Key numbers from this manual

As printed in the manual, with metric and US units side by side. The typical range comes from all refrigerator manuals on this site that print the same figure.

Clearance aboveno additional air spacebuilt-in installationTypical for refrigerators: 1 to 3.9 in (2.5 to 9.9 cm)p. 8
Clearance at the sidesno additional air spacebuilt-in installationTypical for refrigerators: 0.7 to 3.1 in (1.8 to 7.9 cm)p. 8
Clearance behindno additional air spacebuilt-in installation, with clearance required for an electrical connectionTypical for refrigerators: 1.5 to 3 in (3.8 to 7.6 cm)p. 8
Space to open the doors1/4" (6 mm)between side-by-side unitsp. 10
DefrostAutomatic Defrostp. 27

U-Line ADA24R questions

Answers taken from this manual. Each one links to the page it comes from.

How do I check the actual temperature inside?

Use a capped water bottle with an accurate thermometer, then leave it undisturbed for 24 hours.

  1. Partially fill a plastic, nonbreakable bottle with water.
  2. Insert an accurate thermometer and tighten the bottle cap securely.
  3. Place the bottle in the desired area for 24 hours.
  4. Avoid opening the unit during the test.
  5. After 24 hours, check the water temperature.
  6. If needed, adjust the temperature control in a small increment.

Manual: page 28

Why is the refrigerator not cold enough?
  • Temperature setting. Adjust to a cooler set point.
  • Warm surroundings or sunlight. Move it away from excessive ambient temperatures or direct sunlight.
  • Door seal or frequent openings. Check that the door closes and seals properly.
  • Blocked airflow or dirty condenser coil. Clear the front grille and clean the condenser coil.
  • Interior light left on. Check that the light has not remained on too long.

Manual: page 28

Why is condensation forming on the outside?

Excessive humidity causes external condensation; moisture dissipates as humidity decreases.

Manual: page 27

Why isn't the ice maker harvesting?

A raised bin arm prevents harvesting; lower the bin arm to permit the ice maker motor to run.

Manual: page 44

What happens during the ice maker's water-fill cycle?

At approximately 10:00, the ejector activates the water-fill switch, powering the water valve and filling the mold.

Manual: page 46

What clearances does a built-in ADA24R installation need?

No additional air space is needed at the top, sides, or rear, but the front grille must remain unobstructed and the rear needs electrical clearance. Do not install the unit behind a closed cabinet door.

Manual: page 8

How much space should separate two units installed side by side?

Leave 1/4" (6 mm) between the units for unobstructed door swing.

Manual: page 10

How does the error log work?

The stored errors scroll through the display once; repeat the viewing if needed, then clear the log after checking it.

Manual: page 54

Error codes in this manual

CodeMeaningWhat to do
E1Thermistor 1 is open.p. 55
E2Thermistor 2 is open.p. 55
E3Thermistor 3 is open.p. 55
E4Thermistor 4 is open.p. 55
E5Thermistor 1 is shorted.p. 55
E6Thermistor 2 is shorted.p. 55
E7Thermistor 3 is shorted.p. 55
E8Thermistor 4 is shorted.p. 55
E9The door is open.p. 55
PiThe pump circuit is open.p. 55
All U-Line error codes →

Similar U-Line refrigerators

U-Line U-3036RRINT-00BService Manual72 pages
U-Line 3018CLRService Manual63 pages
U-Line 1215WCService Manual59 pages
U-Line U-ADA24RGLS-13BService Manual44 pages
U-Line UACR015-SS01AService Manual44 pages
U-Line URNP115-IS01AService Manual33 pages
All U-Line refrigerators →