Key numbers from this manual

As printed in the manual, with metric and US units side by side. The typical range comes from all commercial refrigerator manuals on this site that print the same figure.

Fridge factory setting38 °F (3 °C)Factory presetTypical for commercial refrigeration: 35 to 38 °F (2 to 3 °C)p. 9
Fridge adjustment range36 °F to 43 °F (2 °C, 6 °C)Temperature controlTypical for commercial refrigeration: 34 to 45 °F (1 to 7 °C)p. 9
Door-open alarm after60 secondswhen the appliance door remains openTypical for commercial refrigeration: 1 to 5 minutesp. 13
Defrostautomaticnormal operating conditionsautomaticallynormal operating conditionsp. 10
Room temperature rangeabove 60 °F (16 °C) and below 90 °F (32 °C)installation area72º and 78ºF (23º-26ºC)Recommended installation ambient temperatureTypical for commercial refrigeration: 60 to 100 °F (16 to 38 °C)p. 4 p. 8
Power outagea few hoursmost power failuresp. 11
Sabbath modeYesSummit SCR1156p. 10

Summit SCR1156 questions

Answers taken from this manual. Each one links to the page it comes from.

How do I change the temperature setting?
  1. Touch UP or DOWN once to show the previous temperature setting.
  2. Touch UP to raise the setting 1 °C/1ºF per press.
  3. Touch DOWN to lower the setting 1 °C/1ºF per press.
  4. Wait 5 seconds; the display returns to the unit’s interior temperature.

Manual: page 8, page 9

Why might the selected temperature not be reached?

Keep the appliance in an ambient temperature of 72º to 78ºF (23º to 26ºC). Temperatures outside this range may affect performance. The 36º to 43ºF (2º to 6ºC) range may not be reached.

Manual: page 8

Why won't the refrigerator run?
  • No power connection. Connect the appliance to a power source.
  • The appliance is turned off. Switch on the appliance.
  • Tripped breaker or blown fuse. Switch on the breaker or replace the fuse.

Manual: page 12

How does defrosting work, and when is manual defrosting needed?

Automatic defrosting occurs during normal operation. If frost remains after 24 hours of repeated opening in high heat or humidity, manual defrosting is needed.

Manual: page 10

What happens to the temperature setting after a power interruption?

The previous temperature setting returns when power is restored; limiting door openings helps protect the temperature during an outage.

Manual: page 10, page 11

Why will the refrigerator not turn on?
  • No power connection. Connect the appliance.
  • The appliance is turned off. Switch it on.
  • A circuit breaker tripped or fuse blew. Switch on the circuit breaker or replace the fuse.

Manual: page 12

Why is the refrigerator making rattling, gurgling, popping, or crackling sounds?

Normal refrigerant flow can cause rattling and gurgling, while temperature-related wall movement can cause popping and crackling; level the appliance with its adjustable feet.

Manual: page 13

Why does the alarm sound while the temperature display flashes?
  • Door open longer than 60 seconds. Close the door.
  • Temperature moved beyond the set value. Reduce frequent openings, clear blocked or dusty ventilation, and wait for recovery.
  • Power interruption or many newly added bottles. Wait until the set temperature is reached.

Manual: page 13

Summit SCR1156 compared with other brands

Commercial Refrigeration from other brands with the most of the same figures in their manuals. Values as printed in each manual.

Summit SCR1156Turbo Air TGM-10SD-NGram Commercial RefrigeratorHoshizaki Commercial Refrigerator
Fridge factory setting38 °F (3 °C)37℉(3℃)5 °C (41 °F)36 °F (2 °C)
Fridge adjustment range36 °F to 43 °F (2 °C, 6 °C)From '50℉' to '30℉'('10℃' to '-1℃')2 to 12 °C (36 to 54 °F)36 °F and 50 °F (2 °C and 10 °C)
Door-open alarm after60 seconds30 secondsmore than 2 minutes3 minutes
Room temperature rangeabove 60 °F (16 °C) and below 90 °F (32 °C)50 °F (10 °C) to 100 °F (38 °C)+16C and +40 °C (104 °F)45 °F to 100 °F (7 °C to 38 °C)

Similar Summit commercial refrigeration

Summit SCR610BLModel family SCRUse & Care Guide24 pages
Summit SPR627OSUse & Care Guide32 pages
Summit SBC56GBIADAOperating Instructions28 pages
Summit SBC56GBIADAOperating Instructions21 pages
Summit FF64BCSSUse & Care Guide32 pages
Summit FF64BCSSUse & Care Guide16 pages
Summit AL57GOperating Instructions14 pages
All Summit commercial refrigeration →