As printed in the manual, with metric and US units side by side. The typical range comes from all refrigerator manuals on this site that print the same figure.
| Door-open alarm after | 5 minutesdoor left openTypical for refrigerators: 1 to 5 minutes | p. 38 |
|---|---|---|
| Clearance above | no additional air spaceBuilt-in installationnonebuilt-in installationTypical for refrigerators: 1 to 3.9 in (2.5 to 9.9 cm) | p. 8 |
| Clearance at the sides | no additional air spaceBuilt-in installationnonebuilt-in installationTypical for refrigerators: 0.7 to 3.1 in (1.8 to 7.9 cm) | p. 8 |
| Clearance behind | no additional air spaceBuilt-in installation; clearance is required for an electrical connectionTypical for refrigerators: 1.5 to 3 in (3.8 to 7.6 cm) | p. 8 |
| Space to open the doors | 1/4" (6 mm)side-by-side installation, between units | p. 10 |
| Defrost | automatic | p. 24 |
| Room temperature range | 50 °F (10 °C) and 100 °F (38 °C)Operating environmentTypical for refrigerators: 50 to 100 °F (10 to 38 °C) | p. 6 |
U-Line U-ADA24RGLS-13B questions
Answers taken from this manual. Each one links to the page it comes from.
How do I check the actual product temperature inside the refrigerator?
- Partially fill a plastic, nonbreakable bottle with water.
- Insert an accurate thermometer.
- Tighten the bottle cap securely.
- Place the bottle in the desired area for 24 hours.
- Avoid opening the unit during the testing period.
- After 24 hours, check the water temperature and adjust the control in a small increment.
Manual: page 25
What temperature adjustment should I make when products freeze or stay warm?
Use a warmer set point for freezing products, or a cooler set point when products are not cold enough.
- Products freezing: Keep products away from the rear wall and use a warmer set point.
- Products not cold enough: Adjust the temperature to a cooler set point.
Manual: page 25
Why is frost forming inside my refrigerator?
- Normal rear-wall frost. It should melt during each off cycle.
- Frost buildup of 1/4" or more. Manually defrost the unit.
- Poor door sealing. Check that the door closes and seals properly.
- High ambient temperature or humidity. Check the installation conditions.
Manual: page 24
Why is condensation forming on the outside of my refrigerator?
Excessive humidity causes external condensation. Moisture dissipates as humidity levels decrease.
Manual: page 24
Why did the compressor stop after repeated control tests?
Compressor overload can deactivate it after frequent relay toggling. Leave at least 5 minutes of off time between relay cycles.
Manual: page 38
What room temperature range does this refrigerator support?
50 °F (10 °C) to 100 °F (38 °C).
Manual: page 6
How much space is needed between two units installed side by side?
Leave 1/4" (6 mm) between the units for unobstructed door swing.
Manual: page 10
Why does the refrigerator show an error and sound an alarm when the door stays open?
After more than 5 minutes open, the door switch triggers an error code and an audible warning.
Manual: page 38
Error codes in this manual
| Code | Meaning | What to do | |
|---|---|---|---|
| E1 | Thermistor 1 is open. | p. 38 | |
| E2 | Thermistor 2 is open. | p. 38 | |
| E3 | Thermistor 3 is open. | p. 38 | |
| E4 | Thermistor 4 is open. | p. 38 | |
| E5 | Thermistor 1 is shorted. | p. 38 | |
| E6 | Thermistor 2 is shorted. | p. 38 | |
| E7 | Thermistor 3 is shorted. | p. 38 | |
| E8 | Thermistor 4 is shorted. | p. 38 | |
| E9 | Door 1 is open. | p. 38 | |
| E10 | Door 2 is open. | p. 38 | |
| E11 | Water level in tray or reservoir is high. | p. 38 | |
| E12 | Water level is low. | p. 38 | |
| E13 | Auger error. | p. 38 | |
| P1 | Pump circuit is open. | p. 38 |
U-Line U-ADA24RGLS-13B compared with other brands
Refrigerators from other brands with the most of the same figures in their manuals. Values as printed in each manual.
| U-Line U-ADA24RGLS-13B | Whirlpool WRB3504S | KitchenAid REFRIGERADOR.......27 | Hisense HQD20 | |
|---|---|---|---|---|
| Door-open alarm after | 5 minutes | 2 minutes | 5 minutes | 2 minutes |
| Space to open the doors | 1/4" (6 mm) | 350mm | 2" (5.08 cm) on each side | 4" (10 cm) minimum |
| Room temperature range | 50 °F (10 °C) and 100 °F (38 °C) | above 10 °C (50 °F) | 55 °F (13 °C) to 110 °F (43 °C) | 55 °F (13 °C) to 110 °F (43 °C) |
Similar U-Line refrigerators
| U-Line UACR015-SS01A | Service Manual | 44 pages |
|---|---|---|
| U-Line U-3036RRINT-00B | Service Manual | 72 pages |
| U-Line URNP115-IS01A | Service Manual | 33 pages |
| U-Line ADA24R | Operating Instructions | 63 pages |
| U-Line 3018CLR | Service Manual | 63 pages |
| U-Line 1215WC | Service Manual | 59 pages |