Dometic error codes

31 Dometic error and alarm codes from 7 manuals: what each code means and what the manual says to do.

31 codes7 manuals

Codes and what they mean

As described in each manual. The same code can mean different things on different models, so check the model column.

CodeMeaningWhat to doManual
E0No communication between the display and power modules.RM1350
E0Display and power module are not communicating.Contact a Dometic dealer or Service Center.RM3762
E03Power module and display are not connected.Contact an authorized customer service.10-SERIES
E03No connection exists between the power module and display.Contact an authorized customer service point.10-SERIES, 10-SERIES
E07The refrigerator has no cooling capacity in gas mode.Check and correct the appliance angle, reset the error, and contact service if repeated.10-SERIES
E07No cooling capacity in gas mode.Level the appliance, reset the error, and contact customer service if it returns.10-SERIES
E07No cooling capacity is available in gas mode.Level the device, reset the error, and contact customer service if repeated.10-SERIES
E08The refrigerator has no cooling power in AC mode.Check and correct the appliance angle, reset the error, and contact service if repeated.10-SERIES
E08No cooling capacity in AC power mode.Level the appliance, reset the error, and contact customer service if it returns.10-SERIES
E08No cooling power is available in AC mode.Level the device, reset the error, and contact customer service if repeated.10-SERIES
E09The refrigerator has no cooling power in DC mode.Check and correct the appliance angle, reset the error, and contact service if repeated.10-SERIES
E09No cooling capacity in DC power mode.Level the appliance, reset the error, and contact customer service if it returns.10-SERIES
E09No cooling power is available in DC mode.Level the device, reset the error, and contact customer service if repeated.10-SERIES
E1Hardware fault in the gas operating system.RM1350
E1LP gas valve is disconnected or the LP gas system has a hardware fault.Contact a Dometic dealer or Service Center.RM3762
E1Hot and neutral wires are reversed.Portable / RV Refrigerator
E2Temperature sensor or related electronic circuitry failure.RM1350
E2Temperature sensor or related electronic circuitry has failed.Ensure the sensor wire is connected; contact a Dometic dealer or Service Center.RM3762
E2Ground connection is missing.Portable / RV Refrigerator
E3Cooling unit has malfunctioned.Contact a Service Center.RM3762
E3Line 1 voltage exceeds 132 volts.Portable / RV Refrigerator
E4DC voltage is outside the permitted range.Contact a Dometic dealer or Service Center.RM3762
E4Line 1 voltage is below 104 volts.Portable / RV Refrigerator
E5Line 2 voltage exceeds 132 volts.Portable / RV Refrigerator
E6Line 2 voltage is below 104 volts.Portable / RV Refrigerator
E7Line frequency exceeds 69 cycles per second.Portable / RV Refrigerator
E8Line frequency is below 51 cycles per second.Portable / RV Refrigerator
E9The data link is disconnected.Call technical support.Portable / RV Refrigerator
E10The surge protector module requires replacement.Replace the module and call technical support.Portable / RV Refrigerator
E12The gas valve check has failed.Gas operation is unavailable. Reset the error and contact service if repeated.10-SERIES, 10-SERIES
E12Gas valve test error.Reset the error and contact customer service if it returns.10-SERIES
E13An internal communication error has occurred.Gas operation is unavailable. Reset the error and contact service if repeated.10-SERIES
E13Internal communication error.Reset the error and contact customer service if it returns.10-SERIES
E13An internal communication error prevents gas operation.Reset the error and contact customer service if it occurs again.10-SERIES
E14Battery pack charge is too low in standalone gas mode.Insert new batteries, then reset the error.10-SERIES
E14Battery pack charge is too low in stand alone gas mode.Insert new batteries, then reset the error.10-SERIES
E14Battery packs have too little charge in standalone gas mode.Insert new batteries, then reset the error.10-SERIES
E50Gas is locked after three ignition attempts.Replace the empty gas cylinder and reset the error.10-SERIES, 10-SERIES
E50Gas lock occurred after three ignition attempts.Replace the empty gas cylinder, then reset the error.10-SERIES
E51Gas lock is caused by an internal power module error.Reset the error and contact service if it happens again.10-SERIES
E51Gas lock caused by an internal power module error.Reset the error and contact customer service if it returns.10-SERIES
E51A gas lock results from an internal power module error.Reset the error and contact customer service if it occurs again.10-SERIES
E52There is a ground contact fault at the gas valve.Reset the error and contact service if it happens again.10-SERIES
E52Ground contact involving the gas valve.Reset the error and contact customer service if it returns.10-SERIES
E52A ground contact fault affects the gas valve.Reset the error and contact customer service if it occurs again.10-SERIES
E53There is a ground contact fault at the ignition electrode.Reset the error and contact service if it happens again.10-SERIES
E53Ground contact involving the ignition electrode.Reset the error and contact customer service if it returns.10-SERIES
E53A ground contact fault affects the ignition electrode.Reset the error and contact customer service if it occurs again.10-SERIES
Err1An error has occurred.CF11-O-AUS
Err2An error has occurred.CF11-O-AUS
FLGas problem after unsuccessful ignition attempt.Check the gas supply.RM1350
PE 4Previous shutdown resulted from low voltage on Line 1.Portable / RV Refrigerator
W01Temperature sensor in the refrigerator compartment is defective.Contact an authorized customer service.10-SERIES
W05AC power is disconnected or voltage is below 190 volts.Connect AC power or select gas or DC operation.10-SERIES
W06DC power is disconnected.Connect DC power or select gas or AC operation.10-SERIES
W10The door has been open for more than two minutes.Close the door.10-SERIES
W11DC supply voltage exceeds 16 volts.Reduce the DC supply voltage.10-SERIES

Error codes of other brands