| 33 | Temperature display indicates sensor disconnection or short circuit. | Refrigerator | |
| 33 | Temperature display shows sensor disconnection or short circuit. | FRQ501DF01 | |
| C1 | Freezer compressor fails to run for 60 minutes after switching off. | Register C1, cycle the compressor on and off three times, then resume normal operation. | F23-S |
| C1 | The compressor cycle is abnormal or defective. | Continue normal operation; the error ends when defrost sensor temperature falls below minus 5 degrees Celsius. | FRS-2021 |
| C1 | Defrost sensor exceeds minus five degrees Celsius while the compressor runs over three hours. | The system continues normal operation; cancellation occurs when conditions return to normal. | FN-510DW |
| C1 | Cycle abnormal or defective. | RFS-26D1T | |
| C1 | Compressor ran at least three hours while the D sensor measured minus 5 °C or higher. | Continue normal operation; cancel when the compressor is off and D sensor is below minus 5 °C. | Refrigerator |
| C1 | Compressor cycle abnormal or defective. | Check for refrigerant leakage. | FRN-U20DB |
| C1 | Compressor runs over three hours while D-Sensor is at least minus 5 °C. | Continue normal operation; terminates when D-Sensor reaches at least minus 5 °C with compressor off. | FR-631ND |
| C1 | After three compressor hours, D sensor temperature is minus 5 °C or higher. | Normal operation continues; cancellation occurs below minus 5 °C with compressor off. | FRQ501DF01 |
| C 1 (2 Fridge) | Refrigerator cooling cycle fault. | Check after the first defrost mode. | FR-581NT |
| C2 | During defrost, sensors detect abnormal evaporator and temperature readings. | Register C2, pre cool, run the heater, then complete the remaining defrost cycle. | F23-S |
| C3 | Defrost heater operation is defective. | Register C3 and complete the remaining defrost cycle. | F23-S |
| C4 | Temperature remains over 18 °F above its set point for four hours. | Register C4, cycle the compressor three times, then return to normal mode. | F23-S |
| C5 | D sensor reads above 140 °F or below 55.4 °F for one minute. | Register C5 and end defrost by time after 30 minutes. | F23-S |
| CE | Front board received no data from RX for 30 seconds. | Refrigerator | |
| CE | Front unit receives no data from RX for 30 seconds. | FRQ501DF01 | |
| D 0 (1 Fridge) | Refrigerator door switch fault. | FR-581NT | |
| D1 | Defrost sensor is open or shorted. | The system returns defrost operation to the 30 minute limit; normal sensor operation cancels it. | ERF-36.A..EU, FN-510DW |
| d1 | D-sensor is disconnected or shorted. | Limit defrost return to 30 minutes; normal sensor operation ends the error. | FRS-2021 |
| d1 | D sensor is disconnected or short circuited. | Turn the defrost heater on for 30 minutes; cancellation is automatic when normal. | Refrigerator, FRQ501DF01 |
| d1 | D sensor disconnected or shorted. | Replace the evaporator D sensor if disconnected or shorted. | FRN-U20DB |
| d1 | D-Sensor is disconnected or short-circuited. | Limit defrost return time to 40 minutes; resets automatically when the sensor is normal. | FR-631ND |
| D 1 (E.R) | Defrost sensor fault. | Keep the heater on for 35 minutes only. | FR-581NT |
| D2 | Heater switched off after 80 minutes. | The system returns defrost operation to the 80 minute limit. | ERF-36.A..EU |
| d2 | Forced defrosting mode for service. | Use the specified button sequence for forced defrosting; the mode ends above 10 degrees Celsius. | FRS-2021 |
| D2 | Display forced defrost mode for service. | RFS-26D1T | |
| D2 | Appliance is in forced service mode. | Refrigerator | |
| D2 | Automatic service forced mode is active. | FRQ501DF01 | |
| d3 | Forced defrosting is active for power consumption control. | Refrigerator | |
| d3 | Power consuming forced defrosting is active. | FRQ501DF01 | |
| dF | Freezer door switch is defective. | Disable functions related to door-switch sensing; opening and closing the door ends the error. | FRS-2021 |
| dF | Freezer door switch defective. | RFS-26D1T, FRN-U20DB | |
| dF | Freezer door has remained open for at least one hour. | Ignore door switch related functions; cancellation occurs when door opening or closing is detected. | Refrigerator |
| dF | Freezer door remains open for at least one hour. | Door switch functions are ignored until opening or closing is detected. | FRQ501DF01 |
| DF1 | After-service compulsory defrosting mode. | Start by pressing REF.SET five times while pressing FRZ.SET; terminates when D-Sensor exceeds 10 °C. | FR-631ND |
| dH | Homebar door switch is defective. | Disable functions related to door-switch sensing; opening and closing the door ends the error. | FRS-2021 |
| dH | Home bar door has remained open for at least one hour. | Ignore door switch related functions; cancellation occurs when door opening or closing is detected. | Refrigerator |
| dH | Home bar door switch defective. | Check whether the door is open. | FRN-U20DB |
| dH | Home bar door remains open for at least one hour. | Door switch functions are ignored until opening or closing is detected. | FRQ501DF01 |
| door | Door remains open for more than one hour. | Door switch sensing functions are disabled; display terminates after showing on the C-LED. | FR-631ND |
| dr | Refrigerator door switch is defective. | Disable functions related to door-switch sensing; opening and closing the door ends the error. | FRS-2021 |
| DR | Door has remained open for more than one hour. | Open and close the door to terminate the error automatically. | FN-510DW |
| dr | Refrigerator door switch defective. | RFS-26D1T, FRN-U20DB | |
| dr | Refrigerator door has remained open for at least one hour. | Ignore door switch related functions; cancellation occurs when door opening or closing is detected. | Refrigerator |
| dr | Refrigerator door remains open for at least one hour. | Door switch functions are ignored until opening or closing is detected. | FRQ501DF01 |
| EA | Drops ice while Et is active. | FRN-U20DB | |
| EF | Flow sensor defective. | FRN-U20DB | |
| Eg | I sensor temperature fails to rise sufficiently after water supply. | Refrigerator, FRQ501DF01 | |
| Eg | Water supply error. | FRN-U20DB | |
| Ei | I sensor is disconnected or short circuited. | Refrigerator, FRQ501DF01 | |
| EI | I sensor disconnected or shorted. | FRN-U20DB | |
| EP | EEPROM read or write error occurred. | Refrigerator | |
| EP | EEPROM read or write error. | FRQ501DF01 | |
| ES | Water, crushed ice, or cube ice error. | RFS-26D1T | |
| ES | Micro switch error. | FRN-U20DB | |
| Et | Horizontal switch error. | FRN-U20DB | |
| Eu | Full ice switch error. | FRN-U20DB | |
| F1 | F-sensor is disconnected or shorted. | Operate compressor and freezer fan 25 minutes on, then 25 minutes off; normal sensor operation ends the error. | FRS-2021 |
| F1 | F-sensor disconnected or shorted. | Replace the F-sensor in the freezer compartment if disconnected or shorted. | RFS-26D1T |
| F1 | F sensor is disconnected or short circuited. | Operate the freezer fan and compressor according to room temperature sensor readings; cancellation is automatic when normal. | Refrigerator, FRQ501DF01 |
| F1 | F sensor disconnected or shorted. | Replace the freezer compartment F sensor if disconnected or shorted. | FRN-U20DB |
| F1 | F-Sensor is disconnected or short-circuited. | Run compressor and freezer fan 40 minutes on, then 20 minutes off; resets when sensor normal. | FR-631ND |
| F 1 (FRZ.) | Freezer sensor fault. | Run the compressor and freezer fan 24 minutes, then stop them 16 minutes. | FR-581NT |
| F3 | Defrost return is abnormal or defective. | Disable precooling during defrost; sensor controlled defrost return ends the error. | FRS-2021 |
| F3 | Defrost fault requiring the next limit defrost time. | During defrost, delete pre cooling; cancellation occurs when defrost completes through the defrost sensor. | FN-510DW |
| F3 | Freezer defrost return abnormal or defective. | RFS-26D1T | |
| F3 | Defrosting ended because the time limit was reached due to the D sensor. | Continue normal operation; cancellation is automatic when defrosting ends through the D sensor. | Refrigerator |
| F3 | Defrost return abnormal or defective. | Measure defrost heater resistance; replace it if open or shorted. | FRN-U20DB |
| F3 | Defrosting returns by the 80-minute limit. | Delete pre-cooling during defrosting; terminates when defrosting returns by D-Sensor. | FR-631ND |
| F3 | Defrosting returns by the time limit because of the D sensor. | Normal operation continues; it cancels when the D sensor ends defrosting. | FRQ501DF01 |
| F 3 (3 Fridge) | Refrigerator defrost heater fault. | Allow natural defrost for 80 minutes. | FR-581NT |
| FD | FD-sensor disconnected or shorted. | Replace the FD-sensor on the evaporator if disconnected or shorted. | RFS-26D1T |
| HS | Humidity sensor is disconnected or short circuited. | Refrigerator, FRQ501DF01 | |
| i5 | IM-sensor disconnected or shorted. | Replace the IM-sensor in the fridge compartment if disconnected or shorted. | RFS-26D1T |
| iD | IR-sensor disconnected or shorted. | Replace the IR-sensor on the evaporator if disconnected or shorted. | RFS-26D1T |
| R1 | Refrigerator sensor is open or shorted. | The system controls operation according to room temperature; normal sensor operation cancels the error. | ERF-36.A..EU, FN-510DW |
| r1 | R-sensor is disconnected or shorted. | Use ambient-temperature control; normal sensor operation ends the error. | FRS-2021 |
| r1 | R-sensor disconnected or shorted. | Replace the R-sensor in the fridge compartment if disconnected or shorted. | RFS-26D1T |
| r1 | R sensor is disconnected or short circuited. | Operate the freezer fan and compressor according to room temperature sensor readings; cancellation is automatic when normal. | Refrigerator, FRQ501DF01 |
| r1 | R sensor disconnected or shorted. | Replace the refrigerator compartment sensor if disconnected or shorted. | FRN-U20DB |
| r1 | R-Sensor is disconnected or short-circuited. | Control by ambient temperature; resets automatically when the R-Sensor is normal. | FR-631ND |
| R 1 (REF.) | Refrigerator sensor fault. | Use the R2 sensor for control. | FR-581NT |
| R 2 (Q.R) | R2 sensor fault. | FR-581NT | |
| r3 | Refrigerator defrost return abnormal or defective. | RFS-26D1T | |
| rD | RD-sensor disconnected or shorted. | Replace the RD-sensor on the evaporator if disconnected or shorted. | RFS-26D1T |
| RT | Room temperature sensor is open or shorted. | The system continues normally without refrigerator sensor control; normal sensor operation cancels the error. | ERF-36.A..EU |
| rt | RT-sensor is disconnected or shorted. | Continue normal operation without RT-sensor control; normal sensor operation ends the error. | FRS-2021 |
| RT | RT sensor is open or shorted. | Normal operation resumes when the RT sensor works normally. | FN-510DW |
| rt | RT-sensor disconnected or shorted. | Replace the RT-sensor on the specified location if disconnected or shorted. | RFS-26D1T |
| rt | RT sensor is disconnected or short circuited. | Continue normal operation while ignoring RT sensor controls; cancellation is automatic when normal. | Refrigerator, FRQ501DF01 |
| rt | RT sensor disconnected or shorted. | Replace the RT sensor if voltage is 0V or 5V. | FRN-U20DB |
| rt | RT-Sensor is disconnected or short-circuited. | Continue normal operation; resets automatically when the RT-Sensor is normal. | FR-631ND |
| RT (E.R) | Room temperature sensor fault. | FR-581NT |