Key numbers from this manual
As printed in the manual, with metric and US units side by side. The typical range comes from all walk-in cooler manuals on this site that print the same figure.
| Recommended fridge temperature | +1 °C (34 °F) to +3 °C (37 °F)Normal storage mode for blast chillers | p. 4 |
|---|---|---|
| Fridge adjustment range | +1 °C (34 °F) to +3 °C (37 °F)Normal storage mode | p. 4 |
| Recommended freezer temperature | -18 °C (0 °F) to -22 °C (-8 °F)Freezer storage mode for combination blast chiller freezers | p. 4 |
| Freezer adjustment range | -18 °C (0 °F) to -22 °C (-8 °F)Freezer storage on combination blast chiller freezers | p. 4 |
| Clearance above | 500mmWBC/WBCF50, between cabinet top and ceiling | p. 2 |
| Defrost | automaticAfter blast chill cycles and during storage mode | p. 5 |
Williams WBCF10 questions
Answers taken from this manual. Each one links to the page it comes from.
What clearance does the cabinet need during installation?
The required clearance depends on the cabinet type.
| Cabinet | Required clearance |
|---|---|
| WBC/WBCF50 | 500mm above the cabinet |
| All other cabinets | 50mm/2” around the unit |
Other brands: LG 12 Inches (30 cm) (11.8 in) · Samsung at least 50 mm (2 in) · Midea 11.8 inches (30 cm) Compare all
Manual: page 2
Why does the installation room need ventilation?
Adequate room ventilation is required because refrigeration equipment releases considerable heat; poor ventilation can overheat the motor and increase electricity use.
Manual: page 2
How do I replace a damaged door gasket?
Pull out the damaged gasket and fit the replacement into its channel.
- Pull the existing gasket out.
- Push the new gasket into the channel at the centre.
- Work along the channel, pressing the gasket into place.
- Fit the remaining three sides, pushing the corners in last.
Manual: page 8
How do I clean and check the door gasket?
Clean the gasket regularly and inspect it for damage.
- Wipe the gasket using warm soapy water and a soft cloth.
- Let the gasket dry fully before closing the door.
- Do not clean or scrape the gasket with a sharp knife.
- Replace a damaged gasket, which can raise electricity use and reduce cabinet efficiency and performance.
Manual: page 7
What does E3 mean after a power interruption?
A mains failure lasted longer than 3 minutes; E3 is the displayed alarm code, and the alarm can retrigger until addressed.
Manual: page 5
How do I reset the flashing condenser-clean light?
What do the Williams alarm codes mean?
These displayed codes identify the alarm or probe condition.
| Code | Meaning |
|---|---|
| E1 | HP/LP fault, not applicable |
| E2 | Over temperature |
| E3 | Mains failure longer than 3 minutes |
| Hi | High temperature |
| Lo | Low temperature |
| or | Probe over range failure |
Manual: page 5
Error codes in this manual
| Code | Meaning | What to do | |
|---|---|---|---|
| AL | An alarm condition is present. | Press the mute control; the alarm returns if the fault remains. | p. 5 |
| dF | The appliance is in defrost mode or reports a mains failure. | p. 5 | |
| E1 | High or low pressure fault; not applicable. | p. 5 | |
| E2 | Temperature is too high. | p. 5 | |
| E3 | Mains power failed for more than three minutes. | p. 5 | |
| Hi | High temperature alarm. | p. 5 | |
| Lo | Low temperature alarm. | p. 5 | |
| or | Probe measurement is beyond its operating range. | p. 5 | |
| T1 | Air probe fault or air probe identifier. | p. 5 | |
| T2 | Evaporator probe fault or evaporator probe identifier. | p. 5 | |
| T3 | Auxiliary probe, not applicable. | p. 5 | |
| T4 | Food probe 1 identifier. | p. 5 | |
| T5 | Food probe 2 identifier. | p. 5 | |
| T6 | Food probe 3 identifier. | p. 5 |
Similar Williams walk-in coolers & cold rooms
| Williams WBCF10Model family WBCF10 | Operating Instructions | 20 pages |
|---|---|---|