Key numbers from this manual
As printed in the manual, with metric and US units side by side. The typical range comes from all commercial refrigerator manuals on this site that print the same figure.
| Fridge factory setting | b5Default temperature settingTypical for commercial refrigeration: 35 to 38 °F (2 to 3 °C) | p. 8 |
|---|---|---|
| Recommended fridge temperature | just above 32 °F (0 °C)Automatic temperature settingTypical for commercial refrigeration: 32 to 40 °F (0 to 4 °C) | p. 8 |
| Fridge adjustment range | b1 to b9b1 is coldest and b9 is warmestTypical for commercial refrigeration: 34 to 45 °F (1 to 7 °C) | p. 8 |
| Defrost | NoFrost | p. 9 |
Liebherr Commercial Refrigerator questions
Answers taken from this manual. Each one links to the page it comes from.
What do the temperature settings mean?
The appliance uses settings from b1, coldest, to b9, warmest, with b5 as the default.
| Setting | Meaning |
|---|---|
| b1 | Coldest |
| b5 | Default |
| b9 | Warmest |
Manual: page 8
How do I adjust the BioFresh temperature?
Use the adjustment buttons to select a setting from b1 through b9.
- Press the Up adjustment button or Down adjustment button until the temperature flashes.
- Release the button when the temperature flashes in the display.
- Press briefly for gradual changes, or hold the button for continuous changes.
- Wait about 5 seconds after the last press for the actual temperature to display.
Manual: page 8
Does this appliance need manual defrosting?
Why are the outside surfaces hot?
The refrigerant circuit's heat prevents condensate from forming, and this is normal.
Manual: page 12
Why isn't my refrigerator running?
- The appliance is switched off. Switch on the appliance.
- The power plug is loose. Check the power plug in the wall socket.
- The wall-socket fuse is faulty. Check the fuse.
- Power failure. Keep it closed; use dry ice or an alternate freezer if prolonged. Do not re-freeze defrosted food.
Manual: page 11
Can I replace the door seal myself?
Yes, the door seal is interchangeable and can be replaced without special tools; contact customer service.
Manual: page 13
Why is the appliance icing up or building condensation?
The door seal may have slipped out of its groove. Check that the door seal is well placed in the groove.
Manual: page 13
What should I avoid if ice appears during defrosting?
Do not use these methods or tools for defrosting:
- Mechanical devices or other methods not recommended by the manufacturer.
- Electrical heating equipment, steam cleaning, naked flames, or defrosting sprays.
- Sharp objects for removing ice.
- Anything that could damage refrigerant-circuit pipes.
Manual: page 9
Liebherr Commercial Refrigerator compared with other brands
Commercial Refrigeration from other brands with the most of the same figures in their manuals. Values as printed in each manual.
| Liebherr Commercial Refrigerator | True TMC-34-DS-HC | U-Line UCRE552-SS61A | Gram Commercial Refrigerator | |
|---|---|---|---|---|
| Fridge factory setting | b5 | 35 °F (1.6 °C) | 2 °C (36 °F) | 5 °C (41 °F) |
| Recommended fridge temperature | just above 32 °F (0 °C) | #4 or #5 | 0 °C to 2 °C (32 °F to 36 °F) | 4, 5, 6 °C (43 °F) |
| Fridge adjustment range | b1 to b9 | #1 to #9 | -2 °C (-28 °F) to 8 °C (46 °F) | 2 to 8 °C (36 to 46 °F) |