Key numbers from this manual
As printed in the manual, with metric and US units side by side. The typical range comes from all commercial refrigerator manuals on this site that print the same figure.
| Fridge factory setting | 34 °F to 38 °F (1 °C, 3 °C) colder than mostRefrigerator factory settingTypical for commercial refrigeration: 35 to 38 °F (2 to 3 °C) | p. 7 |
|---|---|---|
| Fridge adjustment range | 34 °F to 38 °F (1 °C, 3 °C)refrigerator factory temperature rangeTypical for commercial refrigeration: 34 to 45 °F (1 to 7 °C) | p. 7 |
| Freezer factory setting | -7°Fto -1 °F (-22 °C, -18 °C)Freezer factory settingTypical for commercial refrigeration: -4 to 0 °F (-20 to -18 °C) | p. 7 |
| Freezer adjustment range | -7°Fto -1 °F (-22 °C, -18 °C)freezer factory temperature rangeTypical for commercial refrigeration: -8 to 3 °F (-22 to -16 °C) | p. 7 |
| Wait before use | at least 24 hoursAfter laying the unit on its side or back | p. 6 |
| Clearance above | 12" (30.5 cm)Minimum clear space above the unitTypical for commercial refrigeration: 0 to 12 in (0 to 30.5 cm) | p. 6 |
| Clearance at the sides | 2" (5.1 cm)Minimum distance from any wallTypical for commercial refrigeration: 0 to 4 in (0 to 10.2 cm) | p. 6 |
| Clearance behind | 2" (5.1 cm)Minimum distance from any wall; install the supplied bumper on the backmore than six inches (6”/20 cm)between the cabinet and wall; do not install the back flushTypical for commercial refrigeration: 1 to 4 in (2.5 to 10.2 cm) | p. 6 p. 3 |
| Room temperature range | below 90 °F (32 °C)Controlled environmentTypical for commercial refrigeration: 60 to 100 °F (16 to 38 °C) | p. 6 |
Other Commercial Refrigerator questions
Answers taken from this manual. Each one links to the page it comes from.
What factory temperature ranges apply to the refrigerator and freezer?
The factory ranges differ by compartment.
| Compartment | Factory range |
|---|---|
| Refrigerator | 34 °F to 38 °F |
| Freezer | -7°Fto -1 °F |
Other brands: Liebherr b1 to b9 · Summit 36 °F/2 °C to 43 °F/6 °C · True #1 to #9 Compare all
Manual: page 7
How do I view the temperature setpoint?
Use the SET key to display the target temperature.
- Push and immediately release SET; the setpoint appears.
- Push SET again, or wait 5 seconds, to return to the sensor temperature.
Manual: page 8
How do I clean the door gasket?
Use warm soapy water. Avoid full-strength cleaners and sharp tools, which can damage the gasket or tear its bellows.
Manual: page 10
How do I replace a damaged door gasket?
The gasket can be replaced without tools or an authorized service technician.
- Pull the old gasket from the groove in the door.
- Press the replacement gasket into the door groove.
Manual: page 10
How do I reset a recorded alarm?
Reset the recorded alarm after its signal appears.
- Hold SET until rst appears.
- Press SET again; the normal temperature display returns.
Manual: page 8
How do I start a manual defrost?
How do I level this cabinet?
Use a level to check the cabinet from front to back and side to side.
- With legs: adjust the bullet feet until the cabinet is level.
- With casters: make no adjustments; place the unit on a level floor.
Manual: page 6
How do I stabilize the cabinet during use?
Lock the front wheels before using the cabinet.
- Place the cabinet on a level floor.
- Lock the front wheels.
Manual: page 6
How much space should I leave behind the cabinet?
More than six inches (6”/20 cm) from the cabinet to the wall is required; do not install the back flush.
Manual: page 3
Why does the unit stop working in a hot, humid room?
At 95 °F ambient temperature or higher, with humidity above 70%, the unit may not operate properly. Warranty coverage excludes this condition and excessive frost or temperature problems outside these conditions.
Manual: page 3
Other Commercial Refrigerator compared with other brands
Commercial Refrigeration from other brands with the most of the same figures in their manuals. Values as printed in each manual.
| Other Commercial Refrigerator | Gram Commercial Refrigerator | Summit FF64BCSS | Hoshizaki Commercial Refrigerator | |
|---|---|---|---|---|
| Fridge factory setting | 34 °F to 38 °F (1 °C, 3 °C) | 5 °C (41 °F) | 38 °F/3 °C | 36 °F (2 °C) |
| Fridge adjustment range | 34 °F to 38 °F (1 °C, 3 °C) | 2 to 12 °C (36 to 54 °F) | 36 °F/2 °C to 43 °F/6 °C | 36 °F and 50 °F (2 °C and 10 °C) |
| Freezer factory setting | -7°Fto -1 °F (-22 °C, -18 °C) | -18 °C (0 °F) | 0 °F/-18 °C | -3 °F (-19 °C) |
| Freezer adjustment range | -7°Fto -1 °F (-22 °C, -18 °C) | -10 to -22 °C (14 to -8 °F) | -11 °F/-24 °C to 11 °F/-12 °C | -10 °F and 25 °F (-23 °C and -4 °C) |
| Wait before use | at least 24 hours | at least 2 hours | · | · |
| Clearance above | 12" (30.5 cm) | 250 mm (9.8 in) | 4“(102mm) | 10" (25 cm) |
| Clearance at the sides | 2" (5.1 cm) | 20 mm (0.8 in) | 5” (127mm) | 4" (11 cm) |
Similar Other commercial refrigeration
| Other Commercial Refrigeration User Manual | User Manual | 63 pages |
|---|---|---|
| Other 9301F-290 | Operating Instructions | 52 pages |
| Other Commercial Refrigeration Operating Instructions | Operating Instructions | 11 pages |
| Other Commercial Refrigeration User Manual | User Manual | 10 pages |
| Other LSC-235W | User Manual | 9 pages |
| Other SCL260 | User Manual | 6 pages |