Key numbers from this manual
As printed in the manual, with metric and US units side by side. The typical range comes from all commercial refrigerator manuals on this site that print the same figure.
| Fridge factory setting | 5 °C (41 °F) warmer than mostRefrigerators with extended temperature range (M)Typical for commercial refrigeration: 35 to 38 °F (2 to 3 °C) | p. 36 |
|---|---|---|
| Fridge adjustment range | 2 to 12 °C (36 to 54 °F)Refrigerators (R and GR)-5 to 12 °C (23 to 54 °F)Refrigerators with extended temperature range (M)Typical for commercial refrigeration: 34 to 45 °F (1 to 7 °C) | p. 36 |
| Freezer factory setting | -18 °C (0 °F)Freezers (F)Typical for commercial refrigeration: -4 to 0 °F (-20 to -18 °C) | p. 36 |
| Freezer adjustment range | -10 to -22 °C (14 to -8 °F)Freezers (F)Typical for commercial refrigeration: -8 to 3 °F (-22 to -16 °C) | p. 36 |
| Wait before use | at least 2 hoursAfter horizontal transport, before starting | p. 29 |
| Door-open alarm after | more than 2 minutesDoor remains openTypical for commercial refrigeration: 1 to 5 minutes | p. 39 |
| Clearance above | 250 mm (9.8 in)Minimum clearance above the cabinetTypical for commercial refrigeration: 0 to 12 in (0 to 30.5 cm) | p. 30 |
| Clearance at the sides | 20 mm (0.8 in)Minimum clearance at the sidesTypical for commercial refrigeration: 0 to 4 in (0 to 10.2 cm) | p. 30 |
| Clearance behind | max. 75 mm (3 in)Distance from the wallTypical for commercial refrigeration: 1 to 4 in (2.5 to 10.2 cm) | p. 30 |
| Defrost | automatically performed 4 times every 24 hoursCOMPACT R/C, GR, and COMPACT FautomaticCOMPACT F, 4 times every 24 hours | p. 39 |
| Room temperature range | +16C and +40 °C (104 °F)Operating ambient temperatureTypical for commercial refrigeration: 60 to 100 °F (16 to 38 °C) | p. 29 |
Gram Commercial Refrigerator questions
Answers taken from this manual. Each one links to the page it comes from.
What should I do about water or ice inside the back wall or bottom?
What clearances does the refrigerator need during installation?
Leave at least 250 mm above, 20 mm at the sides, and no more than 75 mm from the wall.
| Location | Required clearance |
|---|---|
| Above cabinet | 250 mm |
| Cabinet sides | 20 mm |
| From wall | Maximum 75 mm |
Other brands: Other 12" (30.5 cm) · Summit 4“(102mm) · True 1" (25.4 mm) Compare all
Manual: page 30
Does a glass-door cabinet need to be fastened?
Yes. Fasten it to a stable surface so it does not tilt when the door is open.
Manual: page 31
Can I reset a present temperature alarm?
What do E1 and E2 mean on the display?
- E1 means the room sensor is defective. Monitor temperature and request service assistance immediately.
- E2 means the evaporator sensor is defective. Defrosting becomes time-based in freezers; request service assistance.
Manual: page 39
What do the Ah and AL temperature alarm codes mean?
Ah and AL identify high- and low-temperature alarms, shown alternately with the current temperature.
| Code | Meaning |
|---|---|
| Ah | High-temperature alarm |
| AL | Low-temperature alarm |
Manual: page 38
What is this refrigerator intended for?
Foodstuffs in non-household settings, not customer display or access; do not chill down or freeze hot or fresh food.
Manual: page 27
Error codes in this manual
| Code | Meaning | What to do | |
|---|---|---|---|
| Ah | High temperature alarm. | p. 21 | |
| AL | Low temperature alarm. | p. 21 | |
| d | Dry cooling is activated. | p. 21 | |
| E1 | The room temperature sensor is defective. | Monitor the temperature and request service immediately. | p. 21 |
| E2 | The evaporator sensor is defective. | Request service assistance; defrosting becomes time based. | p. 21 |
| OP | The door is open, or has been open over two minutes. | Close the door. | p. 21 |
Gram Commercial Refrigerator compared with other brands
Commercial Refrigeration from other brands with the most of the same figures in their manuals. Values as printed in each manual.
| Gram Commercial Refrigerator | Other Commercial Refrigerator | Hoshizaki Commercial Refrigerator | Summit FF64BCSS | |
|---|---|---|---|---|
| Fridge factory setting | 5 °C (41 °F) | 34 °F to 38 °F (1 °C, 3 °C) | 36 °F (2 °C) | 38 °F/3 °C |
| Fridge adjustment range | 2 to 12 °C (36 to 54 °F) | 34 °F to 38 °F (1 °C, 3 °C) | 36 °F and 50 °F (2 °C and 10 °C) | 36 °F/2 °C to 43 °F/6 °C |
| Freezer factory setting | -18 °C (0 °F) | -7°Fto -1 °F (-22 °C, -18 °C) | -3 °F (-19 °C) | 0 °F/-18 °C |
| Freezer adjustment range | -10 to -22 °C (14 to -8 °F) | -7°Fto -1 °F (-22 °C, -18 °C) | -10 °F and 25 °F (-23 °C and -4 °C) | -11 °F/-24 °C to 11 °F/-12 °C |
| Wait before use | at least 2 hours | at least 24 hours | · | · |
| Door-open alarm after | more than 2 minutes | · | 3 minutes | · |
| Clearance above | 250 mm (9.8 in) | 12" (30.5 cm) | 10" (25 cm) | 4“(102mm) |
Similar Gram commercial refrigeration
| Gram Commercial Refrigeration Instruction Manual | Instruction Manual | 154 pages |
|---|---|---|
| Gram Commercial Refrigeration User Manual | User Manual | 140 pages |
| Gram IO-REF-1455 | Instruction Manual | 132 pages |
| Gram Commercial Refrigeration Instruction Manual | Instruction Manual | 131 pages |
| Gram IO-REF-1453 | Instruction Manual | 124 pages |
| Gram IO-REF-1421 | Instruction Manual | 120 pages |
| Gram IO-REF-1419 | Operating Instructions | 120 pages |
| Gram 6C1854 | Operating Instructions | 120 pages |