Key numbers from this manual
As printed in the manual, with metric and US units side by side. The typical range comes from all ice maker manuals on this site that print the same figure.
| Water supply pressure | 20 to 100 psi (138 to 690 kPa)water supply20 to 100 psi (138 to 690 kPa)Incoming water pressure | p. 15 p. 64 |
|---|---|---|
| Clearance above | 6" (152.4mm) (15.2 cm)TCIM/TI-5223" (76.2 mm)TCIM/TI-530Typical for ice makers: 0.3 to 6 in (0.8 to 15.2 cm) | p. 14 |
| Clearance at the sides | 6" (152.4 mm)TCIM/TI-4306" (152.4mm) (15.2 cm)TCIM/TI-530Typical for ice makers: 1 to 6 in (2.5 to 15.2 cm) | p. 14 |
| Clearance behind | 6" (152.4 mm)TCIM/TI-4306" (152.4mm) (15.2 cm)TCIM/TI-522Typical for ice makers: 3 to 6 in (7.6 to 15.2 cm) | p. 14 |
| Room temperature range | 35˚-100˚F (1.7˚-43.3C˚)Designed ambient temperature for proper operationTypical for ice makers: 50 to 100 °F (10 to 38 °C) | p. 64 |
True TCIM-422-FA1-A~*-# questions
Answers taken from this manual. Each one links to the page it comes from.
Should I use a water filter with this ice maker?
Yes. TRUE recommends a water filter because it can reduce particles affecting operation and equipment life; change it regularly for better ice quality and longer service.
Manual: page 15
What water pressure does this ice maker need?
20 psig (138 kPa) to 100 psig (689 kPa).
Other brands: Scotsman 20 to 80 psi (138 to 552 kPa) · Marvel 20 to 80 psi (138 to 552 kPa) · Whirlpool 30 to 120 psi (207 to 827 kPa) Compare all
Manual: page 15
What temperatures affect the ice maker's operating cycles?
These temperature conditions change the ice maker's cycle behavior.
| Condition | Temperature | Result |
|---|---|---|
| Evaporator outlet, T1 | 50˚F (10˚C) | Compressor operation ends |
| Ambient air, T2 | Greater than 104˚F (40˚C) | Pre-chill is required |
| T2, T3, or T4 | Less than 30˚F (-1.1˚C) | Drain is skipped at that point |
What should I check if the machine shows the E23 leakage alarm?
Check for water leaking near the evaporator cover, harvest flap or drain valve, because the sump level fell below its required difference.
Manual: page 66
How do I adjust the ice level sensor?
Press Menu to begin the ice level sensor adjustment.
- Press Menu in the screen’s upper-right corner.
- Press TOF in the Menu screen.
- Select the preset for your ice storage unit, or choose custom if none fits.
- For custom setup, enter each value with the number pad and press OK.
- Adjust only Empty Bin Distance (EBD), which True recommends changing.
How do I set up the water filter?
- Press Menu in the screen’s upper-right corner.
- Press Water Filter in the Menu screen.
- Select Standard, 14,000 gal (52,996 L), or Platinum, 35,000 gal (132,490 L).
- For a non-True filter, enter its capacity under CUSTOM.
Manual: page 44
How do I run a descaling cycle?
Remove all ice first; wear eye protection and rubber gloves, and never mix descaler with sanitizer.
- Open the front panel.
- From the home screen, press CLEAN, then press DESCALE.
- Choose PREVENTATIVE MAINT., STANDARD, or HEAVY based on maintenance needs.
- When the ice-making prompt appears, press NO.
- Wait through PRE-CLEANING, including FILL, PUMP, DRAIN, and HARVEST.
- When ADD CLEANER appears, pour 10 oz (296 mL) descaler between the evaporator and damper.
- Press OK after adding descaler.
- Wait until cleaning finishes and the home screen returns.
Can I cancel the cleaning sequence?
Yes, press cancel before adding cleaner or sanitizer and pressing OK; afterward, the sequence cannot be canceled.
Manual: page 52
Error codes in this manual
| Code | Meaning | What to do | |
|---|---|---|---|
| COM | Display is not communicating with the control board. | Check display and board connections; the unit may need a firmware update. | p. 67 |
| E1 | T1 probe is open or shorted. | Replace the probe. | p. 66 |
| E2 | T2 probe is open or shorted. | Replace the probe. | p. 66 |
| E3 | T3 probe is open or shorted. | Replace the probe. | p. 66 |
| E4 | T4 probe is open or shorted. | Replace the probe. | p. 66 |
| E6 | Discharge pressure exceeded 370 psi. | Clean the air filter and condenser coil; verify the condenser fan operates. | p. 66 |
| E7 | HP1 transducer signal is lost or indicates high pressure. | Check transducer wiring to the board; replace the transducer. | p. 66 |
| E8 | LP1 transducer signal is lost or indicates low pressure. | Check transducer wiring to the board; replace the transducer. | p. 66 |
| E9 | Water level sensor signal is lost. | Check sensor tubing and verify the board pressure chip has good contact. | p. 66 |
| E11 | T1 fell below minus 10 degrees during the first two freeze minutes. | Check probe resistance and location, pump operation, and whether the previous ice sheet fell. | p. 66 |
| E12 | Evaporator outlet temperature exceeded 113 degrees Fahrenheit. | Verify cold water supply and ambient temperatures; test the probe. | p. 66 |
| E13 | Evaporator outlet temperature fell below minus 20 degrees Fahrenheit. | Test the probe, outlet temperature, pump operation, and water supply. | p. 66 |
| E14 | Ambient temperature exceeded 130 degrees Fahrenheit. | Verify ambient temperature, test the probe, and verify condenser motor operation. | p. 66 |
| E15 | Ambient temperature fell below 33 degrees Fahrenheit. | Verify ambient temperature and test the probe. | p. 66 |
| E16 | Water trough temperature exceeded 113 degrees Fahrenheit. | Verify trough water temperature and test the probe. | p. 66 |
| E17 | Water trough temperature fell below 25 degrees Fahrenheit. | Verify trough water temperature and test the probe. | p. 66 |
| E18 | Incoming water temperature exceeded 124 degrees Fahrenheit. | Check water supply temperature and test the probe. | p. 66 |
| E19 | Incoming water temperature fell below 33 degrees Fahrenheit. | Check water supply temperature and test the probe. | p. 66 |
| E20 | HP1 head pressure exceeded 320 to 360 psi, depending on model. | Clean the air filter and condenser coil; verify proper condenser fan operation. | p. 66 |
| E22 | Freeze cycle exceeded 40 minutes. | Verify compressor operation and check high and low side pressures. | p. 66 |
| E23 | Sump water level fell below the freeze cycle differential. | Check for leaks near the evaporator cover, harvest flap, and drain valve. | p. 66 |
| E24 | Sump tank did not fill within 30 minutes. | Verify water supply; check the incoming filter and inlet valve. | p. 66 |
| E25 | Sump water did not drain to the proper level within four minutes. | Check drain valve voltage, clear and vent the drain, and check the sump drain. | p. 67 |
| E26 | Bin switch failed to open during three harvests, or startup temperature stayed too low. | Check stuck switch contacts, evaporator freezing, and ice sheet pattern. | p. 67 |
| E27 | Water level fell below the harvest initiation level during the first five minutes. | Check excessive splashing, the water curtain, harvest flap, and leaking drain valve. | p. 67 |
| E28 | During startup, water level did not fall below 43 millimeters within 60 seconds. | Check pump voltage and verify the inlet valve shuts off. | p. 67 |
| E29 | Sump tank did not fill within three minutes. | Check the water filter, incoming pressure, inlet valve, and drain valve. | p. 67 |
| E30 | UV Biozone system failure. | Check the UV menu for low current, high current, or exceeded lamp time. | p. 67 |
| E31 | High side pressure exceeded 165 psi during harvest. | Follow the No Harvest or Frozen In flow chart. | p. 67 |
| E32 | Low side pressure fell below 10 psi during freezing. | Check cycle times, pressures, ice pattern, leaks, and restrictions. | p. 67 |
| E33 | Secondary high side transducer failed. | Check transducer wiring to the control board; replace the transducer. | p. 67 |
| E34 | Secondary low side transducer failed. | Check transducer wiring to the control board; replace the transducer. | p. 67 |
| H₂O | Sump tank did not fill within three minutes. | Check the water filter, incoming pressure, inlet valve, and drain valve. | p. 67 |
True TCIM-422-FA1-A~*-# compared with other brands
Ice Makers from other brands with the most of the same figures in their manuals. Values as printed in each manual.
| True TCIM-422-FA1-A~*-# | Scotsman HID207 | Follett 25CI414A-LI | EdgeStar IB450SS | |
|---|---|---|---|---|
| Water supply pressure | 20 to 100 psi (138 to 690 kPa) | 19 to 80 psi (130 to 552 kPa) | 10/0.7 Min. to 70/5 Max | 7 to 116 psi (50 to 800 kPa) |
| Clearance above | 6" (152.4mm) (15.2 cm) | 2 inches or 5 cm above, 10” or 25 cm more | 4" (10.2 cm) | 1” |
| Clearance at the sides | 6" (152.4 mm) | 6 inches or 15 cm at each side | 3" (7.7 cm) | 1/2” |
| Clearance behind | 6" (152.4 mm) | 6 inches or 15 cm at the back | 3" (7.7 cm) | more than 1/2” |
| Room temperature range | 35˚-100˚F (1.7˚-43.3C˚) | Minimum: 50oF. or 10oC.; Maximum: 100oF. or 38oC | 50 F/10 C Min. to 100 F/38 C Max | between 50 °F and 100 °F (10 °C, 38 °C) |
Similar True ice makers
| True TCIM-422-FA1-A~*-#Model family TCIM422FA1A | Installation & Operation Manual | 96 pages |
|---|