Key numbers from this manual
As printed in the manual, with metric and US units side by side. The typical range comes from all walk-in cooler manuals on this site that print the same figure.
| Freezer adjustment range | -18 °C (0 °F) to -22 °C (-8 °F)Freezer Storage mode on combination blast chiller freezers | p. 8 |
|---|---|---|
| Time to cool down | half an hourBefore using the cabinet | p. 8 |
| Clearance above | 500mmWBC/WBCF50 cabinets with top-mounted systems, between cabinet top and ceiling | p. 5 |
| Defrost | automaticAt the end of each blast chill cycle and during storage mode | p. 9 |
Williams WBCF10 questions
Answers taken from this manual. Each one links to the page it comes from.
What temperatures do the blast chiller and freezer modes use?
The settings are listed below, with storage temperature depending on the selected cycle.
| Mode | Temperature |
|---|---|
| Blast Chill Soft | +1 °C (34 °F) |
| Blast Chill Hard | -10 °C (14 °F) |
| Default Storage | +1 °C (34 °F) to +3 °C (37 °F) |
| Freezer Storage | -18 °C (0 °F) to -22 °C (-8 °F) |
| Blast Freeze | -25 °C (-13 °F) |
Other brands: LG from -24 °C to -16 °C (-11 °F, 3 °F) · Samsung -15 °C and -23 °C (5 °F, -9 °F) · Midea -12 to -24 °C (10 to -11 °F) Compare all
Manual: page 8
How long should the cabinet run before I use it?
Half an hour, before using the cabinet.
Manual: page 8
What clearance does my Williams blast chiller need around it?
The required clearance depends on the cabinet and its top-mounted system.
- WBC/WBCF50: Leave 500mm between the cabinet top and ceiling for access and ventilation.
- All other cabinets: Provide at least 50mm around the unit for proper performance.
Other brands: LG 12 Inches (30 cm) (11.8 in) · Samsung at least 50 mm (2 in) · Midea 11.8 inches (30 cm) Compare all
Manual: page 5
How do I clean the door gasket?
- Wipe the gasket with warm soapy water and a soft cloth.
- Dry the gasket completely before closing the door.
- Do not scrape or clean it with a sharp knife.
Manual: page 13
How do I replace a damaged door gasket?
- Pull the damaged gasket out of its channel.
- Press the replacement gasket into the channel at the center.
- Continue pressing the gasket into the channel around the door.
Manual: page 13
What does E3 mean after the appliance loses power?
A mains failure longer than 3 minutes triggers E3; the alarm retriggers until the fault is addressed.
Manual: page 10
How do I reset the flashing red condenser-clean LED?
Hold the condenser clean button for 3 seconds to reset its timer and stop the LED flashing.
Manual: page 11
What do the alarm codes mean?
The controller uses these displays to identify alarm conditions and temperature faults.
| Display | Meaning |
|---|---|
| AL 03 | General alarm |
| --- dF | Mains failure over 3 minutes |
| E1 | HP/LP fault, not applicable |
| E2 | Over temperature |
| E3 | Mains failure over 3 minutes |
| Hi, Lo, or or | High, low, or probe-range fault |
Manual: page 10
What do the probe displays T1 through T6 identify?
The left display identifies the probe, while the right display shows its fault type.
| Display | Probe |
|---|---|
| T1 | Air probe |
| T2 | Evaporator probe |
| T3 | Auxiliary probe, not applicable |
| T4 | Food Probe 1 |
| T5 | Food Probe 2 |
| T6 | Food Probe 3 |
Manual: page 10
Error codes in this manual
| Code | Meaning | What to do | |
|---|---|---|---|
| AL 03 | General alarm; display also shows operating mode. | Mute the alarm and address the fault causing it. | p. 10 |
| dF | Mains failure lasting longer than three minutes. | Mute the alarm and address the fault causing it. | p. 10 |
| E1 | High or low pressure fault; not applicable. | Mute the alarm and address the fault causing it. | p. 10 |
| E2 | Overtemperature condition. | Mute the alarm and address the fault causing it. | p. 10 |
| E3 | Mains failure lasting longer than three minutes. | Mute the alarm and address the fault causing it. | p. 10 |
| Hi | High temperature. | Mute the alarm and address the fault causing it. | p. 10 |
| Lo | Low temperature. | Mute the alarm and address the fault causing it. | p. 10 |
| or | Probe measurement is outside its range. | Mute the alarm and address the fault causing it. | p. 10 |
| T1 | Air probe | p. 10 | |
| T2 | Evaporator probe | p. 10 | |
| T3 | Auxiliary probe, not applicable | p. 10 | |
| T4 | Food Probe 1 | p. 10 | |
| T5 | Food Probe 2 | p. 10 | |
| T6 | Food Probe 3 | p. 10 |
Similar Williams walk-in coolers & cold rooms
| Williams WBCF10Model family WBCF10 | Operating Instructions | 20 pages |
|---|---|---|
| Williams POD Refrigeration | Service Manual | 4 pages |