Key numbers from this manual

As printed in the manual, with metric and US units side by side. The typical range comes from all commercial refrigerator manuals on this site that print the same figure.

Fridge adjustment range1 to 9 (or 1 to 7) plus “OFF” or “O”Temperature control dialTypical for commercial refrigeration: 34 to 45 °F (1 to 7 °C)p. 17
Defrostautomatic defrostcooling deck based HC coolersp. 16

QBD CD10-58-HC questions

Answers taken from this manual. Each one links to the page it comes from.

What should I do if the display shows OFF and the cooler is not cooling?

The cold control is OFF. The compressor and condenser fan are disabled, but evaporator motor power remains live. Hold COLDER for 3 seconds to turn it ON.

Manual: page 17

Why is water leaking from the cooler?
  • Blocked drain. Clear the blocked drain.
  • Door not sealed properly. Repair or replace door gaskets, then realign and seal the doors.
  • Defective cooling-deck gasket. Repair or seal air leaks, then replace the damaged gasket.

Manual: page 30

How do I fix a cooler door that is not sealing?

Repair or replace the door gasket, then realign and reseal the doors. An improperly sealed door or top door seal is listed as a cause.

Manual: page 30

How do I start or stop a defrost cycle?
  1. Hold the WARMER button for 3 seconds to start defrosting.
  2. The controller exits defrost automatically after 20 minutes.
  3. To stop it sooner, hold the WARMER button for 3 seconds.

Manual: page 16

How often does automatic defrost run, and what happens during it?

Every 6 hours, the cycle runs for 20 minutes; evaporator fan motors run 4 minutes and stop 1 minute during the cycle.

Manual: page 17

Can I power the cooler with an extension cord or power bar?

No. Use the cooler’s own dedicated electrical circuit, not an extension cord, power bar, or wiring device adapter.

Manual: page 11

What should I check before plugging in or switching on the cooler?

Check for a Hydrocarbon leak with a certified hydrocarbon leak detector before plugging in, unplugging, or switching power on.

Manual: page 12