What defrost schedule does the timer use?

The factory program uses four start times, each with a 45-minute duration.

Start timeDuration
4:00AM45 minutes
10:00AM45 minutes
4:00PM45 minutes
10:00PM45 minutes

Manual: page 22

What happens when electric defrost finishes?

At approximately 55 °F, the termination thermostat stops the defrost heaters. The timer then restores the temperature-control circuit.

Manual: page 22

How do I mount the condensing unit base?
  1. Fasten the base to pads or structural rails with properly sized bolts.
  2. Support the center of the condensing unit properly.

Manual: page 5

How often should I check evaporator defrosting and clean its coil?

Monthly, check evaporator defrosting and clean the coil and drain pan.

Manual: page 23

What can happen if the condenser coil is not kept clean?

Reduced condenser airflow can cause poor performance and premature compressor failure.

Manual: page 23

Similar Manitowoc walk-in coolers & cold rooms

Manitowoc Foodservice Walk-In DivisionInstruction Manual40 pages
Manitowoc Foodservice Walk-In DivisionInstruction Manual40 pages
Manitowoc Foodservice Walk-In DivisionUser Manual37 pages
Manitowoc Foodservice Walk-In DivisionInstruction Manual24 pages
Manitowoc Foodservice Walk-In DivisionOperating Instructions16 pages
Manitowoc Foodservice Walk-In DivisionOperating Instructions14 pages
All Manitowoc walk-in coolers & cold rooms →