Key numbers from this manual
As printed in the manual, with metric and US units side by side. The typical range comes from all fridge freezer manuals on this site that print the same figure.
| Time to cool down | 4 hoursAfter the freezer has been disconnected, before adding foodTypical for fridge freezers: 4 to 24 hours | p. 17 |
|---|---|---|
| Door-open alarm after | 5 minutes later than mostFreezer doorTypical for fridge freezers: 1.4 to 3 minutes | p. 14 |
| Clearance above | 3" (7.6 cm)At the top of the freezerTypical for fridge freezers: 1 to 3.9 in (2.5 to 9.9 cm) | p. 6 |
| Clearance at the sides | 3" (7.6 cm)At both sides of the freezerTypical for fridge freezers: 0.5 to 3.9 in (1.3 to 9.9 cm) | p. 6 |
| Space to open the doors | sufficient spaceOn the hinge side next to a fixed wall | p. 6 |
Models in this manual
2 models with ENERGY STAR certified data. Models with the same figures share a row.
| Models | Type | Capacity | Energy use | Ice | Height × width |
|---|---|---|---|---|---|
| MRU17F6A, MRU17F6AWW | Upright Freezer | 17 ft³481 L | 438 kWh/yr10% below US standardabout the same as the median of 105 similar certified models (438 kWh/yr) | None |
Midea MRU17F6AWW questions
Answers taken from this manual. Each one links to the page it comes from.
Why is my freezer not cold?
- Door opened often or not sealed. Check the gasket and food placement, then close the door fully.
- Temperature control set too warm. Set the control to a colder setting.
- Cabinet touching a wall. Move the freezer away from the wall.
- Hot, humid weather. This condition is normal.
Manual: page 17
How long should I wait after reconnecting the freezer before adding food?
4 hours. Let the freezer cool completely before adding food.
Manual: page 17
Why does the freezer not operate?
- The freezer is unplugged. Fully plug the power cord into the electrical outlet.
- A fuse is blown or the circuit breaker is tripped. Replace the fuse or reset the breaker.
- A power failure occurred. Wait until power is restored.
Manual: page 16
Why is the high-temperature alert sounding?
The alert means the interior exceeds 18 °F (-8 °C) in FREEZER MODE, or 59 °F (15 °C) in FRIDGE MODE, for 36 hours. Press any control-panel button to silence it; the alert turns off automatically when temperatures return to normal.
Manual: page 14
What should I check when the freezer door does not close completely?
- Food is blocking the door. Rearrange or remove items.
- The door gaskets are dirty. Clean the gaskets.
- The freezer is not level. Level the freezer.
Manual: page 16
Why does the Door open alert appear?
The door is open. Close it, then check that items do not block it and that the freezer is level.
Manual: page 18
What do the freezer error codes mean?
The code identifies the fault, and each listed fault requires service.
| Code | Meaning | Action |
|---|---|---|
| E2 | Temperature sensor fault | Call for service. |
| E5 | Defrost sensor fault | Call for service. |
| E7 | Ambient temperature sensor fault | Call for service. |
Manual: page 19
Error codes in this manual
| Code | Meaning | What to do | |
|---|---|---|---|
| E2 | Temperature sensor failure. | Call for service. | p. 19 |
| E5 | Defrost sensor failure. | Call for service. | p. 19 |
| E7 | Ambient temperature sensor failure. | Call for service. | p. 19 |
Midea MRU17F6AWW compared with other brands
Fridge Freezers from other brands with the most of the same figures in their manuals. Values as printed in each manual.
| Midea MRU17F6AWW | Whirlpool W10750538A | GE Fridge Freezer | Frigidaire FRFG1723AV | |
|---|---|---|---|---|
| Time to cool down | 4 hours | 24 hours | 24 hours | within 24 hours |
| Door-open alarm after | 5 minutes | 5 minutes | 2 minutes | 5 minutes |
| Clearance above | 3" (7.6 cm) | ¹⁄₂" (1.25 cm) | 1" (25 mm) | ⅜ inch (9.5 mm) |
| Clearance at the sides | 3" (7.6 cm) | ¹⁄₂" (1.25 cm) | 1/8" (3 mm) | ⅜ inch (9.5 mm) |
Similar upright freezer models from other brands
Same layout, capacity within 1.5 ft³ (42 L) of this one. Figures: ENERGY STAR.
| Model | Capacity | Energy use | Ice | Counter depth |
|---|---|---|---|---|
| Avanti AV170VFLJM | 17 ft³481 L | 438 kWh/yr | None | No |
| Criterion CUF17P1W | 17 ft³481 L | 435 kWh/yr | None | No |
| Element EXUF17CEES | 17 ft³481 L | 435 kWh/yr | None | No |
| GE FUF17DL | 17.3 ft³490 L | 441 kWh/yr | None | No |
| Monogram ZIF301NBR | 16.7 ft³473 L | 579 kWh/yr | Ice maker, door dispenser | No |
| Dacor DRZ30980 | 17.6 ft³498 L | 550 kWh/yr | Ice maker, door dispenser | No |
Similar Midea fridge freezers
| Midea WHS-625FWESS1Upright Freezer, 17 ft³ | User Manual | 19 pages |
|---|---|---|
| Midea MU138SWAR1RC1Upright Freezer, 13.8 ft³ | User Manual | 48 pages |
| Midea MRU21C7BSTUpright Freezer, 20 ft³ | User Manual | 24 pages |
| Midea MRU14B2ASLUpright Freezer, 13.8 ft³ | User Manual | 64 pages |
| Midea MRU14F5ASTUpright Freezer, 13.8 ft³ | User Manual | 1 pages |
| Midea 16131000A51956Upright Freezer, 20 ft³ | Instruction Manual | 73 pages |
| Midea MRU14B3AWWModel family MRU1 | User Manual | 56 pages |
| Midea MRQ22D7AST | User Manual | 148 pages |