Door-open alarm aftermore than 2 minutesThe door remains openp. 33

Dometic 10-SERIES questions

Answers taken from this manual. Each one links to the page it comes from.

What temperature setting should I use at moderate room temperatures?

Select the average temperature setting for ambient temperatures of +15 °C to +25 °C.

Manual: page 18

What should I do if frost is affecting cooling?

Defrost the refrigerator. An iced evaporator can reduce cooling, so check the door closure and seal condition first.

Manual: page 32

When should I defrost the refrigerator?

Defrost when frost on the cooling fins reaches about 3 mm; never use mechanical tools or a hair dryer to remove ice.

Manual: page 29

How do I reset an ERROR fault on RMD10.5T or RMD10.5XT?

Press the control knob for 2 seconds to reset the fault.

  1. Press the control knob for 2 seconds.
  2. Listen for the beep confirming the error reset.

Manual: page 33

Why does the refrigerator fault beep return every 30 minutes?

The fault has not been corrected; the beep lasts 2 minutes and repeats every 30 minutes until it is fixed.

Manual: page 32

What does the battery symbol mean on this refrigerator?

It lights when optional battery packs are installed and the refrigerator runs in stand-alone gas mode.

Manual: page 20

Error codes in this manual

CodeMeaningWhat to do
E03No connection exists between the power module and display.Contact an authorized customer service.p. 34
E07No cooling capacity is available in gas mode.Level the device, reset the error, and contact customer service if repeated.p. 34
E08No cooling power is available in AC mode.Level the device, reset the error, and contact customer service if repeated.p. 34
E09No cooling power is available in DC mode.Level the device, reset the error, and contact customer service if repeated.p. 34
E12The gas valve check has failed.Reset the error and contact customer service if it occurs again.p. 34
E13An internal communication error prevents gas operation.Reset the error and contact customer service if it occurs again.p. 34
E14Battery packs have too little charge in standalone gas mode.Insert new batteries, then reset the error.p. 34
E50Gas is locked after three ignition attempts.Replace the empty gas cylinder and reset the error.p. 34
E51A gas lock results from an internal power module error.Reset the error and contact customer service if it occurs again.p. 35
E52A ground contact fault affects the gas valve.Reset the error and contact customer service if it occurs again.p. 35
E53A ground contact fault affects the ignition electrode.Reset the error and contact customer service if it occurs again.p. 35
All Dometic error codes →

Similar Dometic portable & rv fridges

Dometic 10-SERIESModel family 10SERIESOperating Instructions624 pages
Dometic 10-SERIESModel family 10SERIESOperating Instructions124 pages
Dometic RMD8501Model family RMDOperating Instructions28 pages
Dometic RM8400Operating Instructions64 pages
Dometic RM8501Operating Instructions56 pages
Dometic RML9430Operating Instructions44 pages
Dometic RM5310Operating Instructions32 pages
Dometic DM2652Operating Instructions26 pages
All Dometic portable & rv fridges →