Key numbers from this manual

As printed in the manual, with metric and US units side by side. The typical range comes from all ice maker manuals on this site that print the same figure.

Door-open alarm after1 minuteFactory setting for the door ajar alarm0-600 secondsAdjustable door alarm activation timep. 10
Clearance above16" (40.64 cm) needs more space than mostAbove the refrigerator for ventilationTypical for ice makers: 0.3 to 6 in (0.8 to 15.2 cm)p. 4
Clearance behind2" (5 cm) needs less space than mostBehind the refrigerator for power cord clearanceTypical for ice makers: 3 to 6 in (7.6 to 15.2 cm)p. 4
Room temperature rangedoes not exceed 80 F (27 C)Indoor use; ambient relative humidity does not exceed 60% RHTypical for ice makers: 50 to 100 °F (10 to 38 °C)p. 4

Follett 01147842R03 questions

Answers taken from this manual. Each one links to the page it comes from.

What are the refrigerator's exterior width and depths?

The listed exterior measurements are:

MeasurementSize
Width59.75" (151.8 cm)
Depth30" (76.2 cm)
Depth with handles33.55" (85.2 cm)

Manual: page 3

How do I replace the door gasket?

Replace the gasket by removing the old seal, fitting the new one, and checking the door closure.

  1. Pull the existing gasket out of its mounting track.
  2. Clear all leftover gasket material from the mounting track.
  3. Line up the replacement gasket and press it firmly into the track.
  4. Open and close the door to check the seal, without pinching it against the refrigerator.

Manual: page 24

How do I force the ice maker into a defrost?

Set Manual Defrost to Yes to force the unit into a defrost.

Manual: page 17

Why does the unit sound after losing power?

The power alarm activates after power is lost for more than five minutes and sounds every 30 seconds during the failure. After power returns, an alarm box appears and the event log records the loss and restoration times.

Manual: page 10

Follett 01147842R03 compared with other brands

Ice Makers from other brands with the most of the same figures in their manuals. Values as printed in each manual.

Follett 01147842R03Scotsman MC1448MA-32AOther HZB-12True TCIM-422-FA1-A~*-#
Door-open alarm after1 minute···
Clearance above16" (40.64 cm)12-18 inches (45.7 cm)8 inches (20.3 cm)6" (152.4mm) (15.2 cm)
Clearance behind2" (5 cm)6" (15.2 cm)5 inches (12.7 cm)6" (152.4 mm)
Room temperature rangedoes not exceed 80 F (27 C)50oF. to 100oFbelow 90 °F (32 °C)35˚-100˚F (1.7˚-43.3C˚)

Similar Follett ice makers

Follett 01012715R07Service Manual44 pages
Follett 01441492R00Service Manual32 pages
Follett 00104109R09Service Manual16 pages
Follett 15CI114A-NW-**-**-**Installation & Operation Manual71 pages
Follett 25CI414A-LIInstallation & Operation Manual64 pages
Follett 12CI414AInstallation & Operation Manual60 pages
Follett D1810R-**Service Manual54 pages
Follett C1414AService Manual54 pages
All Follett ice makers →