Have a question about the U-Line UONP115-SS01A? The AI assistant looks through this manual and shows the pages with the answer.
Key numbers from this manual
As printed in the manual, with metric and US units side by side. The typical range comes from all ice maker manuals on this site that print the same figure.
| Water filter replacement | when you clean your machineSelect models with a water filterTypical for ice makers: 6 months | p. 25 |
|---|---|---|
| Replacement filter | ULANUGGETFILTERSelect models with an internal water filter | p. 25 |
| Door-open alarm after | 5 minutesdoor left open | p. 45 |
| Clearance above | does not require additional air spacebuilt-in installationTypical for ice makers: 0.3 to 6 in (0.8 to 15.2 cm) | p. 8 |
| Clearance at the sides | does not require additional air spacebuilt-in installationTypical for ice makers: 1 to 6 in (2.5 to 15.2 cm) | p. 8 |
| Clearance behind | does not require additional air spacebuilt-in installation, except clearance for an electrical connectionTypical for ice makers: 3 to 6 in (7.6 to 15.2 cm) | p. 8 |
| Space to open the doors | 1/4" (6 mm)side-by-side installation, between the units | p. 9 |
U-Line UONP115-SS01A questions
Answers taken from this manual. Each one links to the page it comes from.
The display shows E11 and water is near the base. What should I do?
Water detected by the base sensor triggers E11; dry the probes, then cycle power.
- Inspect the entire base area in front of and behind the sensors for water.
- Completely dry the two probes.
- Cycle power using the rocker switch or power cord.
- Check the connection from the bin to the drain.
- Allow 20 minutes before the error can reactivate.
Manual: page 46
Why did the compressor stop running after repeated relay cycling?
Frequent compressor relay toggling can trigger overload, which deactivates it until the overload switch cools; leave at least 5 minutes between relay cycles.
Manual: page 45
What does E11 mean when the ice maker stops?
E11 means the base sensor detected water. Dry the two probes completely, cycle power with the rocker switch or power cord, and allow 20 minutes before the error can reactivate.
Manual: page 46
What cleaning interval matches my water’s TDS level?
Measure the water supply’s TDS before choosing the cleaning interval.
| Water TDS | Cleaning interval |
|---|---|
| 5 to 150 ppm | 6 months |
| 150 to 200 ppm | 4 months |
Manual: page 24
How often should I clean this ice machine?
The display shows CL when cleaning is due, but water TDS determines the interval.
| Water TDS | Cleaning interval |
|---|---|
| 5 to 150 ppm | 6 months |
| 150 to 200 ppm | 4 months |
Manual: page 24
How much space belongs between side-by-side units?
1/4" (6 mm) of space must be maintained between side-by-side units for unobstructed door swing.
Manual: page 9
What clearance does built-in installation require?
Built-in installation needs no extra space above, beside, or behind the unit. Keep the front grille clear. Leave rear space for the electrical connection. Do not install the unit behind a closed cabinet door.
Manual: page 8
Error codes in this manual
| Code | Meaning | What to do | |
|---|---|---|---|
| E1 | Thermistor 1 is open. | p. 29 | |
| E2 | Thermistor 2 is open. | p. 29 | |
| E3 | Thermistor 3 is open. | p. 29 | |
| E4 | Thermistor 4 is open. | p. 29 | |
| E5 | Thermistor 1 is shorted. | p. 29 | |
| E6 | Thermistor 2 is shorted. | p. 29 | |
| E7 | Thermistor 3 is shorted. | p. 29 | |
| E8 | Thermistor 4 is shorted. | p. 29 | |
| E9 | Door 1 is open. | p. 29 | |
| E10 | Door 2 is open; displayed as 10. | p. 29 | |
| E11 | Water level in the tray or reservoir is high. | Dry both probes, then cycle power; inspect sensors, pan, and wiring. | p. 29 |
| E12 | Water level is low; the reservoir is not filling sufficiently. | Check water supply, filter, valves, pump, and connections; power cycle after corrections. | p. 29 |
| E13 | Auger error. | p. 29 | |
| P1 | Pump circuit is open. | p. 29 |
U-Line UONP115-SS01A compared with other brands
Ice Makers from other brands with the most of the same figures in their manuals. Values as printed in each manual.
| U-Line UONP115-SS01A | Follett UCD100A30-CF | |
|---|---|---|
| Door-open alarm after | 5 minutes | more than 30 minutes |
| Space to open the doors | 1/4" (6 mm) | 2.25" (57 mm) |
Similar U-Line ice makers
| U-Line UONP115-SS01CModel family UONP115SS01 | User Manual | 32 pages |
|---|