| Code | Meaning | What to do | Manual |
|---|---|---|---|
| E0 | No communication between the display and power modules. | RM1350 | |
| E0 | Display and power module are not communicating. | Contact a Dometic dealer or Service Center. | RM3762 |
| E03 | Power module and display are not connected. | Contact an authorized customer service. | 10-SERIES |
| E03 | No connection exists between the power module and display. | Contact an authorized customer service point. | 10-SERIES, 10-SERIES |
| E07 | The refrigerator has no cooling capacity in gas mode. | Check and correct the appliance angle, reset the error, and contact service if repeated. | 10-SERIES |
| E07 | No cooling capacity in gas mode. | Level the appliance, reset the error, and contact customer service if it returns. | 10-SERIES |
| E07 | No cooling capacity is available in gas mode. | Level the device, reset the error, and contact customer service if repeated. | 10-SERIES |
| E08 | The refrigerator has no cooling power in AC mode. | Check and correct the appliance angle, reset the error, and contact service if repeated. | 10-SERIES |
| E08 | No cooling capacity in AC power mode. | Level the appliance, reset the error, and contact customer service if it returns. | 10-SERIES |
| E08 | No cooling power is available in AC mode. | Level the device, reset the error, and contact customer service if repeated. | 10-SERIES |
| E09 | The refrigerator has no cooling power in DC mode. | Check and correct the appliance angle, reset the error, and contact service if repeated. | 10-SERIES |
| E09 | No cooling capacity in DC power mode. | Level the appliance, reset the error, and contact customer service if it returns. | 10-SERIES |
| E09 | No cooling power is available in DC mode. | Level the device, reset the error, and contact customer service if repeated. | 10-SERIES |
| E1 | Hardware fault in the gas operating system. | RM1350 | |
| E1 | LP gas valve is disconnected or the LP gas system has a hardware fault. | Contact a Dometic dealer or Service Center. | RM3762 |
| E1 | Hot and neutral wires are reversed. | Portable / RV Refrigerator | |
| E2 | Temperature sensor or related electronic circuitry failure. | RM1350 | |
| E2 | Temperature sensor or related electronic circuitry has failed. | Ensure the sensor wire is connected; contact a Dometic dealer or Service Center. | RM3762 |
| E2 | Ground connection is missing. | Portable / RV Refrigerator | |
| E3 | Cooling unit has malfunctioned. | Contact a Service Center. | RM3762 |
| E3 | Line 1 voltage exceeds 132 volts. | Portable / RV Refrigerator | |
| E4 | DC voltage is outside the permitted range. | Contact a Dometic dealer or Service Center. | RM3762 |
| E4 | Line 1 voltage is below 104 volts. | Portable / RV Refrigerator | |
| E5 | Line 2 voltage exceeds 132 volts. | Portable / RV Refrigerator | |
| E6 | Line 2 voltage is below 104 volts. | Portable / RV Refrigerator | |
| E7 | Line frequency exceeds 69 cycles per second. | Portable / RV Refrigerator | |
| E8 | Line frequency is below 51 cycles per second. | Portable / RV Refrigerator | |
| E9 | The data link is disconnected. | Call technical support. | Portable / RV Refrigerator |
| E10 | The surge protector module requires replacement. | Replace the module and call technical support. | Portable / RV Refrigerator |
| E12 | The gas valve check has failed. | Gas operation is unavailable. Reset the error and contact service if repeated. | 10-SERIES, 10-SERIES |
| E12 | Gas valve test error. | Reset the error and contact customer service if it returns. | 10-SERIES |
| E13 | An internal communication error has occurred. | Gas operation is unavailable. Reset the error and contact service if repeated. | 10-SERIES |
| E13 | Internal communication error. | Reset the error and contact customer service if it returns. | 10-SERIES |
| E13 | An internal communication error prevents gas operation. | Reset the error and contact customer service if it occurs again. | 10-SERIES |
| E14 | Battery pack charge is too low in standalone gas mode. | Insert new batteries, then reset the error. | 10-SERIES |
| E14 | Battery pack charge is too low in stand alone gas mode. | Insert new batteries, then reset the error. | 10-SERIES |
| E14 | Battery packs have too little charge in standalone gas mode. | Insert new batteries, then reset the error. | 10-SERIES |
| E50 | Gas is locked after three ignition attempts. | Replace the empty gas cylinder and reset the error. | 10-SERIES, 10-SERIES |
| E50 | Gas lock occurred after three ignition attempts. | Replace the empty gas cylinder, then reset the error. | 10-SERIES |
| E51 | Gas lock is caused by an internal power module error. | Reset the error and contact service if it happens again. | 10-SERIES |
| E51 | Gas lock caused by an internal power module error. | Reset the error and contact customer service if it returns. | 10-SERIES |
| E51 | A gas lock results from an internal power module error. | Reset the error and contact customer service if it occurs again. | 10-SERIES |
| E52 | There is a ground contact fault at the gas valve. | Reset the error and contact service if it happens again. | 10-SERIES |
| E52 | Ground contact involving the gas valve. | Reset the error and contact customer service if it returns. | 10-SERIES |
| E52 | A ground contact fault affects the gas valve. | Reset the error and contact customer service if it occurs again. | 10-SERIES |
| E53 | There is a ground contact fault at the ignition electrode. | Reset the error and contact service if it happens again. | 10-SERIES |
| E53 | Ground contact involving the ignition electrode. | Reset the error and contact customer service if it returns. | 10-SERIES |
| E53 | A ground contact fault affects the ignition electrode. | Reset the error and contact customer service if it occurs again. | 10-SERIES |
| Err1 | An error has occurred. | CF11-O-AUS | |
| Err2 | An error has occurred. | CF11-O-AUS | |
| FL | Gas problem after unsuccessful ignition attempt. | Check the gas supply. | RM1350 |
| PE 4 | Previous shutdown resulted from low voltage on Line 1. | Portable / RV Refrigerator | |
| W01 | Temperature sensor in the refrigerator compartment is defective. | Contact an authorized customer service. | 10-SERIES |
| W05 | AC power is disconnected or voltage is below 190 volts. | Connect AC power or select gas or DC operation. | 10-SERIES |
| W06 | DC power is disconnected. | Connect DC power or select gas or AC operation. | 10-SERIES |
| W10 | The door has been open for more than two minutes. | Close the door. | 10-SERIES |
| W11 | DC supply voltage exceeds 16 volts. | Reduce the DC supply voltage. | 10-SERIES |