Have a question about the Daewoo FRQ501DF01? The AI assistant looks through this manual and shows the pages with the answer.
Same manual for other models
These manuals share their text with this one.
| Daewoo RefrigeratorRefrigerator | Same manual | Service Manual · 112 pages |
|---|
Daewoo FRQ501DF01 questions
Answers taken from this manual. Each one links to the page it comes from.
How often does the door-open buzzer sound?
Every minute for 5 min. while a door is open.
Manual: page 24
How do I fix a severe height difference with the Fridge door lower?
Use the lower-hinge adjustment when the adjustment foot cannot correct the door height.
- First adjust the Fridge adjustment foot; continue if it cannot correct horizontality.
- Open the doors and separate the front panel cover if the refrigerator was moved after installation.
- Place the wrench on the Fridge door-hinge nut and turn clockwise to loosen it.
- Place the wrench on the Fridge lower hinge shaft and turn counterclockwise to raise the door.
- Place the wrench on the hinge nut and turn counterclockwise to tighten it firmly.
Manual: page 99
Why are the refrigerator lights off?
The refrigerator may not have power. Check the power cord connection.
Manual: page 43
How do I read the refrigerator’s sensor temperatures?
- At the Locked state, press Freezer, then touch Lock Setup five times.
- The display begins with refrigerator operation time.
- Press Freezer repeatedly to view each sensor temperature in sequence.
- Touch Lock Function once to cancel, or wait 4 min. for automatic cancellation.
Manual: page 38
How do I cancel Demo Function?
- Press Fridge Adjustment and Choose Freezing 5 times.
- Reset the power supply.
Manual: page 27
How do I run the ice maker's test mode?
- Press the ice maker's Test S/W for more than one second.
- The test starts from Ice Separation mode.
- If Test S/W has a short-circuit error, testing runs only once.
Manual: page 28
Why do the compressor and freezer fan stop during defrosting?
They can be off during the 10-minute pause, while the defrosting heater is also off.
Manual: page 21
What time limits does the defrosting process use?
The defrosting process uses these phase time limits.
| Phase | Time limit |
|---|---|
| Precool | 50 minutes |
| Defrosting | 60 minutes |
| Pause | 10 minutes |
| Fan Delay | 5 minutes |
Manual: page 21
Error codes in this manual
| Code | Meaning | What to do | |
|---|---|---|---|
| 33 | Temperature display shows sensor disconnection or short circuit. | p. 34 | |
| C1 | After three compressor hours, D sensor temperature is minus 5 °C or higher. | Normal operation continues; cancellation occurs below minus 5 °C with compressor off. | p. 34 |
| CE | Front unit receives no data from RX for 30 seconds. | p. 34 | |
| d1 | D sensor is disconnected or short circuited. | Turn the D heater on for 30 minutes. | p. 34 |
| D2 | Automatic service forced mode is active. | p. 34 | |
| d3 | Power consuming forced defrosting is active. | p. 34 | |
| dF | Freezer door remains open for at least one hour. | Door switch functions are ignored until opening or closing is detected. | p. 34 |
| dH | Home bar door remains open for at least one hour. | Door switch functions are ignored until opening or closing is detected. | p. 34 |
| dr | Refrigerator door remains open for at least one hour. | Door switch functions are ignored until opening or closing is detected. | p. 34 |
| Eg | I sensor temperature fails to rise sufficiently after water supply. | p. 34 | |
| Ei | I sensor is disconnected or short circuited. | p. 34 | |
| EP | EEPROM read or write error. | p. 34 | |
| F1 | F sensor is disconnected or short circuited. | It cancels automatically when the F sensor becomes normal. | p. 34 |
| F3 | Defrosting returns by the time limit because of the D sensor. | Normal operation continues; it cancels when the D sensor ends defrosting. | p. 34 |
| HS | Humidity sensor is disconnected or short circuited. | p. 34 | |
| r1 | R sensor is disconnected or short circuited. | It cancels automatically when the R sensor becomes normal. | p. 34 |
| rt | RT sensor is disconnected or short circuited. | Normal operation continues while ignoring RT sensor controls. | p. 34 |
Similar Daewoo refrigerators
| Daewoo FRN-U20DB | Service Manual | 92 pages |
|---|---|---|
| Daewoo FRSU20IA01 | Service Manual | 56 pages |
| Daewoo FR-631ND | Service Manual | 44 pages |
| Daewoo FN-510DW | Service Manual | 31 pages |
| Daewoo FR-581NT | Service Manual | 31 pages |
| Daewoo DRX32DDL | User Manual | 18 pages |
| Daewoo 272SVC | Service Manual | 14 pages |
| Daewoo 272SVC | Service Manual | 13 pages |