CodeMeaningWhat to doManual
33Temperature display indicates sensor disconnection or short circuit.Refrigerator
33Temperature display shows sensor disconnection or short circuit.FRQ501DF01
C1Freezer compressor fails to run for 60 minutes after switching off.Register C1, cycle the compressor on and off three times, then resume normal operation.F23-S
C1The compressor cycle is abnormal or defective.Continue normal operation; the error ends when defrost sensor temperature falls below minus 5 degrees Celsius.FRS-2021
C1Defrost sensor exceeds minus five degrees Celsius while the compressor runs over three hours.The system continues normal operation; cancellation occurs when conditions return to normal.FN-510DW
C1Cycle abnormal or defective.RFS-26D1T
C1Compressor ran at least three hours while the D sensor measured minus 5 °C or higher.Continue normal operation; cancel when the compressor is off and D sensor is below minus 5 °C.Refrigerator
C1Compressor cycle abnormal or defective.Check for refrigerant leakage.FRN-U20DB
C1Compressor runs over three hours while D-Sensor is at least minus 5 °C.Continue normal operation; terminates when D-Sensor reaches at least minus 5 °C with compressor off.FR-631ND
C1After three compressor hours, D sensor temperature is minus 5 °C or higher.Normal operation continues; cancellation occurs below minus 5 °C with compressor off.FRQ501DF01
C 1 (2 Fridge)Refrigerator cooling cycle fault.Check after the first defrost mode.FR-581NT
C2During defrost, sensors detect abnormal evaporator and temperature readings.Register C2, pre cool, run the heater, then complete the remaining defrost cycle.F23-S
C3Defrost heater operation is defective.Register C3 and complete the remaining defrost cycle.F23-S
C4Temperature remains over 18 °F above its set point for four hours.Register C4, cycle the compressor three times, then return to normal mode.F23-S
C5D sensor reads above 140 °F or below 55.4 °F for one minute.Register C5 and end defrost by time after 30 minutes.F23-S
CEFront board received no data from RX for 30 seconds.Refrigerator
CEFront unit receives no data from RX for 30 seconds.FRQ501DF01
D 0 (1 Fridge)Refrigerator door switch fault.FR-581NT
D1Defrost sensor is open or shorted.The system returns defrost operation to the 30 minute limit; normal sensor operation cancels it.ERF-36.A..EU, FN-510DW
d1D-sensor is disconnected or shorted.Limit defrost return to 30 minutes; normal sensor operation ends the error.FRS-2021
d1D sensor is disconnected or short circuited.Turn the defrost heater on for 30 minutes; cancellation is automatic when normal.Refrigerator, FRQ501DF01
d1D sensor disconnected or shorted.Replace the evaporator D sensor if disconnected or shorted.FRN-U20DB
d1D-Sensor is disconnected or short-circuited.Limit defrost return time to 40 minutes; resets automatically when the sensor is normal.FR-631ND
D 1 (E.R)Defrost sensor fault.Keep the heater on for 35 minutes only.FR-581NT
D2Heater switched off after 80 minutes.The system returns defrost operation to the 80 minute limit.ERF-36.A..EU
d2Forced defrosting mode for service.Use the specified button sequence for forced defrosting; the mode ends above 10 degrees Celsius.FRS-2021
D2Display forced defrost mode for service.RFS-26D1T
D2Appliance is in forced service mode.Refrigerator
D2Automatic service forced mode is active.FRQ501DF01
d3Forced defrosting is active for power consumption control.Refrigerator
d3Power consuming forced defrosting is active.FRQ501DF01
dFFreezer door switch is defective.Disable functions related to door-switch sensing; opening and closing the door ends the error.FRS-2021
dFFreezer door switch defective.RFS-26D1T, FRN-U20DB
dFFreezer door has remained open for at least one hour.Ignore door switch related functions; cancellation occurs when door opening or closing is detected.Refrigerator
dFFreezer door remains open for at least one hour.Door switch functions are ignored until opening or closing is detected.FRQ501DF01
DF1After-service compulsory defrosting mode.Start by pressing REF.SET five times while pressing FRZ.SET; terminates when D-Sensor exceeds 10 °C.FR-631ND
dHHomebar door switch is defective.Disable functions related to door-switch sensing; opening and closing the door ends the error.FRS-2021
dHHome bar door has remained open for at least one hour.Ignore door switch related functions; cancellation occurs when door opening or closing is detected.Refrigerator
dHHome bar door switch defective.Check whether the door is open.FRN-U20DB
dHHome bar door remains open for at least one hour.Door switch functions are ignored until opening or closing is detected.FRQ501DF01
doorDoor remains open for more than one hour.Door switch sensing functions are disabled; display terminates after showing on the C-LED.FR-631ND
drRefrigerator door switch is defective.Disable functions related to door-switch sensing; opening and closing the door ends the error.FRS-2021
DRDoor has remained open for more than one hour.Open and close the door to terminate the error automatically.FN-510DW
drRefrigerator door switch defective.RFS-26D1T, FRN-U20DB
drRefrigerator door has remained open for at least one hour.Ignore door switch related functions; cancellation occurs when door opening or closing is detected.Refrigerator
drRefrigerator door remains open for at least one hour.Door switch functions are ignored until opening or closing is detected.FRQ501DF01
EADrops ice while Et is active.FRN-U20DB
EFFlow sensor defective.FRN-U20DB
EgI sensor temperature fails to rise sufficiently after water supply.Refrigerator, FRQ501DF01
EgWater supply error.FRN-U20DB
EiI sensor is disconnected or short circuited.Refrigerator, FRQ501DF01
EII sensor disconnected or shorted.FRN-U20DB
EPEEPROM read or write error occurred.Refrigerator
EPEEPROM read or write error.FRQ501DF01
ESWater, crushed ice, or cube ice error.RFS-26D1T
ESMicro switch error.FRN-U20DB
EtHorizontal switch error.FRN-U20DB
EuFull ice switch error.FRN-U20DB
F1F-sensor is disconnected or shorted.Operate compressor and freezer fan 25 minutes on, then 25 minutes off; normal sensor operation ends the error.FRS-2021
F1F-sensor disconnected or shorted.Replace the F-sensor in the freezer compartment if disconnected or shorted.RFS-26D1T
F1F sensor is disconnected or short circuited.Operate the freezer fan and compressor according to room temperature sensor readings; cancellation is automatic when normal.Refrigerator, FRQ501DF01
F1F sensor disconnected or shorted.Replace the freezer compartment F sensor if disconnected or shorted.FRN-U20DB
F1F-Sensor is disconnected or short-circuited.Run compressor and freezer fan 40 minutes on, then 20 minutes off; resets when sensor normal.FR-631ND
F 1 (FRZ.)Freezer sensor fault.Run the compressor and freezer fan 24 minutes, then stop them 16 minutes.FR-581NT
F3Defrost return is abnormal or defective.Disable precooling during defrost; sensor controlled defrost return ends the error.FRS-2021
F3Defrost fault requiring the next limit defrost time.During defrost, delete pre cooling; cancellation occurs when defrost completes through the defrost sensor.FN-510DW
F3Freezer defrost return abnormal or defective.RFS-26D1T
F3Defrosting ended because the time limit was reached due to the D sensor.Continue normal operation; cancellation is automatic when defrosting ends through the D sensor.Refrigerator
F3Defrost return abnormal or defective.Measure defrost heater resistance; replace it if open or shorted.FRN-U20DB
F3Defrosting returns by the 80-minute limit.Delete pre-cooling during defrosting; terminates when defrosting returns by D-Sensor.FR-631ND
F3Defrosting returns by the time limit because of the D sensor.Normal operation continues; it cancels when the D sensor ends defrosting.FRQ501DF01
F 3 (3 Fridge)Refrigerator defrost heater fault.Allow natural defrost for 80 minutes.FR-581NT
FDFD-sensor disconnected or shorted.Replace the FD-sensor on the evaporator if disconnected or shorted.RFS-26D1T
HSHumidity sensor is disconnected or short circuited.Refrigerator, FRQ501DF01
i5IM-sensor disconnected or shorted.Replace the IM-sensor in the fridge compartment if disconnected or shorted.RFS-26D1T
iDIR-sensor disconnected or shorted.Replace the IR-sensor on the evaporator if disconnected or shorted.RFS-26D1T
R1Refrigerator sensor is open or shorted.The system controls operation according to room temperature; normal sensor operation cancels the error.ERF-36.A..EU, FN-510DW
r1R-sensor is disconnected or shorted.Use ambient-temperature control; normal sensor operation ends the error.FRS-2021
r1R-sensor disconnected or shorted.Replace the R-sensor in the fridge compartment if disconnected or shorted.RFS-26D1T
r1R sensor is disconnected or short circuited.Operate the freezer fan and compressor according to room temperature sensor readings; cancellation is automatic when normal.Refrigerator, FRQ501DF01
r1R sensor disconnected or shorted.Replace the refrigerator compartment sensor if disconnected or shorted.FRN-U20DB
r1R-Sensor is disconnected or short-circuited.Control by ambient temperature; resets automatically when the R-Sensor is normal.FR-631ND
R 1 (REF.)Refrigerator sensor fault.Use the R2 sensor for control.FR-581NT
R 2 (Q.R)R2 sensor fault.FR-581NT
r3Refrigerator defrost return abnormal or defective.RFS-26D1T
rDRD-sensor disconnected or shorted.Replace the RD-sensor on the evaporator if disconnected or shorted.RFS-26D1T
RTRoom temperature sensor is open or shorted.The system continues normally without refrigerator sensor control; normal sensor operation cancels the error.ERF-36.A..EU
rtRT-sensor is disconnected or shorted.Continue normal operation without RT-sensor control; normal sensor operation ends the error.FRS-2021
RTRT sensor is open or shorted.Normal operation resumes when the RT sensor works normally.FN-510DW
rtRT-sensor disconnected or shorted.Replace the RT-sensor on the specified location if disconnected or shorted.RFS-26D1T
rtRT sensor is disconnected or short circuited.Continue normal operation while ignoring RT sensor controls; cancellation is automatic when normal.Refrigerator, FRQ501DF01
rtRT sensor disconnected or shorted.Replace the RT sensor if voltage is 0V or 5V.FRN-U20DB
rtRT-Sensor is disconnected or short-circuited.Continue normal operation; resets automatically when the RT-Sensor is normal.FR-631ND
RT (E.R)Room temperature sensor fault.FR-581NT