Have a question about the Daewoo FN-510DW? The AI assistant looks through this manual and shows the pages with the answer.
Key numbers from this manual
As printed in the manual, with metric and US units side by side. The typical range comes from all refrigerator manuals on this site that print the same figure.
| Fridge factory setting | step “3”initial mode by power inputTypical for refrigerators: 37 to 39 °F (3 to 4 °C) | p. 21 |
|---|---|---|
| Fridge adjustment range | “1” → “2” → “3” → “4” → “5”refrigerator compartment temperature settingTypical for refrigerators: 36 to 46 °F (2 to 8 °C) | p. 21 |
Daewoo FN-510DW questions
Answers taken from this manual. Each one links to the page it comes from.
How do I adjust the refrigerator temperature?
- Press UP to cycle from step “1” through step “5”.
- Press DOWN to cycle from step “5” back through step “1”.
- Stop pressing buttons, and the setting saves after 5 sec.
Manual: page 21
How do I control the freezer temperature?
Use KNOB F LOUVER in the freezer to control its temperature.
Manual: page 21
How do I remove the water tank and dispenser panel?
- Press Stopper Water Tank, then pull away Water Tank As.
- Remove the bottom screws from Panel Dispns As, then take the panel apart.
Manual: page 19
How do I exit DEMO mode?
Press TEMP and S-COOL together for 5 seconds, or turn off power and restart.
Manual: page 25
Why doesn't the compressor restart right away?
The delay protects the compressor after it turns off.
| Condition | Restart delay | Exception |
|---|---|---|
| RT sensor ≥ 20 °C | 6 min | None stated |
| RT sensor ≤ 19 °C | 30 min | Doors open more than 20 seconds: 6 min |
Manual: page 24
Why does the refrigerator beep after startup?
After 2 minutes, the buzzer sounds 3 times.
Manual: page 24
How do I check and stop an error display?
- Hold UP, then press DOWN 5 times to check for errors.
- Press SAVE once, or wait 4 minutes, to stop the error display.
- After operation returns to normal, the error display resets.
Manual: page 27
Error codes in this manual
| Code | Meaning | What to do | |
|---|---|---|---|
| C1 | Defrost sensor exceeds minus five degrees Celsius while the compressor runs over three hours. | The system continues normal operation; cancellation occurs when conditions return to normal. | p. 27 |
| D1 | Defrost sensor is open or shorted. | Normal operation resumes when the defrost sensor works normally. | p. 27 |
| DR | Door has remained open for more than one hour. | Open and close the door to terminate the error automatically. | p. 27 |
| F3 | Defrost fault requiring the next limit defrost time. | During defrost, delete pre cooling; cancellation occurs when defrost completes through the defrost sensor. | p. 27 |
| R1 | Refrigerator sensor is open or shorted. | Normal operation resumes when the refrigerator sensor works normally. | p. 27 |
| RT | RT sensor is open or shorted. | Normal operation resumes when the RT sensor works normally. | p. 27 |
Daewoo FN-510DW compared with other brands
Refrigerators from other brands with the most of the same figures in their manuals. Values as printed in each manual.
| Daewoo FN-510DW | LG L708BSL | Samsung RR39A7463AP | Midea MD-RT339WEDMX02 | |
|---|---|---|---|---|
| Fridge factory setting | step “3” | 3 °C (37 °F) | 3 °C (37 °F) | 4℃ |
| Fridge adjustment range | “1” → “2” → “3” → “4” → “5” | from 0 °C to 6 °C (32 °F, 43 °F) | 7 °C and 1 °C (45 °F, 34 °F) | 8℃, 6℃, 4℃, 2℃ |
Similar Daewoo refrigerators
| Daewoo FRN-U20DBModel family FRN | Service Manual | 92 pages |
|---|---|---|
| Daewoo FRSU20IA01Model family FRS | Service Manual | 56 pages |
| Daewoo FR-631NDModel family FR6 | Service Manual | 44 pages |
| Daewoo FR-581NTModel family FR5 | Service Manual | 31 pages |
| Daewoo FRQ501DF01 | Service Manual | 112 pages |
| Daewoo DRX32DDL | User Manual | 18 pages |
| Daewoo 272SVC | Service Manual | 14 pages |
| Daewoo 272SVC | Service Manual | 13 pages |