Key numbers from this manual
As printed in the manual, with metric and US units side by side. The typical range comes from all commercial refrigerator manuals on this site that print the same figure.
| Fridge adjustment range | 34 °F to 38 °F (1 °C, 3 °C)Refrigerators, factory settingTypical for commercial refrigeration: 34 to 45 °F (1 to 7 °C) | p. 3 |
|---|---|---|
| Freezer adjustment range | -7 to -3 °F (-22 to -19 °C)Freezers, factory settingTypical for commercial refrigeration: -8 to 3 °F (-22 to -16 °C) | p. 3 |
| Wait before use | at least 24 hoursAfter laying the unit on its side or back | p. 3 |
| Clearance above | 12”Clear space above the unitTypical for commercial refrigeration: 0 to 12 in (0 to 30.5 cm) | p. 3 |
Kelvinator KCHRI27R1DFE questions
Answers taken from this manual. Each one links to the page it comes from.
What can I use to clean the stainless steel?
Use soft cloths or plastic scouring pads with alkaline-based or non-chloride-based cleaners.
Manual: page 6
What should I do after using a chloride-containing cleaner?
Rinse and dry the stainless steel thoroughly after using a chloride-containing cleaner.
Manual: page 6
How much clearance does this commercial refrigerator need around it?
Leave at least 2” from any wall and 12” of clear space above the unit.
Manual: page 3
How should I load the cabinet to maintain airflow?
Do not pack the cabinet so tightly that air cannot circulate. Keep the top-rear air path open to prevent coil freeze-ups, temperature loss, or drain-pan overflow.
Manual: page 3
How do I start a manual defrost?
Press and hold the DEF key for more than 2 seconds to start a manual defrost.
Manual: page 4
How often should I clean the condenser coil?
Every 90 days, or every 30 days if heavy debris, dust, or grease builds up sooner.
Manual: page 5
How do I view and reset a recorded alarm?
- Use the controller keys to display the alarm signals.
- Hold SET until rst appears.
- Push SET again; rst blinks, then the normal temperature returns.
Manual: page 5
Kelvinator KCHRI27R1DFE compared with other brands
Commercial Refrigeration from other brands with the most of the same figures in their manuals. Values as printed in each manual.
| Kelvinator KCHRI27R1DFE | Other Commercial Refrigerator | Polar UA001-A | Gram Commercial Refrigerator | |
|---|---|---|---|---|
| Fridge adjustment range | 34 °F to 38 °F (1 °C, 3 °C) | 34 °F to 38 °F (1 °C, 3 °C) | -2 °C to +4 °C (28 °F, 39 °F) | 2 to 12 °C (36 to 54 °F) |
| Freezer adjustment range | -7 to -3 °F (-22 to -19 °C) | -7°Fto -1 °F (-22 °C, -18 °C) | -18 °C to -22 °C (0 °F, -8 °F) | -10 to -22 °C (14 to -8 °F) |
| Wait before use | at least 24 hours | at least 24 hours | about 12 hours | at least 2 hours |
| Clearance above | 12” | 12" (30.5 cm) | 5cm | 250 mm (9.8 in) |
Similar Kelvinator commercial refrigeration
| Kelvinator KCHGM48RModel family KCH | Owner's Manual | 34 pages |
|---|---|---|
| Kelvinator KCCF073WS | Owner's Manual | 20 pages |