutes. | Check water pressure and level sensor, then restart operation. | IU-0345-AN |
| Er16 | Lower water level sensor is undetected within two minutes of draining. | Replace sensor; check drain valve and blockage, then restart operation. | IU-0345-AN |
| Er21 | Evaporator temperature drops below -4 °F during ice making. | Check refrigerant levels and sensors; replace faulty components if necessary. | IU-0345-AN |
| Er22 | Auger motor stops during ice making. | Check for evaporator freezing and inspect the auger motor wiring. | IU-0345-AN |
| P1 | Drain pump has an error. | Check and clean hoses and connections; replace the drain pump if defective. | UCD100A30-CF |