Key numbers from this manual

As printed in the manual, with metric and US units side by side. The typical range comes from all ice maker manuals on this site that print the same figure.

Fridge factory setting38˚FFactory temperature-controller set point35 °F - 38 °F (2 °C, 3 °C)Factory preset cabinet temperaturep. 6 p. 7
DefrostautomaticREF Series undercounter refrigeratorsp. 7

Follett 00104109R09 questions

Answers taken from this manual. Each one links to the page it comes from.

What temperature does the factory setting use?

38˚F is the factory temperature-controller set point; the factory cabinet temperature is 35 °F - 38 °F.

Manual: page 6, page 7

How do I adjust the door for a proper gasket seal?
  1. Loosen the striker depth adjustment screw.
  2. Move the stop inward or outward, then tighten the screws.
  3. Test the latch operation.

Manual: page 8

How do I replace the refrigerator door gasket?
  1. Remove the old gasket from its mounting track.
  2. Clear any remaining gasket material from the mounting track.
  3. Align the replacement gasket with the track and press it firmly into place.
  4. Open and close the door to check the seal without pinching the gasket.
  5. Adjust the latch or striker if the door does not close properly.

Manual: page 8

How do I clear the recorded highest or lowest temperature?
  1. Press the button until HI or LOW appears.
  2. Press RESET to erase the recorded value.

Manual: page 12

What happens to the temperature alarm during a power failure?

The back-up battery keeps alarm monitoring active for temperatures outside the selected range; the dark display shows temperatures when you press RESET.

Manual: page 12

How do I set the temperature alarm limits?

After installation, allow 30 minutes for the alarm system to stabilize to ambient temperature.

  1. Press SET until CAL appears, then press SET again to show its value.
  2. Use the ADJUST arrow until calibration matches the refrigerator display.
  3. Press SET until HSP appears, press SET again, then adjust the desired high limit.
  4. Press SET until LSP appears, press SET again, then adjust the desired low limit.

Manual: page 12

Similar Follett ice makers

Follett 01012715R07Service Manual44 pages
Follett 01147842R03Service Manual36 pages
Follett 01441492R00Service Manual32 pages
Follett 15CI114A-NW-**-**-**Installation & Operation Manual71 pages
Follett 25CI414A-LIInstallation & Operation Manual64 pages
Follett 12CI414AInstallation & Operation Manual60 pages
Follett D1810R-**Service Manual54 pages
Follett C1414AService Manual54 pages
All Follett ice makers →