As printed in the manual, with metric and US units side by side. The typical range comes from all portable / rv refrigerator manuals on this site that print the same figure.
| Time to cool down | 12 hours longer than mostat the start of operationTypical for portable & rv fridges: 3.5 to 8 hours | p. 11 |
|---|
Dometic 10-SERIES questions
Answers taken from this manual. Each one links to the page it comes from.
When should I defrost the refrigerator?
Defrost the refrigerator when frost on the cooling fins reaches about 3 mm. Do not use mechanical tools or a hair dryer to remove ice.
Manual: page 22
Why is the refrigerator interior light off?
The refrigerator interior light stays off in stand-alone gas mode.
Manual: page 15
Why does the display turn off and briefly come back on?
In stand-alone gas mode, the display turns off 2 seconds after activity and briefly switches on every 15 seconds; pending errors keep it on.
Manual: page 15
How long should I wait before storing goods?
Wait 12 hours after operation starts before storing goods.
Manual: page 11
Error codes in this manual
| Code | Meaning | What to do | |
|---|---|---|---|
| E03 | Power module and display are not connected. | Contact an authorized customer service. | p. 28 |
| E07 | The refrigerator has no cooling capacity in gas mode. | Check and correct the appliance angle, reset the error, and contact service if repeated. | p. 28 |
| E08 | The refrigerator has no cooling power in AC mode. | Check and correct the appliance angle, reset the error, and contact service if repeated. | p. 28 |
| E09 | The refrigerator has no cooling power in DC mode. | Check and correct the appliance angle, reset the error, and contact service if repeated. | p. 29 |
| E12 | The gas valve check has failed. | Gas operation is unavailable. Reset the error and contact service if repeated. | p. 29 |
| E13 | An internal communication error has occurred. | Gas operation is unavailable. Reset the error and contact service if repeated. | p. 29 |
| E14 | Battery pack charge is too low in standalone gas mode. | Insert new batteries, then reset the error. | p. 29 |
| E50 | Gas is locked after three ignition attempts. | Replace the empty gas cylinder and reset the error. | p. 29 |
| E51 | Gas lock is caused by an internal power module error. | Reset the error and contact service if it happens again. | p. 29 |
| E52 | There is a ground contact fault at the gas valve. | Reset the error and contact service if it happens again. | p. 29 |
| E53 | There is a ground contact fault at the ignition electrode. | Reset the error and contact service if it happens again. | p. 29 |
| W01 | Temperature sensor in the refrigerator compartment is defective. | Contact an authorized customer service. | p. 28 |
| W05 | AC power is disconnected or voltage is below 190 volts. | Connect AC power or select gas or DC operation. | p. 28 |
| W06 | DC power is disconnected. | Connect DC power or select gas or AC operation. | p. 28 |
| W10 | The door has been open for more than two minutes. | Close the door. | p. 28 |
| W11 | DC supply voltage exceeds 16 volts. | Reduce the DC supply voltage. | p. 28 |
Similar Dometic portable & rv fridges
| Dometic 10-SERIESModel family 10SERIES | Operating Instructions | 624 pages |
|---|---|---|
| Dometic 10-SERIESModel family 10SERIES | Operating Instructions | 124 pages |
| Dometic RMD8501Model family RMD | Operating Instructions | 28 pages |
| Dometic RM8400 | Operating Instructions | 64 pages |
| Dometic RM8501 | Operating Instructions | 56 pages |
| Dometic RML9430 | Operating Instructions | 44 pages |
| Dometic RM5310 | Operating Instructions | 32 pages |
| Dometic DM2652 | Operating Instructions | 26 pages |