As printed in the manual, with metric and US units side by side. The typical range comes from all refrigerator manuals on this site that print the same figure.
| Fridge adjustment range | 35 to 46 °F (2 °C to 8 °C)Fridge modeTypical for refrigerators: 36 to 46 °F (2 to 8 °C) | p. 12 |
|---|---|---|
| Freezer factory setting | 0 °F (-18 °C)Freezer modeTypical for refrigerators: 0 °F (-18 °C) | p. 12 |
| Freezer adjustment range | 10 °F to -11 °F (-12 °C to -24 °CFreezer modeTypical for refrigerators: -9 to 5 °F (-23 to -15 °C) | p. 12 |
| Wait before use | approximately two hoursbefore connecting the freezer to power after transportation | p. 7 |
| Time to cool down | Four hoursAfter the freezer has been disconnected, before adding foodTypical for refrigerators: 4 to 24 hours | p. 17 |
| Clearance above | 11.8 inches (30 cm) needs more space than mostbetween the freezer top and ceilingTypical for refrigerators: 1 to 3.9 in (2.5 to 9.9 cm) | p. 8 |
| Clearance at the sides | 7.9 inches (20 cm) needs more space than mostbetween the freezer sides and wallsTypical for refrigerators: 0.7 to 3.1 in (1.8 to 7.9 cm) | p. 8 |
| Clearance behind | 3.9 inches (10 cm) needs more space than mostbetween the freezer back and wallTypical for refrigerators: 1.5 to 3 in (3.8 to 7.6 cm) | p. 8 |
| Control lock | YesThe control panel can be locked | p. 12 |
Models in this manual
4 models with ENERGY STAR certified data. Models with the same figures share a row.
| Models | Type | Capacity | Energy use | Ice | Height × width |
|---|---|---|---|---|---|
| NS-UZ14SS0, NS-UZ14SS0-C, NS-UZ14WH0, NS-UZ14WH0-C | Upright Freezer | 13.8 ft³391 L | 394 kWh/yr10% below US standardabout the same as the median of 137 similar certified models (394 kWh/yr) | None |
Insignia NS-UZ14SS0 questions
Answers taken from this manual. Each one links to the page it comes from.
How long should I wait after reconnecting the freezer before adding food?
Four hours are required for the freezer to cool completely before adding food.
Manual: page 17
Why does my freezer not run?
- The freezer is unplugged. Push the plug completely into the outlet.
- The fuse is blown or the circuit breaker tripped. Replace the fuse or reset the breaker.
- A power failure occurred. Wait until power is restored.
Manual: page 16
Why is food in my freezer not cold?
- The door opened often or was not closed properly. Check that the door closes properly.
- A large amount of food was added. Allow time for the new food to cool.
- The freezer was disconnected recently. Before adding food, allow four hours for complete cooling.
- The thermostat is set too warm. Set it to a colder setting.
Other brands: LG 3 or 4 hours · Midea 4 hours · Samsung 2-3 hours Compare all
Manual: page 17
What do the freezer’s beeps mean?
The beep identifies a temperature limit or confirms a control-panel lock action.
| Action or condition | Meaning |
|---|---|
| Temperature reaches MAX or MIN | A beep sounds |
| Hold Lock to lock | Panel beeps |
| Hold Lock to unlock | Panel beeps |
Manual: page 12
How do I switch between freezer and refrigerator modes?
Prepare the control panel, then change the mode with Freezer/Fridge.
- Hold Lock for three seconds to prepare the control panel.
- Hold Freezer/Fridge for three seconds.
- Confirm the panel beeps and the indicator changes to the new mode.
Manual: page 13
What do E2, E5, and E7 mean on the display?
Each code signals a sensor fault; call for service when one appears.
| Code | Meaning | Action |
|---|---|---|
| E2 | Temperature sensor fault | Call for service |
| E5 | Defrost sensor fault | Call for service |
| E7 | Ambient temperature sensor fault | Call for service |
Manual: page 16
Error codes in this manual
| Code | Meaning | What to do | |
|---|---|---|---|
| E2 | Temperature sensor fault | Call for service. | p. 16 |
| E5 | Defrost sensor fault | Call for service. | p. 16 |
| E7 | Ambient temperature sensor fault | Call for service. | p. 16 |
Insignia NS-UZ14SS0 compared with other brands
Refrigerators from other brands with the most of the same figures in their manuals. Values as printed in each manual.
| Insignia NS-UZ14SS0 | Summit ASDR1524 | KitchenAid Refrigerator | Maytag Refrigerator | |
|---|---|---|---|---|
| Fridge adjustment range | 35 to 46 °F (2 °C to 8 °C) | 36 °F/2 °C to 43 °F/6 °C | 33 °F to 42 °F (0 °C to 6 °C) | 33 °F to 45 °F (0 °C to 7 °C) |
| Freezer factory setting | 0 °F (-18 °C) | 0 °F/-18 °C | 0 °F (-18 °C) | 0 °F (-18 °C) |
| Freezer adjustment range | 10 °F to -11 °F (-12 °C to -24 °C | -11 °F/-24 °C to 11 °F/-12 °C | -9 °F to 5 °F (-23 °C to -15 °C) | -5 °F to 5 °F (-21 °C to -15 °C) |
| Clearance above | 11.8 inches (30 cm) | 4” (102mm) | 1/2" (1.27 cm) | ¹⁄₂" (1.25 cm) |
| Clearance at the sides | 7.9 inches (20 cm) | 5” (127mm) | 1/2" (1.27 cm) | ¹⁄₂" (1.25 cm) |
| Clearance behind | 3.9 inches (10 cm) | 5” (127mm) | 1" (2.54 cm) | 1" (2.54 cm) |
Similar upright freezer models from other brands
Same layout, capacity within 1.5 ft³ (42 L) of this one. Figures: ENERGY STAR.
| Model | Capacity | Energy use | Ice | Counter depth |
|---|---|---|---|---|
| Midea MRU14F5 | 13.8 ft³391 L | 394 kWh/yr | None | No |
| Danby DUF140E1WDD | 13.8 ft³391 L | 394 kWh/yr | None | No |
| Forno FFFFD1933-28LS | 13.8 ft³391 L | 394 kWh/yr | None | No |
| Element EUF14CDB | 13.8 ft³391 L | 394 kWh/yr | None | No |
| Koolatron KKUF14-W | 13.8 ft³391 L | 394 kWh/yr | None | No |
| Signature Kitchen Suite SKSCF2401 | 13.9 ft³394 L | 500 kWh/yr | Ice maker, door dispenser | No |