Key numbers from this manual
As printed in the manual, with metric and US units side by side. The typical range comes from all portable / rv refrigerator manuals on this site that print the same figure.
| Door-open alarm after | more than 2 minutesThe door remains open | p. 33 |
|---|
Dometic 10-SERIES questions
Answers taken from this manual. Each one links to the page it comes from.
What temperature setting should I use at moderate room temperatures?
Select the average temperature setting for ambient temperatures of +15 °C to +25 °C.
Manual: page 18
What should I do if frost is affecting cooling?
Defrost the refrigerator. An iced evaporator can reduce cooling, so check the door closure and seal condition first.
Manual: page 32
When should I defrost the refrigerator?
Defrost when frost on the cooling fins reaches about 3 mm; never use mechanical tools or a hair dryer to remove ice.
Manual: page 29
How do I reset an ERROR fault on RMD10.5T or RMD10.5XT?
Press the control knob for 2 seconds to reset the fault.
- Press the control knob for 2 seconds.
- Listen for the beep confirming the error reset.
Manual: page 33
Why does the refrigerator fault beep return every 30 minutes?
The fault has not been corrected; the beep lasts 2 minutes and repeats every 30 minutes until it is fixed.
Manual: page 32
What does the battery symbol mean on this refrigerator?
It lights when optional battery packs are installed and the refrigerator runs in stand-alone gas mode.
Manual: page 20
Error codes in this manual
| Code | Meaning | What to do | |
|---|---|---|---|
| E03 | No connection exists between the power module and display. | Contact an authorized customer service. | p. 34 |
| E07 | No cooling capacity is available in gas mode. | Level the device, reset the error, and contact customer service if repeated. | p. 34 |
| E08 | No cooling power is available in AC mode. | Level the device, reset the error, and contact customer service if repeated. | p. 34 |
| E09 | No cooling power is available in DC mode. | Level the device, reset the error, and contact customer service if repeated. | p. 34 |
| E12 | The gas valve check has failed. | Reset the error and contact customer service if it occurs again. | p. 34 |
| E13 | An internal communication error prevents gas operation. | Reset the error and contact customer service if it occurs again. | p. 34 |
| E14 | Battery packs have too little charge in standalone gas mode. | Insert new batteries, then reset the error. | p. 34 |
| E50 | Gas is locked after three ignition attempts. | Replace the empty gas cylinder and reset the error. | p. 34 |
| E51 | A gas lock results from an internal power module error. | Reset the error and contact customer service if it occurs again. | p. 35 |
| E52 | A ground contact fault affects the gas valve. | Reset the error and contact customer service if it occurs again. | p. 35 |
| E53 | A ground contact fault affects the ignition electrode. | Reset the error and contact customer service if it occurs again. | p. 35 |
Similar Dometic portable & rv fridges
| Dometic 10-SERIESModel family 10SERIES | Operating Instructions | 624 pages |
|---|---|---|
| Dometic 10-SERIESModel family 10SERIES | Operating Instructions | 124 pages |
| Dometic RMD8501Model family RMD | Operating Instructions | 28 pages |
| Dometic RM8400 | Operating Instructions | 64 pages |
| Dometic RM8501 | Operating Instructions | 56 pages |
| Dometic RML9430 | Operating Instructions | 44 pages |
| Dometic RM5310 | Operating Instructions | 32 pages |
| Dometic DM2652 | Operating Instructions | 26 pages |