Key numbers from this manual

As printed in the manual, with metric and US units side by side. The typical range comes from all commercial refrigerator manuals on this site that print the same figure.

Recommended fridge temperature32 °F - 38 °F (1 °C - 3.3 °C)Beer dispensingTypical for commercial refrigeration: 32 to 40 °F (0 to 4 °C)p. 6
Fridge adjustment range31 °F to 41 °F (-0.5 °C to 5 °C)Thermostat adjustment rangeTypical for commercial refrigeration: 34 to 45 °F (1 to 7 °C)p. 6
Wait before useapproximately 24 hoursBefore connecting after transportationp. 5
Time to cool down3 to 4 hoursAfter plugging in, before installing a kegTypical for commercial refrigeration: 1 to 24 hoursp. 5
Clearance at the sidesat least 3”Between surrounding walls and the cabinet wallTypical for commercial refrigeration: 0 to 4 in (0 to 10.2 cm)p. 5

Kegco Commercial Refrigerator questions

Answers taken from this manual. Each one links to the page it comes from.

How do I set the kegerator temperature?

Use the coldest setting for initial cooling, then select the desired range.

  1. Set the temperature control knob to 7 for the coldest position.
  2. Let the unit run for 48 hours.
  3. Adjust the thermostat to the desired temperature range.

Manual: page 6

What temperature is best for dispensing beer?

32 °F to 38 °F (1 °C to 3.3 °C) is best for dispensing beer; temperatures outside that range may cause foam issues.

Other brands: Other +4 C · Liebherr just above 32 °F (0 °C) · True #4 or #5 Compare all

Manual: page 6

Does condensation require plumbing?

No. Condensate drains into a pan beneath the cabinet, and the drainage systems do not require plumbing.

Manual: page 7

What should I do with the waste product drain jar?

Empty and clean the plastic waste product jar periodically.

Manual: page 7

How much clearance does the kegerator need around the cabinet?

At least 3” is required between surrounding walls and the cabinet wall; the front must be completely unobstructed for ventilation.

Manual: page 4, page 5

Where should I place the kegerator during installation?

Place it on a flat, solid floor strong enough to support a full load, away from sunlight, heat sources, and damp areas.

Manual: page 5

How do I turn the kegerator off?

Turn the temperature control knob to OFF.

Manual: page 6

Kegco Commercial Refrigerator compared with other brands

Commercial Refrigeration from other brands with the most of the same figures in their manuals. Values as printed in each manual.

Kegco Commercial RefrigeratorPolar CU636Gram KS441862Atosa Commercial Refrigerator
Recommended fridge temperature32 °F - 38 °F (1 °C - 3.3 °C)6 °C (43 °F)+4 °C (39 °F)·
Fridge adjustment range31 °F to 41 °F (-0.5 °C to 5 °C)2-10 °C (14 °F)0-8 °C (18 °F)33℉ - 45℉
Wait before useabout 24 hoursabout 12 hours3 hoursat least 2 hours
Time to cool down3 to 4 hours··24 hours
Clearance at the sidesat least 3”2.5cm2 cm (0.8 in)at least 6 inches (15.2 cm)