Key numbers from this manual

As printed in the manual, with metric and US units side by side. The typical range comes from all refrigerator manuals on this site that print the same figure.

Fridge factory setting5 CFactory chamber temperature settingTypical for refrigerators: 37 to 39 °F (3 to 4 °C)p. 17
Fridge adjustment rangebetween 2 C and 23 CChamber temperature settingTypical for refrigerators: 36 to 46 °F (2 to 8 °C)p. 17
Door-open alarm after2 minutesFactory setting; adjustable from 1 to 15 minutesTypical for refrigerators: 1 to 5 minutesp. 19
DefrostautomaticRoutine defrostingp. 21
Room temperature rangebetween -5 and +35 CTypical for refrigerators: 50 to 100 °F (10 to 38 °C)p. 13

Panasonic MPR-721 questions

Answers taken from this manual. Each one links to the page it comes from.

What chamber temperatures can I set?

The setting range is between 2 C and 23 C, with a 5 C factory setting. Below 3 C, partial freezing may occur.

Manual: page 17

How much ventilation space does the refrigerator need?

Leave at least 10 cm around the unit for ventilation.

Manual: page 13

What ambient temperature range is allowed?

Between -5 and +35 C is the allowable ambient temperature.

Manual: page 13

What should I check if the refrigerator is not cold enough because of the door seal?

Check that the door is securely closed and that the door seal is not damaged or obstructed by foreign substance. If cooling does not recover after these checks, contact the sales representative or agent.

Manual: page 25

Do I need to defrost the refrigerator manually?

No routine defrosting is needed because the unit defrosts automatically.

Manual: page 21

Why is frost still forming inside the refrigerator?

High humidity or much damp product can exceed normal cycle defrosting; start a Forced defrost cycle. Normal operation resumes afterward.

Manual: page 21

What do E01 through E05 mean?

They indicate disconnected or short-circuited temperature sensors.

CodeMeaningDisplay
E01Thermal sensor disconnectedE01 and 50 C, or -50 C
E02Thermal sensor short-circuitedE02 and 50 C, or -50 C
E03Defrost sensor disconnectedE03 and chamber temperature
E04Defrost sensor short-circuitedE04 and chamber temperature
E05Compressor sensor disconnectedE05 and chamber temperature

Manual: page 22

Error codes in this manual

CodeMeaningWhat to do
E01Thermal sensor is disconnected.p. 22
E02Thermal sensor is short circuited.p. 22
E03Defrost sensor is disconnected.p. 22
E04Defrost sensor is short circuited.p. 22
E05Compressor sensor is disconnected.p. 22
E06Compressor sensor is short circuited.p. 22
E07Ambient temperature sensor is disconnected.p. 22
E08Ambient temperature sensor is short circuited.p. 22
E09Battery setting is incomplete after installation.Turn off the battery switch, perform the setting, then turn it on again.p. 22
E10Condenser temperature is abnormal because the compressor cooling fan failed.p. 22
All Panasonic error codes →

Panasonic MPR-721 compared with other brands

Refrigerators from other brands with the most of the same figures in their manuals. Values as printed in each manual.

Panasonic MPR-721Samsung RR39A7463APMarvel 80RDESummit ASDR1524
Fridge factory setting5 C3 °C (37 °F)38 °F (3 °C)38 °F/3 °C
Fridge adjustment rangebetween 2 C and 23 C7 °C and 1 °C (45 °F, 34 °F)33° to 47 °F (8 °C)36 °F/2 °C to 43 °F/6 °C
Door-open alarm after2 minutesmore than 2 minutesover 5 minutesmore than 60 seconds
Room temperature rangebetween -5 and +35 Cbetween 10 °C and 43 °C (50 °F, 109 °F)55°, 80 °F (27 °C)above 44 °F (7 °C) and below 90 °F (32 °C)

Similar Panasonic refrigerators

Panasonic MPR-215FModel family MPROperating Instructions46 pages
Panasonic MDF-C8V1Service Manual73 pages
Panasonic NR-XY680YOperating Instructions104 pages
Panasonic NR-F603GTOperating Instructions80 pages
Panasonic Click here to download the manualInstruction Manual68 pages
Panasonic NIR-C371Operating Instructions56 pages
Panasonic NR-BW530HOperating Instructions56 pages
Panasonic NR-BX421Operating Instructions36 pages
All Panasonic refrigerators →