Manitowoc Walk-in CoolerWalk-in CoolerShares large sectionsOperating Instructions · 32 pages

Key numbers from this manual

As printed in the manual, with metric and US units side by side. The typical range comes from all walk-in cooler manuals on this site that print the same figure.

Clearance at the sidesa minimum distance equal to the total width of the condensing unitall sides of the condensing unit from another unit, wall, or obstructionequal to or greater than the coil heightall sides of the evaporator coilp. 5 p. 6

Manitowoc Walk-in Cooler questions

Answers taken from this manual. Each one links to the page it comes from.

Why is water or ice collecting in the drain pan?
  • The unit is not pitched properly. Check and adjust it.
  • The drain line is plugged. Clean the drain line.
  • The drain line heater is defective. Replace the heater.
  • The timer or thermostat is defective. Replace the defective component.

Manual: page 31

Why won't the compressor run?
  • Main switch open. Close the switch.
  • No cooling required. Wait until cooling is required.
  • Thermal overloads tripped. They reset automatically; check the unit when it returns to operation.

Manual: page 32

Why is the walk-in temperature too high?
  • Unit in defrost cycle. Wait for the cycle to finish.
  • Thermostat set too high. Adjust the thermostat.
  • Coil iced up. Manually defrost the coil and check defrost controls.

Manual: page 31

How much space should surround the condensing unit?

At least the condensing unit’s total width must separate each side from another unit, wall, or obstruction.

Manual: page 5

How much clearance does the evaporator coil need?

Leave clearance equal to or greater than the coil height on every side for airflow and service access.

Manual: page 6

How often does an Air Defrost evaporator run its default defrost cycle?

Every 6 hours for 30 minutes is the default for Air Defrost model evaporators using P/N 550005663.

Manual: page 24

What do the thermostat’s alarm settings mean?

These thermostat entries identify the high alarm, low alarm, and temperature alarm delay settings.

DisplayMeaning
HAOHigh Alarm Offset
LAOLow Alarm Offset
tAdTemperature Alarm Delay

Manual: page 26

Error codes in this manual

CodeMeaningWhat to do
HAOHigh Alarm Offsetp. 26
LAOLow Alarm Offsetp. 26
tAdTemperature Alarm Delayp. 26
All Manitowoc error codes →

Similar Manitowoc walk-in coolers & cold rooms

Manitowoc Foodservice Walk-In DivisionOperating Instructions43 pages
Manitowoc Foodservice Walk-In DivisionOperating Instructions43 pages
Manitowoc Foodservice Walk-In DivisionInstruction Manual40 pages
Manitowoc Foodservice Walk-In DivisionInstruction Manual40 pages
Manitowoc Foodservice Walk-In DivisionUser Manual37 pages
Manitowoc Foodservice Walk-In DivisionOperating Instructions32 pages
Manitowoc Foodservice Walk-In DivisionInstruction Manual24 pages
Manitowoc Foodservice Walk-In DivisionOperating Instructions16 pages
All Manitowoc walk-in coolers & cold rooms →