Key numbers from this manual

As printed in the manual, with metric and US units side by side. The typical range comes from all refrigerator manuals on this site that print the same figure.

Fridge factory settingCut-Out at 35ºF and Cut-In 39ºF colder than mostStandard temperature control when leaving the factoryTypical for refrigerators: 37 to 39 °F (3 to 4 °C)p. 6
Time to cool downThree to four hoursAfter equipment starts, before storage temperature reaches condensing-unit cyclingan hourbefore reloading after cleaning the machine compartmentTypical for refrigerators: 4 to 24 hoursp. 6 p. 8
Clearance behind3 inches (7.6 cm) needs more space than mostMinimum clearance behind the cabinetTypical for refrigerators: 1.5 to 3 in (3.8 to 7.6 cm)p. 5
Room temperature range75oFOperating location ambient temperatureTypical for refrigerators: 50 to 100 °F (10 to 38 °C)p. 5

Howard-McCray Refrigerator questions

Answers taken from this manual. Each one links to the page it comes from.

What temperature settings and alarm limits does the cabinet use?

35ºF Cut-Out and 39ºF Cut-In are standard; alarm limits are 45ºF high and 32ºF low.

SettingTemperature
Cut-In39ºF
Cut-Out35ºF
Alarm High Limit45ºF
Alarm Low Limit32ºF

Manual: page 7

What temperatures and delay are programmed for the alarm?

The controller sounds the alarm at these limits and after this delay.

Alarm settingValueTiming
High temperature45ºFAfter limit is reached
Low temperature32ºFAfter limit is reached
Alarm delay+10 MinutesAfter limit is reached

Manual: page 7

What should I do if the alarm sounds during pull-down?

Press the SET button on the controller to restart the unit until it reaches its programmed temperature.

Manual: page 7

What should I do when the display shows CA?

The required response depends on the digital-input configuration.

  • Serious external alarm, i1F=bAL. Deactivate the digital input; all outputs remain off until then.
  • Pressure-switch alarm, i1F=PAL. Switch the instrument off and on after the nPS activation limit is reached.

Manual: page 16

Error codes in this manual

CodeMeaningWhat to do
CASerious external or pressure switch alarm.Deactivate the input; for pressure alarms, switch the instrument off and on.p. 16
dADoor open alarm.Close the door or disable the external digital input.p. 16
EAExternal alarm.Deactivate the digital input to stop the alarm.p. 16
ErrProgramming failed.Press the upload key again, or remove the Hot Key to cancel.p. 16
HAMaximum temperature alarm.The alarm stops automatically when temperature returns to normal.p. 16
HA2Condenser high temperature alarm.The alarm stops automatically when temperature returns to normal.p. 16
LAMinimum temperature alarm.The alarm stops automatically when temperature returns to normal.p. 16
LA2Condenser low temperature alarm.The alarm stops automatically when temperature returns to normal.p. 16
P1Room thermostat probe failure.Check probe connections before replacing the probe.p. 16
P2Evaporator probe failure.Check probe connections before replacing the probe.p. 16
P3Third probe failure.Check probe connections before replacing the probe.p. 16
P4Fourth probe failure.Check probe connections before replacing the probe.p. 16
All Howard-McCray error codes →

Howard-McCray Refrigerator compared with other brands

Refrigerators from other brands with the most of the same figures in their manuals. Values as printed in each manual.

Howard-McCray RefrigeratorSummit ASDR1524KitchenAid RefrigeratorAvanti RA7306WT
Fridge factory settingCut-Out at 35ºF and Cut-In 39ºF38 °F/3 °C37 °F (3 °C)“7” or the max-position
Clearance behind3 inches (7.6 cm)5” (127mm)1" (2.54 cm)5”
Room temperature range75oFabove 44 °F (7 °C) and below 90 °F (32 °C)55 °F (13 °C) to 110 °F (43 °C)above 60 °F (16 C) and below 90 °F (32 °C)